Manuale d’uso / di manutenzione del prodotto C300 NP del fabbricante Taylor
Vai alla pagina of 49
Model C3 00 NP No n -Pr essurized Slu sh F reezer Original Ope ra ting Instruc tions 055072NP 9/22/ 06 (Or igi nal Publ icat i on) (Up da ted 5 /6/1 1 ).
Com plete thi s page for qui ck r efer enc e when ser vi ce is r equir ed: Taylor Distributor: Address: Phone: Fax: E-mai l: Serv ice: Par ts: Date of Installation: Infor ma tion found on the data lab.
Model C3 0 0 NP Table of Cont ent s T able of Contents Section 1 To the Installer 1 ............................................ Air Cool ed Units 1 ....................................................... Water Cooled R efrigeration Uni ts (Water Cool ed Units Onl y) 1 .
Table of Cont ent s Model C3 0 0 NP Table of Contents - P age 2 Sec tion 7 Impor tant: Oper ator Che ckli st 29 .............................. During Cl eaning and Sani tizing 29 ......................................... Troubleshooting Bacterial Count 29 .
1 Model C3 0 0 NP To the Insta ller 071010 Section 1 To the Installer The M odel C300NP is designed f or indoor us e only. DO NOT i n s t a l lt h em a c h i n ei na na r e a where a wat er jet c ould be used. F ailure t o follow this inst ruc tion may res ult in serious elect rical shoc k.
2 Model C3 0 0 NP To the Insta ller 110506 Electr ical Connections Each unit requir es one power s upply for each dat a label on the unit . Chec k the dat a label(s) on t he fr eezer f or branch c ircuit over curr ent prot ect ion or fuse, c ircuit am pacity , and other electric al specif icat ions.
3 Model C3 0 0 NP To the Opera tor 110506 Section 2 T o the Ope rator The f reezer you hav e purchased has been car efully engineered and manuf act ured to giv e you dependable operat ion. The M odel C300NP, when pr operly operat ed and cared f or, will produc e a consist ent qualit y produc t.
4 Model C3 0 0 NP Safety 110506 Section 3 Sa fety We, at T aylor Company, ar e concerned about the safet y of t he operat or when he or she c omes in contac t wit h the f reezer and it s part s.
5 Model C3 0 0 NP Safety CAUTI ON: Th i s un it i s pressu ri zed w hen in oper at ion. The cont rol swit ch mus t be in t he OF F position unt il t he unit is c ompletely ass embled. No part should ever be rem oved fr om t he machine while it is in operat ion.
6 Model C3 0 0 NP Op erato r Parts I den ti ficat io n Section 4 Operator Parts Ident ification 2 3 4 8 7 6 9 1 5 9 10 11 Figur e 3 ITE M DESCRIPTI ON PART NO. 1 PANEL-SI DE-LEFT 054676 2 PANEL-REAR 054672 3 PANEL-SI DE-RI GHT 054671 4 DISPLAY- LIGHTED 054683- 27 5 PANEL-FRONT- UPPER 054669 6 PANEL-FRONT- SHELL 054668 ITE M DESCRIPTI ON PART NO.
7 Mo del C300 NP Op erato r Parts I den ti ficat io n 081110 Beater Door A ssembly 2 1a 3 4 12 12 5 6 7 8 1b 1c 1d 1e 1i 11 1g 1f 1h 1j 9 10 5 Figur e 4 ITE M DESCRIPTI ON PART NO. 1 DOOR A.- SLUSH-SLFCLOSE- ICE BUSTER ( COMPLETE) X57323 (1a- 1j) 1a CAP A.
8 Model C3 0 0 NP Op erato r Parts I den ti ficat io n Accessor ies KA Y -5 Sanitizer/Cleaner ® CAUTION KEEP OUT OF REACH OF CHILDREN FOR INSTITUTIONAL USE ONLY 1 OZ (28.4 g) 2a 1 2b 2c 2d 5 4 3 0 4 8 2 6 0 048260 R Figur e 5 ITE M DESCRIPTI ON PART NO.
