Air Boss MP 600M Vertical Air Flow Mist Precipitator Installation Operation Service Please read these instructions carefully for trouble free operation and to get the mo st out of your purchase. For further info rmation concern ing this pro ject, con tact your local Tr ion representative.
2 DESCRIPTION The Trion MP 600M air cleane r is designed to capture machine tool fluids, metal dust and sm oke for clean air filtration. It can be mounted to a wall, frame, platfo rm, or directly on the machine tool. Mist, dust, and smoke are drawn from each machine through an external duct into the air cleaner.
3 Figure 1 - MP 600M High Static SPECIFICATIONS STANDARD OPTIONAL MP600M and High Static MP 600M Voltage 115 208-230 208-230/460 575 115/230 Phase 1 1 3 3 1 HZ 60 60 60 60 60 AMPS 17 9.4-8.5 4.9-4.6/2.3 1.9 8.0-4.0 Motor ½ hp 1 ½ hp 1 ½ hp 1 ½ hp ½ hp CFM 600 600 600 600 600 Shipping Weight 175 lbs 225 lbs.
4 Figure 2 – Dimension and Access Data GENERAL SAFETY INFORMATION WARNING: RISK OF ELECTRIC SHOCK These serving instruction s are for use by qualified personnel only, To redu ce the risk of electric shock, do not perform any servicing ot her than that contained in the operating instructions unl ess you are qualified to do so.
5 CAUTION: When using flex duct connections with other than straight runs of duct, 45 degree elbows shoul d be used to connect ducting to flang ed collars to maximize air flow.
6 Figure 4 - MP 600M Inlet Plenum and Stand Options.
7 Figure 5 – Wiring Diagrams for Model MP 600M.
8 Figure 6 – Wiring Diagram.
9 Figure 6A – Motor Wiring Diagram.
10 The MP600M is wired directly from the power source with 20 amps minimum, se rvice utilizing 3 wire grounded cable, (115-208-2 30-460-575/60/3) for single 208- 230/60/1, phase service and 4 wi re grounded cable for 3 phase service, routed through ap propriate conduit (See figure 5 wiring diagram).
11 A. Thoroughly inspect the main and pre- filter for holes, tears or any other condition that might allow air to leak through or around the filter. Re place the filters if any damage is found. B. Inspect the cabinet. Remove all foreign debris and dirt accumulation insi de the cabinet.
12 Figure 7 – MP 600M Unit Assembly.
13 Figure 7A – Unit Assembly Parts List MP 600M MP 600M HS Qty Qty Item Part No. Description Rem arks 1 1 1 353613-001 Cabinet Assembly 1 1 2 354477-001 Access Door 1 1 3 253619-001 Blower Housing C.
14 Figure 8 – Filter Locking Mechanism - Access opening increased 3.5 ” height - 16 GA tapered filter retainer welded in door and ca binet rear - As door closes, filter gasket is compre ssed and s.
15 Figure 9 – System Performance Curv es (without Filters) Flow – CFM @ 60 Hz Added Static @ Filter 600 CFM 1000 m 3 /hr Filter Inches W.C. Pascals 99.97% DOP HEPA 1.00 250 95% DOP 0.35 87 90-95% ASHRAE 0.20 50 80-85% ASHRAE 0.15 37 60-65% ASHRAE 0.
WARRANTY All Trion air cleaners are warranted fo r component failure and workmanship for a period of three years after purchase. Do not return defective pa rts without prior permission from the factory.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Trion 600M è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Trion 600M - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Trion 600M imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Trion 600M ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Trion 600M, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Trion 600M.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Trion 600M. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Trion 600M insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.