USER’S MANUAL Revision 1.0a X9DRG-HF X9DRG-HTF.
Manual Revision 1.0a Release Date: May 20, 2013 Unless you request and receive written permission from Super Micro Computer , Inc., you may not copy any part of this document.
Preface This manual is written for system integrators, PC technicians and knowledgeable PC users. It provides information for the installation and use of the X9DRG-HF/X9DRG-HTF motherboard.
iv Conventions Used in the Manual Pay special attention to the following symbols for proper system installation and to prevent damage to the system or injury to yourself: W arning: Important informati.
Preface v Contacting Supermicro Headquarters Address: Super Micro Computer , Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. T el: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (T echnical Support) Web Site: www .
vi T able of Contents Preface Chapter 1 Overview 1-1 Overview ......................................................................................................... 1-1 1-2 Processor and Chipset Overview ............................................
vii T able of Contents Power LED .............................................................................................. 2-22 HDD LED/UID Switch ............................................................................... 2-23 NIC1/NIC2 LED Indicators .
viii Chapter 4 BIOS 4-1 Introduction ...................................................................................................... 4-1 4-2 Main Setup ............................................................................................
Chapter 1: Overview 1-1 Chapter 1 Overview 1-1 Overview Checklist Congratulations on purchasing your computer motherboard from an acknowledged leader in the industry . Supermicro boards are designed with the utmost attention to detail to provide you with the highest standards in quality and performance.
1-2 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual Motherboard Image Note : All graphics shown in this manual were based upon the latest PCB Revision available at the time of publishing of the manual. The motherboard you've received may or may not look exactly the same as the graphics shown in this manual.
Chapter 1: Overview 1-3 Motherboard Layout Note: For the latest CPU/Memory updates, please refer to our Website at http://www .supermicro.com/products/motherboard/ for details.
1-4 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual Notes: • See Chapter 3 for detailed information on jumpers, I/O ports and JF1 front panel connections. • " " indicates the location of "Pin 1". • Jumpers/LED Indicators not indicated are for testing only .
Chapter 1: Overview 1-5 X9DRG-HF/X9DRG-HTF Jumpers Jumper Description Default Setting JBT1 Clear CMOS See Chapter 2 JPB1 BMC Enabled Pins 1-2 (Enabled) JPG1 VGA Enabled Pins 1-2 (Enabled) JPL1 GLAN1/G.
1-6 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual LED Description State Status DM1 BMC Heartbeat LED Green BMC Normal LE1 St andby P WR L ED Green: On SB Power On LE4 UID Switch LED Blue Unit Identied Note : CPU1 Slot1, Slot2, Slot5 are available when a processor is installed in CPU Socket 1.
Chapter 1: Overview 1-7 Motherboard Features CPU • Dual Intel ® E5-2600 Series Processors (Socket R- LGA 201 1); each processor supports four full-width Intel QuickPath Interconnect (QPI) links (with support of up to 25.6 GT/s per QPI link and with Data T rans - fer Rate of up to 8.
1-8 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual IPMI 2.0 • IPMI 2.0 supported by the Nuvoton WPCM450R BMC Serial (COM) Port • One (1) Fast UART 16550 Connection: 9-pin RS- 232 port Super.
Chapter 1: Overview 1-9 • Chassis Intrusion Header and Detection Dimensions • 19.80" (L) x 9.20" (W) (502.92 mm x 233.68 mm) Note : For IPMI Conguration Instructions, please refer to the Embedded IPMI Conguration User's Guide available @ http://www .
1-10 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual System Block Diagram Note: This is a general block diagram and may not exactly represent the features on your motherboard. See the Motherboard Features pages for the actual specications of each motherboard.
Chapter 1: Overview 1-1 1 1-2 Processor and Chipset Overview Buil t upo n th e fun ct io nali t y and t he c apa bil it y of Inte l E5 -26 0 0 S er ie s Pro ce ss or s (Soc ket R) and the C602 c hip s.
1-12 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual 1-3 Special Features Recovery from AC Power Loss The Basic I/O System (BIOS) provides a setting that determines how the system will respond when AC power is lost and then restored to the system.