9 Model C3 00 NP Impor tant: To the Oper at or Section 5 Important: T o the Operator 4 3 5 1 2 6 PRIME AUTO ALARM SILENCER ALARM SILENCER OFF BEATER PRIME AUTO MENU OFF BEATER SELECT Figur e 6 ITE M D.
10 Model C3 00 NP Impor tant: T o the Ope rator Contr ol Switch The cont rol s witch is locat ed at t he top lef t c orner of the cont rol c hannel. W hen placed in the O N posit ion, allows SLUSHT ECH oper ation. Liquid Cr ystal Display The Liquid Cry st al Display (LCD) is loc ated on t he fr ont cont rol panel.
11 Model C3 00 NP Impor tant: To the Oper at or Oper ator Menu Tim eout If t he display is lef t in the oper ator menu or any of the oper ator m enu select ions, except f or Curr ent Conditions, t he display will return t o the system mode sc reen 60 seconds af ter t he last key press.
12 Model C3 00 NP Impor tant: T o the Ope rator 6. SYRUP PRESS LOW - W hen the sy rup out indicator display s a lack of syrup, the unit will enter a HOLD mode. At t his time, no ref rigerat ion or product f low fr om t he flow contr ol will be allowed.
13 Model C3 00 NP Impor tant: To the Oper at or Scree n C is SET CLOCK .U s e t h eA U T O( -- > )a n d OF F (< - -) k eys to place t he cursor under t he element t o be set (hour s, minut es, mont h, day, or ye ar). Us e the P RIME (+++) an d BEAT ER (- - -) keys t o increment or decrement t he value.
14 Model C3 00 NP Impor tant: T o the Ope rator The f ourt h feat ure will display t he Po wer S aver Mode, O FF, RES T, or S TANDBY st atus . If t he Power Sav er Mode is OF F, t he following scr een will be displayed. POWER SAVER MODE OFF SEL If a Power Sav er Mode is pr ogramm ed, one of t he following sc reens will appear .
15 Model C3 00 NP Impor tant: To the Oper at or Pres s the A UTO (- -> ) k ey to m ove to t he next scr een. T he next s creen will indicat e when t he fault was satis fied. FAULT HISTORY 2 10/25/ 06 14:06:19 RESTORED FROM FAULT PAGE 2 + + + - - - SEL Pre ss the MEN U (SEL ) key to retu rn to the OPERATOR MENU.
16 Model C3 00 NP Impor tant: T o the Ope rator CO 2 Out Indicator AUTO MODE AUTO OK SYRUP OK CO2-OUT WATER- OK On t he LCD, if t he word “O UT” appears next t o the word “C O 2 ” it indicat es a lack of CO 2 being supplied to t he fr eezer. T he product light will also illuminat e and a warning t one will sound.
17 Mo del C300 NP Op erati ng Pro cedu res Section 6 Operating Procedures The M odel C300NP cont ains two 7 quar t ( 6.6 lit er) freez ing cylinder s. The s yrup f low contr ol combines the t wo ingredient s of wat er and sy rup, and s ends this com bination t o the freez ing cylinder.
18 Model C3 00 NP Op erati ng Pro ced ures Step 3 Check the sc raper blade for any nic ks or signs of wear. I f any nicks are present, r eplace the blade. If the blade is in good c ondition, place t he clip ov er the blade. Pl ace the r ear scr aper blade and clip ov er the single holding pin on t he beater ( knife edge t o the outsi de).
19 Mo del C300 NP Op erati ng Pro cedu res Step 8 Inser t t he draw valv e into t he door. 1 1320 Figur e 13 Step 9 Ro tate the d ra w val ve so the g roov e on the to p of the draw valve is perpendic ular to t he door f ace.
20 Model C3 00 NP Op erati ng Pro ced ures Step 13 Place t he large rubber gask et int o the groov e on the back s ide of t he freez er door. 1 1324 Figur e 18 Step 14 Slide the whit e, plast ic f ront bear ing onto t he bearing hub, m aking cert ain that t he flanged end of t he bearing is r esting agains t t he fr eezer door.
21 Mo del C300 NP Op erati ng Pro cedu res Sani tizing Note: I f a unit is sanit ized, and will not be used f or an extended per iod of t ime, clean wat er should be used to f lush all s anitizer f rom t he lines. Remove t he water f rom all the lines and component s prior t o stor age of t he unit.
