TIC-LF654L Introduction The electromagnetic flowmeter uses Faraday’s Law of electromagnetic induction to measure the process flow. The device consists of two units: a detector, through which the flu.
TIC-LF654L 2 Fluid conductivity: 3µS/cm minim um Fluid temperature: -4 to 248 °F ( - 20 to +120 °C): PFA lined flowmeter -4 to 140 °F ( - 20 to +60 °C): Polyurethane lined flowmeter 23 to 176 °F.
TIC-LF654L 3 Model LF620 and LF622 converters Input signals Analog signal — the voltage signal from detector, proportional to process flow rate (for LF622 separate type converter). Digital input DI Signal type: 20 to 30Vdc voltage signal Input resistance: 2.
TIC-LF654L 4 LCD display: Full dot-matrix 128×128 dot LCD displ ay (back–light provided) A parameter change will rotate the display. Parameter settings — Parameters can be set as follows: • IR Swit ches : Three key switches are provided to set configuration parameters.
TIC-LF654L 5 Installation Dimensions Note1: Eye bolts ar e provided at the top f or flowmeters sized 8" (200 mm) or above, and further, a roll-p revention base is provided for flowmeters sized 10" (250mm) or larger. Note2: Cable glands are not provided for LF654 of cFMus approved type.
TIC-LF654L 6 ASME B 16.5 class 150 dimensions: EN 1092-1 PN16 dimensions: Meter size (mm) L1 (mm) L2 (mm) L3 (mm) No. of bolts Weight (kg) 15 200 203 251 4 a p p r ox . 6 . 0 25 200 209 272 4 a p p r ox . 7 . 5 32 200 217 285 4 a p p r ox . 1 0 . 0 40 200 218 288 4 a p p r ox .
TIC-LF654L 7 ASME B 16.5 class 150 dimensions: Meter size (inch) L1 (inch) L2 (inch) L3 (inch) No. of bolts Weight (lbs) 1/2 5.51 6.77 8.54 4 appr ox. 9.0 1 6.30 7.01 9.13 4 approx. 14.0 1-1/4 7.87 7.32 9.65 4 approx. 18.0 1-1/2 6.69 7.36 9.88 4 approx.
TIC-LF654L 8 ASME B 16.5 class 150 dimensions: Meter size (inch) L1 (inch) L2 (inch) L3 (inch) No. of bolts Weight (lbs) 1/2 7.90 6.77 8.54 4 approx. 9.0 1 7.90 7.01 9.13 4 approx. 14.0 1-1/4 7.90 7.32 9.65 4 approx. 18.0 1-1/2 7.90 7.36 9.88 4 approx.
TIC-LF654L 9 Figure 7. Separate type converter LF622 and LF622F External Connections ● Combined type LF650/LF620 flowme ter and LF654/LF620F flowmeters Grounding w it h 100 Ω or les s ground res is t anc e I ns t ru m ent panel : Ordered s eparat el y I / O c able Ⅳ wi r e 5 .
TIC-LF654L 10 ● Separate type LF650/LF622 flowmeter and LF654/LF622F fl owmeter G roun di ng w it h 100 Ω or l es s ground resis t anc e I ns t rum e n t pane l : O r d ere d s epa ra t e l y I / O c able G round ing w it h 1 0 0 Ω or l es s ground res is t anc e Ⅳ w ire 5.
TIC-LF654L 11 Wiring Precautions (1) Explosion proof type flowmeters are not provided with cable glands. Refer to the part Cable connection port at detector and converter. (2) Connect the grounding wire (IV wire 5.5mm ² or more) to a good earth ground (100 or less ground resistance).
TIC-LF654L 12 T able 3. Flow Rate and Flow velocity (SI unit) Unit: m 3 /h Size (mm) Flow rate 0.1 m/s 0.3 m/s 1.0 m/s 3.0 m/s 12 m/s 15 0.06362 0.1908 0.6361 1.908 7.634 25 0.1767 0.5301 1.767 5.301 21.21 32 0.2895 0.8686 2.895 8.686 34.74 40 0.4523 1.
TIC-LF654L 14 T able 4. Specification Code (Flange type detector LF654 Series) Model Spec ification Code Descripti on Detector ca tegory 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Gr.
TIC-LF654L 15 T able 5. Specification Code for co nverters Model Spec ification Code Contents LF620 type LF622 type 1 2 3 4 5 6 7 8 9 10 1 1 12 13 14 L F 6 2 Electromagnetic flowmeter converter 0 Comb.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Toshiba LF654 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Toshiba LF654 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Toshiba LF654 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Toshiba LF654 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Toshiba LF654, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Toshiba LF654.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Toshiba LF654. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Toshiba LF654 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.