Manuale d’uso / di manutenzione del prodotto HE Plus 1400 del fabbricante Trion
Vai alla pagina of 14
ELECTRONIC AIR CLEANER LIMITED THREE-YEAR W ARRANTY This limited warranty covers T rion Residential T ype Electronic Air Cleaners, excluding ductwork, wiring and installation. T rion warrants that all new T rion Electronic Residential Air Cleaners are free from defects in material and workmanship under normal, noncommercial use and service.
Power T ray Assembly 120/50-60/1 Power T ray Assembly 240/50-60/1 High Frequency Power Supply* Electronic Air Flow Sensor* On/Off switch* Interlock Switch* Cabinet Assembly Pre-Filter (2 req.) Cell, Ionizing-Collecting (2 req.) Ionizing Wire Assembly Front Panel Assembly Contact Board Assembly (2 req.
10. If no voltage is present, remove the second cell. Install cell number one and measure voltage as described in step #7. If voltage is present, the second cell, which is now out of the cabinet, is shorted. Refer to COMMON TROUBLESHOOTING TECHNIQUES (pg.
SECONDAR Y CIRCUIT POWER SUPPL Y If the Red CELL ENERGIZED light remains out with the Ionizing-Collecting Cells removed from the cabinet, the power supply is defective. Specific problems in the Power T ray Assembly can be isolated by using a Multimeter and High V oltage Probe to check the output voltages.
SECONDAR Y CIRCUIT IONIZING-COLLECTING CELL The cells are electrically energized through a contact terminal located at the top center of each cell. The ionizing wires and alternating collector plates are electrically charged while the interleaving plates are grounded.
PRIMAR Y CIRCUIT WITH HV AC SYSTEM BLOWER OPERA TING • If there is no supply line voltage at the transformer input connections, correct the fault at the dedicated power source or HV AC system power source.
TROUBLESHOOTING W ARNING: • These procedures must be performed by a qualified HV AC technician or electrician. • Risk of personal injury or death could occur by attempting to troubleshoot or r epair this unit by untrained persons. • Exercise the usual pr ecautions when working with high voltage.
SYSTEM CHECKOUT W ARNING: The following procedur es must be conducted by a qualified HV AC contractor or repair person ONL Y . These procedur es will expose hazardous electrically energized charged components. Disconnect power between checks and proceed car efully .
ELECTRICAL INST ALLA TION CAUTION : If the Electronic Air Cleaner is wir ed directly to the integrated accessory control on the furnace, it is imperative that the ampere rating of the contr ol be sufficient to handle the curr ent requir ed by the air cleaner .
NOTE: The following is a typical installation of the air cleaner on a highboy furnace. Y ou may have to alter the installation to fit your particular application. 1. Locate the cabinet in the cold air return duct such that all of the return air flows through the unit.
INST ALLA TION CAUTION: Only a trained, experienced servicer should install this Electronic Air Cleaner . The Front Panel Assembly , Power T ray Assembly , Ionizing-Collecting Cells and Pre-filters should be r emoved befor e installation. T o remove the Power T ray Assembly , remove the two (2) screws fr om inside the top front of the cabinet.
Installation 15 EAC20002025 EAC14001625 EAC14002020 Unit Dimensions 10 For Qualified HV AC Installer Only TYPICAL MOUNTING POSITIONS (Air cleaner shown shaded in illustrations) Horizontal Furnace – Mounted vertically in return duct as close to the furnace as possible.
LOCA TION SELECTION Remember to select a location that is readily accessible for periodic inspection and cleaning of the the Pre- filters and Ionizing-Collecting Cells. Allow a minimum of 24” clearance in front and 12” clearance above the air cleaner for component removal and service space.
Atomizing Humidifiers If an atomizing humidifier is mounted upstream of the air cleaner: 1. Mount the humidifier as far upstream in the ductwork as possible. A distance of at least 10 feet is recommended to reduce the possibility of excessive arcing as water droplets pass through the Electronic Air Cleaner .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Trion HE Plus 1400 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Trion HE Plus 1400 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Trion HE Plus 1400 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Trion HE Plus 1400 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Trion HE Plus 1400, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Trion HE Plus 1400.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Trion HE Plus 1400. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Trion HE Plus 1400 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.