22 Model C3 00 NP Op erati ng Pro ced ures Pres s the M ENU (SE L) key . Move t he curs or under t he word “S ANIT I ZE” by press ing the O FF (< - - )key. RINSE / SANITI ZE RINSE SANITI ZE EXIT ----- <- - - -> SEL Step 7 Pres sing the M ENU (SE L) key will give you t he option f or sanit izing t he left f reezing cy linder.
23 Mo del C300 NP Op erati ng Pro cedu res Prim ing/Brixing Step 1 Connect t he sy rup line to t he Bag-in- Box ( BIB ) syrup. Step 2 Remo ve the drip tray, spla sh shie ld and th e lowe r fr ont panel t o gain access t o the sy rup sampling valve s. Step 3 Open t he prime plug.
24 Model C3 00 NP Op erati ng Pro ced ures Step 7 Pour t he product f rom t he syr up sampling v alve into a cup. Clos e the s yrup sam pling valve by t urning t he handle to t he cent er posit ion. Figur e 31 Step 8 Stir t he finished pr oduct . Pour a sm all amount of product over t he refr act ometer .
25 Mo del C300 NP Op erati ng Pro cedu res Step 11 Place a pail beneat h the door spout . O pen the dr aw valve and dr ain the f reezing cy linder t o remove any incorr ectly brix ed product .
26 Model C3 00 NP Op erati ng Pro ced ures Step 2 When all t he product has been drained f rom t he fr eezing cylinder , clos e the dr aw valve and pres s the OF F (< - -) key . Disc ard this produc t. Figur e 37 Repeat Step s 1 an d 2 f or the other f reezing cylinder .
27 Mo del C300 NP Op erati ng Pro cedu res Step 3 To place t he lef t f reezing cy linder in t he SANI TI ZE mode, press t he MENU (S EL) k ey. M ove the c ursor by pres sing the A UTO (- -> ) key unt il the t hird line indi cates RINSE / SANITI ZE.
28 Model C3 00 NP Op erati ng Pro ced ures 080926 Br ush Cleaning Step 1 Prepar e a sink or a pail wit h an approved c leaning solutio n. USE WARM WAT ER AND FOLLOW THE MANUFACTURER 'S SPECIF ICATIO NS (exa mple : Kay-5 R ). IMP ORT ANT: F ollow the label dir ections .
29 Model C3 00 NP Impor tant: Oper ator Che cklis t 080926 Section 7 Important: Operator Checklist Dur ing Cleani ng and Sani tizing ALWAYS FOLLOW LOCAL HEALTH CODES Cleaning and saniti zing schedules are gov erned by your S tat e or local regulat ory agencies and must be followed acc ordingly.
30 Model C3 00 NP Impor tant: Oper ator Che cklis t Winter S torage If t he place of bus iness is to be c losed during t he winter mont hs, it is import ant t o protect t he freezer by following c ert ain precaut ions, par tic ularly if t he building is subjec t t o freez ing conditi ons.
31 Model C3 00 NP Trouble shooting Guide Section 8 T roubleshooting G uide PROBL EM PROBABLE CAUSE REMEDY PAGE REF. 1. Produc t is t oo st iff . a. Too much wat er to s yrup rat io. Im proper brix adjustm ent. a. Adjust the brix accord ing ly. 23 b. Consist ency c ontrol needs adjustm ent.
32 Model C3 00 NP T rouble shooting Guide PROBL EM PROBABLE CAUSE REMEDY PAGE REF. 6. Unable to r emove t he drive s haft fr om t he rear shell bearing. a. Rounded corner s of hex end of dr ive shaf t, driv e coupling, or bot h. a. Replace the dr ive shaf t, or call a servi ce t echn icia n to replace t he direct driv e unit.
33 Mo del C300 NP Parts Rep lacemen t Sch ed ul e Section 9 Parts Replacement Schedule PART DESCRIPTI ON EVERY 4 MONTHS EVERY 8 MONTHS ANNUALLY Scr aper Blade X Drive S haft Seal X Drive Shaf t O- Rin.