Chapter 1: Overview 1-13 System Resource Alert Thi s feat ure is avai lab le w hen us ed w ith S upe r Do cto r III i n the W in dows O S envir onm ent o r use d wit h Sup er Do c tor II i n Linu x. Su per D oc tor i s use d to not if y the user of c er t ai n syste m event s.
1-14 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual 1-7 Super I/O The Super I/O supports one high-speed, 16550 compatible serial communication header (UART). The UART includes a 16-byte send/receive FIFO, a programmable baud rate generator, complete modem control capability, and a processor interrupt system.
Chapter 1: Overview 1-15 virtualization via Keyboard/Video/Mous e Redirection (KVMR). The WPCM450R Controller is ideal for remote system management. The WPCM450R Controller interfaces with the host system via PCI connections to communicate with the graphics cores.
1-16 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual • OS (Operating System) Independency • Provides remote Hardware Health Monitoring via IPMI.
Chapter 2: Installation 2-1 Chapter 2 Installation 2-1 Standardized W arning Statements The following statements are industry-standard warnings, provided to warn the user of situations which have the potential for bodily injury .
2-2 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual Attention Danger d'explosion si la pile n'est pas remplacée correctement. Ne la remplacer que par une pile de type semblable ou équivalent, recommandée par le fabricant. Jeter les piles usagées conformément aux instructions du fabricant.
Chapter 2: Installation 2-3 Product Disposal W arning! Ultimate disposal of this product should be handled according to all national laws and regulations.
2-4 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual 2-2 Static-Sensitive Devices Electrostatic Discharge (ESD) can damage electronic com ponents. T o avoid dam - aging your system board, it is important to handle it very carefully . The following measures are generally sufcient to protect your equipment from ESD.
Chapter 2: Installation 2-5 OPEN 1st W ARNING! 2-3 Processor and Heatsink Installation W arning : When handling the processor package, avoid placing direct pressure on the label area. Notes: • Always connect the power cord last, and always remove it before adding, removing or changing any hardware components.
2-6 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual Gently push down to pop the load plate open. 2. Press the second load lever labeled 'Close 1st' to release the load plate that covers the CPU socket from its locking position.
Chapter 2: Installation 2-7 1. Using your th umb an d t he in dex ng er, r em ove t he ' WA RN IN G' pl ast ic c ap fro m th e so cket. 2. Use your thumb and index nger to hold the CPU on its edges. Align the CPU keys, which are semi-circle cutouts, against the socket keys.
2-8 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual vertically . Do not rub the CPU against the surface or against any pins of the socket to avoid damaging the CPU or the socket.) 4. With the CPU inside the socket, inspect the four corners of the CPU to make sure that the CPU is properly installed.
Chapter 2: Installation 2-9 Installing a Passive CPU Heatsink 1. Apply the proper amount of thermal grease to the heatsink. 2. Place the heatsink on top of the CPU so that the two mounting holes on the heatsink are aligned with those on the retention mechanism.
2-10 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual Removing the Heatsink W arning: We do not recommend that the CPU or the heatsink be removed. However , if you do need to uninstall the heatsink, please follow the instructions below to uninstall the heatsink to prevent damage done to the CPU or the CPU socket.
Chapter 2: Installation 2-1 1 JPCIE6 JSD1 X9DRG-HF LE4 SW1 JPW10 JLAN2 JLAN1 JRK1 JI2C2 JI2C1 JOH1 JSPK1 JL1 JBT1 J21 JCOM1 JPCIE1 JPCIE2 JPCIE3 JPCIE4 JPCIE5 JPW11 JPW3 JPW4 JPW5 JPW7 JPW8 JVGA1 JPW9.
2-12 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual Memory Support for the X9DRG-HF/X9DRG-HTF Motherboard The X9DRG-HF/X9DRG-HTF Motherboard supports 240-pin Registered (RDIMM)/ Load Reduced (LRDIMM) ECC or Unbuffered (UDIMM) ECC/Non-ECC DDR3 800/1066/1333/1600 MHz memory modules of up to 256 GB in 8 DIMM modules.
Chapter 2: Installation 2-13 Populating UDIMM ECC-Non ECC Memory Modules Intel E5-2600 Series Processor UDIMM Memory Support Ranks Per DIMM & Data Width Memory Capacity Per DIMM (See the Note below) 1 Slot per Channel 1DPC 1.
