T OC 3.0 T able of Contents Gener al Categories 4.0 - Installation, General Calibration & Seed Calibration Calibr ation 5.0 - Calibration & P riming the Pump Oper ation 6.0 - Operation Appendix 7.0 - Maintenance 8.0 - Service T ips, Pump Checklist & T roubleshooting 10.
4.0 General Introduction General Calibration The CF-80 seed treater can be easily calibrated. Determine the type of seed to be treated. Although the CF-80 can treat up to 80 bushels per hour of soybean seed, other types of seed may not ow through the treater as freely; therefore capacity may vary .
Calibration 5.0 Calibration & Pump P riming 1. R ead the entire chemical label and MSDS to make sure you under stand the usage and rates to be applied. T ake special note whether the recommended application rate of the chemical is given in uid ounces per bushel or in uid ounces per cwt.
6.0 Calibration Calibration & Pump P riming If more than the required volume of chemical is obtained, adjust the speed control knob to a lower setting and rerun the calibration check. Continue this operation until the proper rates are being measured.
Maintenance 7.0 Maintenance When you are nished treating seed, disconnect the discharge tubing from the elbow tting and place it into your original chemical container .
8.0 Service Service T ips 1. Make sure ball valve is in ON position. 2. Check tightness of intake line tting - use pliers if necessary . Make sure there are no air bubbles in the line. 3. Check discharge hose for any chemical buildup. 4. Make sure the pump hose is in the correct position.
Appendix.
10.0 Guidelines GUIDELINES FOR HANDLING SEED-APPLIED PRODUCTS AND RECOMMENDED EQUIPMENT INSPECTION AND MAINTENANCE PROCEDURES The following are general recommendations for handling seed-applied products, equipment inspection and maintenance on most Gustafson application equipment used in commercial treating facilities.
Guidelines 11.0 Gener al Equipment • Check lters daily at least once. Clean rinse off as necessary . The lter assemblies are intended to keep agglomerates, plant debris and other foreign substances from going through the system and plugging lines.
12.0 W arranty LIMITED W ARRANTY , LIMIT A TION OF LIABILITY & CLAIMS Bayer CropScience warrants that the Gustafson application equipment shipped hereunder shall be free of defects in materials or work- manship for a period of one (1) year from the date of delivery .
This page intentionally left blank.
Bayer CropScience 4895 12th Avenue East Shakopee, Minnesota, 55379 USA www .bayercropscienceus.com.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Bayer HealthCare CF-80 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Bayer HealthCare CF-80 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Bayer HealthCare CF-80 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Bayer HealthCare CF-80 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Bayer HealthCare CF-80, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Bayer HealthCare CF-80.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Bayer HealthCare CF-80. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Bayer HealthCare CF-80 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.