Section 10 Parts List 34 Parts List Model C3 00 NP 080207 DESCRI PTI O N PART NUMBER QTY. WARR. CLASS RE MARKS PART S UPDATE ACCUMULATOR-COPPER 2” DIA 13”LG 053377 1 103 ACCUMULAT O R-COPPER 2"DIA 13"L G 053377 1 103 ARM- BAFF LE *345/46/49/355/ 390 047729 2 103 ARM A .
35 Model C3 00 NP Pa rts Li st DESCRI PTI O N PARTS UPDATE REMARKS WARR. CLASS QTY. PART NUMBER CABLE-RIBBON-50C- 3"L-DIL/DIL 040040-055 1 103 J 10UC TO J 9IF CARD-CHECK OUT SLUSHTE CH-5 YR 039976-W5 1 000 CLIP -RET AINE R *355* S YRU P LINE 053197 13 000 SS LINES +O-R ING -3/8 O D X .
36 Parts List Model C3 00 NP 081110 DESCRI PTI O N PARTS UPDATE REMARKS WARR. CLASS QTY. PART NUMBER +LENS-DISPLAY 038221 1 103 +STANDO FF-LENS 038225 4 000 DOOR A.-PAR TIAL-SLUSH-SLFCLO X57324-S ER 2 103 +BUSTE R-ICE 047735 2 103 +CAP A.-SPRING R ETAINER X30591 2 103 +HANDL E A.
37 Model C3 00 NP Pa rts Li st DESCRI PTI O N PARTS UPDATE REMARKS WARR. CLASS QTY. PART NUMBER HARNESS-WIRE-C 300-L0 VO LT 055503 1 103 HOLDER-FUSE-IN LINE-TYPE HLR 045606 1 103 HO OD * C300* 054677 1 103 KIT A.- TUN E UP *C 300* NP X56829 2 000 BEARING-FR ONT 013116 1 000 GASKET-DOO R 5.
38 Parts List Model C3 00 NP DESCRI PTI O N PARTS UPDATE REMARKS WARR. CLASS QTY. PART NUMBER HOSE-BEVERAG E-.375 ID X.635 R 30333 6' 000 REGULAT OR-WATER-3 0 PSI FIXED 064388 1 103 TEE-3/8 BARBX.
39 Model C3 00 NP Pa rts Li st DESCRI PTI O N PARTS UPDATE REMARKS WARR. CLASS QTY. PART NUMBER CHIP-SOFTWARE UVC2 CHIP-SEL X40873 1 103 CHIP-SOFTWARE UVC2 DISPLAY X 40872 1 103 CHIP-SOFTWARE UVC2 U10 ENG LISH X40875 1 103 CHIP-SOFTWARE UVC2 U11 X40876 1 103 IC-PARALLEL PORT CH IP 040176- 006 1 103 PCB A.
40 Parts List Model C3 00 NP DESCRI PTI O N PARTS UPDATE REMARKS WARR. CLASS QTY. PART NUMBER +WASH ER- FREE ZER STU D *348-350 036265 4 000 SHI ELD-S PLAS H *C300* 057939 1 103 S/N K3013295 & U P SHR OU D A.
41 Model C3 00 NP Pa rts Li st DESCRI PTI O N PARTS UPDATE REMARKS WARR. CLASS QTY. PART NUMBER VALVE-EXP-AUTO-1/4S X1/4 FPT 046365 2 103 +BOOT-EXPANSION VALVE 050900 2 000 VALVE -SO LEN OID 208/240 V.
42 Parts List Model C3 00 NP DESCRI PTI O N PARTS UPDATE REMARKS WARR. CLASS QTY. PART NUMBER 50HZ (380-415V 50H Z 3N) COIL-S OLENOID-FL OW CONTROL 062013-40 2 BLOC K-T ERMIN AL 4P L1,L2, L3,N 039424 .
C300NP 056828-27 5/11.
C300NP 056828-33 5/11.
C300NP 056828-58 5/11.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Taylor C300 NP è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Taylor C300 NP - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Taylor C300 NP imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Taylor C300 NP ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Taylor C300 NP, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Taylor C300 NP.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Taylor C300 NP. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Taylor C300 NP insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.