2-14 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual Populating LRDIMM ECC Memory Modules Intel E5-2600 Series Processor LRDIMM Memory Support Ranks Per DIMM & Data Width Memory Capacity Per DIMM (See the Note Below) 1 Slot Per Channel 1DPC 1.35V 1.
Chapter 2: Installation 2-15 JPCIE6 JSD1 X9DRG-HF LE4 SW1 JPW10 JLAN2 JLAN1 JRK1 JI2C2 JI2C1 JOH1 JSPK1 JL1 JBT1 J21 JCOM1 JPCIE1 JPCIE2 JPCIE3 JPCIE4 JPCIE5 JPW11 JPW3 JPW4 JPW5 JPW7 JPW8 JVGA1 JPW9 .
2-16 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual Installing the Motherboard 1. Install the I/O shield into the chassis. 2. Locate the mounting holes on the motherboard. 3. Locate the matching mounting holes on the chassis. Align the mounting holes on the motherboard against the mounting holes on the chassis.
Chapter 2: Installation 2-17 JPCIE6 JSD1 X9DRG-HF LE4 SW1 JPW10 JLAN2 JLAN1 JRK1 JI2C2 JI2C1 JOH1 JSPK1 JL1 JBT1 J21 JCOM1 JPCIE1 JPCIE2 JPCIE3 JPCIE4 JPCIE5 JPW11 JPW3 JPW4 JPW5 JPW7 JPW8 JVGA1 JPW9 .
2-18 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual JPCIE6 JSD1 X9DRG-HF LE4 SW1 JPW10 JLAN2 JLAN1 JRK1 JI2C2 JI2C1 JOH1 JSPK1 JL1 JBT1 J21 JCOM1 JPCIE1 JPCIE2 JPCIE3 JPCIE4 JPCIE5 JPW11 JPW3 JPW4 JP.
Chapter 2: Installation 2-19 1. GLAN1 (X9DRG-HF), TLAN1 (X9DRG-HTF) 2. GLAN2 (X9DRG-HF), TLAN2 (X9DRG-HTF) 3. IPMI_LAN Ethernet Ports T wo Ethernet ports (LAN1, LAN2) are located on the I/O backplane on the motherboard.
2-20 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual JPCIE6 JSD1 X9DRG-HF LE4 SW1 JPW10 JLAN2 JLAN1 JRK1 JI2C2 JI2C1 JOH1 JSPK1 JL1 JBT1 J21 JCOM1 JPCIE1 JPCIE2 JPCIE3 JPCIE4 JPCIE5 JPW11 JPW3 JPW4 JP.
Chapter 2: Installation 2-21 Pow e r Butto n Blue+ (OH/Fan Fail/ PWR FaiL/UID LED) 1 NIC1 Link LED Rese t Butto n 2 Pow e r Fail LED HDD LED FP PWRLED Reset PWR 3.
2-22 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual Pow e r Butto n Blue+ (OH/Fan Fail/ PWR FaiL/UID LED) 1 NIC1 Link LED Rese t Butto n 2 Pow e r Fail LED HDD LED FP PWRLED Reset PWR 3.3 V ID_UID_SW/3/3V Stby Red+ (Blue LED Cathode) Ground Ground 19 20 3.
Chapter 2: Installation 2-23 Pow e r Butto n Blue+ (OH/Fan Fail/ PWR FaiL/UID LED) 1 NIC1 Link LED Rese t Butto n 2 Pow e r Fail LED HDD LED FP PWRLED Reset PWR 3.
2-24 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual Pow e r Butto n Blue+ (OH/Fan Fail/ PWR FaiL/UID LED) 1 NIC1 Link LED Rese t Butto n 2 Pow e r Fail LED HDD LED FP PWRLED Reset PWR 3.3 V ID_UID_SW/3/3V Stby Red+ (Blue LED Cathode) Ground Ground 19 20 3.
Chapter 2: Installation 2-25 Power Button The Power Button connection is located on pins 1 and 2 of JF1. Momentarily contacting both pins will power on/off the system. This button can also be con - gured to function as a suspend button (with a setting in the BIOS - See Chapter 5).
