REV. F 5-1-01 1 P/N 99101100 T able of Contents SECTION I. PUMP SAFETY INSTRUCTIONS ------------------------------------------------------- 2 SECTION II. HOW YOUR FIL TER WORKS ----------------------------------------------------------- 2 SECTION III.
P/N 99101100 2 REV. F 5-1-01 SECTION I. PUMP SAFETY INSTRUCTIONS When installing and using this electrical equipment, basic safety precautions should always be followed, including the following: 1 .
REV. F 5-1-01 3 P/N 99101100 SECTION III. CHECK VALVE INSTALLATION INSTRUCTIONS A . INSTALLATION 1 . Turn the pump off, shut off any automatic controls to assure that the system is not inadvertently started during servicing. 2 . Open the High Flow™ manual air relief valve.
P/N 99101100 4 REV. F 5-1-01 6 . Insert the Check Valve into the outlet port approximately 3/4" to 1" deep making sure the rubber diaphragm facing outward (towards you), see Diagram 1. 7 . Reconnect the return hose to the outlet port and tighten the union fitting.
REV. F 5-1-01 5 P/N 99101100 5 . Do not mount electrical controls (on/off switches, timer, etc.) over the filter. You need to be able to stand clear of the filter when starting the pump. 6 . Attach the hair and lint pot to the front of the pump. This is an O-ring seal fitting that requires hand tightening only.
P/N 99101100 6 REV. F 5-1-01 SECTION V. INITIAL START-UP AND RESTART INSTRUCTIONS. 1 . Be sure all connections have been made and are secure. 2 . Make sure the hair and lint pot of the pump is filled with water. (FAILURE TO FILL THE HAIR AND LINT POT WITH WATER WILL RESULT IN DAMAGE TO THE PUMP AND PUMP SEAL).
REV. F 5-1-01 7 P/N 99101100 8 . Remove the CARTRIDGE ELEMENT assembly from the filter body by using the lifting handles and pulling straight up. 9 . Remove the CARTRIDGE ELEMENT from the core assembl.
P/N 99101100 8 REV. F 5-1-01 SECTION VII. WINTERIZING THE FILTER 1 . In areas that have freezing winter temperatures, the pool equipment must be winterized to protect it from damage. 2 . With the pump turned off, open the High Flow™ manual air relief valve.
REV. F 5-1-01 9 P/N 99101100 SECTION IX. TROUBLE SHOOTING Problem Cause Remedy Pool water not 1. Pool chemistry not adequate to inhibit algae growth. Maintain pool chemistry or consult pool service technician . sufficiently clean. 2. Inadequate turnover rate.
P/N 99101100 10 REV. F 5-1-01 3 . SHAFT SEAL - (rotary seal). The shaft seal consists of two parts: a. Rotating ceramic seal, press fitted into the impeller. b. A stationary spring loaded seal, press fitted into the rear of the volute. 4 . THE ELECTRIC MOTOR.
REV. F 5-1-01 11 P/N 99101100 Replacement Parts Find Part Description No. No. 1 98209800 High Flow Manual Air Relief Valve 2 53003201 Pressure Gauge 3 178553 Lid, 50/100 Sq./Ft. 3 178561 Lid, 75 Sq./Ft. 4 59052900 Locking Ring Assy. 5 87300400 Body O-ring 6 59016200 Air Bleed Sock Kit 7 59053500 Center Core, 50 Sq.
P/N 99101100 12 REV. F 5-1-01 SECTION XI. TECHNICAL DATA (continued) B. MAXIM PUMP Find Part Description No. No. 1 98206400 Plug, ¼ in. with O-ring 2 57006500 O-ring 3 39102503 Volute, S Series, vert.
REV. F 5-1-01 13 P/N 99101100 SECTION XI. TECHNICAL DATA, (continued) C. DYNAMO PUMP D Y N A M O C OO SNAP TAB SNAP TAB MOTOR - SEE NOTE 1 SNAP TAB SLOT 18 26 25 24, 24A 20 21 27 19 23 22 12 17 13 14 15 11 10 16 9 9 7 8 6 5 4 3 2 1 * * * Motors 1 35-6471 ¾ A std.
P/N 99101100 14 REV. F 5-1-01 15-5118 2 5 ft. cord and plug 15-5370 2 5 ft. cord and plug, CSA approved 15-5234 3 ft. cord with twist lock plug 35-2245 Strain relief bushing for cords 15-5297 P hoto sensor add-on 2 3 35-4650 B ody - motor enclosure 2 4 35-4656 C a p - motor enclosure 2 5 15-4716 S crew - #10 self-tapping 2 6 15-5371 C ord - 25 ft.
REV. F 5-1-01 15 P/N 99101100.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il System Works 99101100 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del System Works 99101100 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso System Works 99101100 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul System Works 99101100 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il System Works 99101100, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del System Works 99101100.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il System Works 99101100. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo System Works 99101100 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.