Manuale d’uso / di manutenzione del prodotto PH1230 del fabbricante Bard
Vai alla pagina of 23
INST ALLA TION INSTRUCTIONS SINGLE P ACKAGE HEA T PUMPS MODELS PH1224 PH1230 PH1236 Manual : 2100-344 File : V olume II T ab 1 1 Date: 08-21-98 Bard Manufacturing Company Bryan, Ohio 43506 Since 1914.
Contents Getting Other Informations and Publications ........ 1 General Instructions ................................................. 3 Important ................................................................ 3 Shipping Damage .....................
Manual 2100-344 Page 1 Getting Other Information and Publications These publications can help you install the air conditioner or heat pump. You can usually find these at your local library or purchase them directly from the publisher. Be sure to consult current edition of each standard.
Manual 2100-344 Page 2 IMPORTANT: While this electrical data is presented as a guide, it is important to electrically connect properly size fuses and conductor wires in accordance with the National Electrical Code and all existing local codes.
Manual 2100-344 Page 3 TABLE 4 RATED CFM AND EXTERNAL STATIC PRESSURE (ESP) WET COIL (COOLING) l e d o M d e t a R M F C d e t a R P S E d e d n e m m o c e R e g n a R w o l F r i A 4 2 2 1 H P0 0 80 2 .M F C 0 8 8 - 0 8 6 0 3 2 1 H P0 0 0 10 3 .M F C 0 0 1 1 - 5 7 7 6 3 2 1 H P0 0 1 10 2 .
Manual 2100-344 Page 4 MIS-1 177 FIGURE 1 PREFABRICATED ROOF CURB SPECIFICATIONS HEAVY GAUGE GALVANIZED WITH WOOD NAILING STRIP, WELDED/LEAKPROOF ONE PIECE CONSTRUCTION – READY TO INSTALL FIGURE 2 F.
Manual 2100-344 Page 5 INST ALLA TION LOCATION GENERAL The unit must be located outside, or in a well ventilated area. It must not be in the space being heated or cooled.
Manual 2100-344 Page 6 FIGURE 3 ELEVATED MOUNTING PLATFORMS MIS-1 183 MIS-1 185 FIGURE 4 AIRFLOW and SERVICE ACCESS CLEARANCES.
Manual 2100-344 Page 7 FIGURE 5 ROOF TOP APPLICATION (May also be required for ground level installations.) MIS-1 176 FIGURE 6 SLAB MOUNTING AT GROUND LEVEL (Above 32° F Outside Temperature) MIS-1 18.
Manual 2100-344 Page 8 FIGURE 7 CONDENSATE DRAIN TRAP MIS-136 maintained for proper operation. If this is not done, excessive energy use, poor performance, and multiple service problems will result.
Manual 2100-344 Page 9 TABLE 6 – THERMOSTAT WIRE SIZE r e m r o f s n a r T A V A L F e r i W e g u a G h t g n e L m u m i x a M t e e F n I 5 53 . 20 2 8 1 6 1 4 1 2 1 5 4 0 6 0 0 1 0 6 1 0 5 2 WIRING – MAIN POWER Refer to the unit rating plate for wire sizing information and maximum fuse size.
Manual 2100-344 Page 10 TABLE 7 HEAT PUMP THERMOSTATS T A T S O M R E H TE S A B B U SN O I T P I R C S E D 5 4 0 - 3 0 4 8 ) 1 6 7 1 A 1 4 8 T ( f o t r a P t a t s o m r e h T r e v o e g n a h c l .
Manual 2100-344 Page 11 COMPRESSOR CUTOFF THERMOSTAT WIRING (15 KW ONLY) FIGURE 9 UNIT 24V TERMINAL BOARD MIS-1 188 FIGURE 10 UNIT 24V TERMINAL BOARD MIS-1 189 TABLE 8 5 and 10 KW l e d o MW Ks t l o .
Manual 2100-344 Page 12 ST ART UP AND OPERA TION the reversing valve solenoid constantly whenever the system switch on subbase is placed in “Heat” position, the “B” terminal being constantly energized from R. A thermostat demand for heat completes R-Y circuit, pulling in compressor contactor starting compressor and outdoor motor.
Manual 2100-344 Page 13 FIGURE 11 HEAT PUMP CONTROL BOARD MIS-1 191.
Manual 2100-344 Page 14 FAN BLADE SETTINGS Shown in Figure 12 are the correct fan blade setting dimensions for proper air delivery across the outdoor coil.
Manual 2100-344 Page 15 m o t p m y Ss e s u a C e l b i s s o Pk c e h C o t t a h Wr i a p e R r o k c e h C o t w o H r o t c a t n o c r o s s e r p m o C e z i g r e n e t o n s e o d ) g n i l o o c r o g n i t a e h ( g n i r i w t i u c r i c l i t n o Ct i n u t a n o i t c e n n o c R r o f k c e h C .
Manual 2100-344 Page 16 CHECKING TEMPERATURE SENSOR CHECK OUT 1. Disconnect temperature sensor from board and from outdoor coil. 2. Use an ohmmeter and measure the resistance of the sensor. Also use ohmmeter to check for short or open. 3. Check resistance reading to chart of resistance; use sensor ambient temperature.
Manual 2100-344 Page 17 SUCTION AND DISCHARGE TUBE BRAZING Compliant Scroll compressors have copper plated steel suction and discharge tubes. These tubes are far more rugged and less prone to leaks than copper tubes used on other compressors.
Manual 2100-344 Page 18 PRESSURE TABLES TABLE 11 COOLING Air T emperature Entering Outdoor Coil Degrees F l e d o M r i A n r u t e R e r u t a r e p m e Te r u s s e r P5 70 85 80 95 90 0 15 0 10 1 15 1 1 4 2 2 1 H P B D .
Manual 2100-344 Page 19 Wiring Diagram (4098-123) printed from CAD to get size needed.
Manual 2100-344 Page 20 Wiring Diagram (4098-124) printed from CAD to get size needed.
Manual 2100-344 Page 21 Wiring Diagram (4098-21 1) printed from CAD to get size needed.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Bard PH1230 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Bard PH1230 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Bard PH1230 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Bard PH1230 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Bard PH1230, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Bard PH1230.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Bard PH1230. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Bard PH1230 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.