2-26 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual W arning : T o ensure adequate power supply to your motherboard, be sure to connect all the power connectors mentioned above to your power supply For proper system operation. 2-7 Connecting Cables A.
Chapter 2: Installation 2-27 JPCIE6 JSD1 X9DRG-HF LE4 SW1 JPW10 JLAN2 JLAN1 JRK1 JI2C2 JI2C1 JOH1 JSPK1 JL1 JBT1 J21 JCOM1 JPCIE1 JPCIE2 JPCIE3 JPCIE4 JPCIE5 JPW11 JPW3 JPW4 JPW5 JPW7 JPW8 JVGA1 JPW9 .
2-28 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual JPCIE6 JSD1 X9DRG-HF LE4 SW1 JPW10 JLAN2 JLAN1 JRK1 JI2C2 JI2C1 JOH1 JSPK1 JL1 JBT1 J21 JCOM1 JPCIE1 JPCIE2 JPCIE3 JPCIE4 JPCIE5 JPW11 JPW3 JPW4 JP.
Chapter 2: Installation 2-29 JPCIE6 JSD1 X9DRG-HF LE4 SW1 JPW10 JLAN2 JLAN1 JRK1 JI2C2 JI2C1 JOH1 JSPK1 JL1 JBT1 J21 JCOM1 JPCIE1 JPCIE2 JPCIE3 JPCIE4 JPCIE5 JPW11 JPW3 JPW4 JPW5 JPW7 JPW8 JVGA1 JPW9 .
2-30 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual JPCIE6 JSD1 X9DRG-HF LE4 SW1 JPW10 JLAN2 JLAN1 JRK1 JI2C2 JI2C1 JOH1 JSPK1 JL1 JBT1 J21 JCOM1 JPCIE1 JPCIE2 JPCIE3 JPCIE4 JPCIE5 JPW11 JPW3 JPW4 JP.
Chapter 2: Installation 2-31 JPCIE6 JSD1 X9DRG-HF LE4 SW1 JPW10 JLAN2 JLAN1 JRK1 JI2C2 JI2C1 JOH1 JSPK1 JL1 JBT1 J21 JCOM1 JPCIE1 JPCIE2 JPCIE3 JPCIE4 JPCIE5 JPW11 JPW3 JPW4 JPW5 JPW7 JPW8 JVGA1 JPW9 .
2-32 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual JPCIE6 JSD1 X9DRG-HF LE4 SW1 JPW10 JLAN2 JLAN1 JRK1 JI2C2 JI2C1 JOH1 JSPK1 JL1 JBT1 J21 JCOM1 JPCIE1 JPCIE2 JPCIE3 JPCIE4 JPCIE5 JPW11 JPW3 JPW4 JP.
Chapter 2: Installation 2-33 Management Engine (ME) Recovery Use Jumper JPME1 to select ME Firm - ware Recovery mode, which will limit resource allocation for essential system operation only in order to maintain nor - mal power operation and management.
2-34 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual JPCIE6 JSD1 X9DRG-HF LE4 SW1 JPW10 JLAN2 JLAN1 JRK1 JI2C2 JI2C1 JOH1 JSPK1 JL1 JBT1 J21 JCOM1 JPCIE1 JPCIE2 JPCIE3 JPCIE4 JPCIE5 JPW11 JPW3 JPW4 JP.
Chapter 2: Installation 2-35 JPCIE6 JSD1 X9DRG-HF LE4 SW1 JPW10 JLAN2 JLAN1 JRK1 JI2C2 JI2C1 JOH1 JSPK1 JL1 JBT1 J21 JCOM1 JPCIE1 JPCIE2 JPCIE3 JPCIE4 JPCIE5 JPW11 JPW3 JPW4 JPW5 JPW7 JPW8 JVGA1 JPW9 .
2-36 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual Rear UID LED The r ear U ID L ED is l oc ate d at LE4 o n the backplane. This LED is used in conjunc - tio n wi th th e rea r UI D swi tch to p rovi de easy identication of a system that might be in n ee d of ser vi c e.
Chapter 2: Installation 2-37 Note: For more information on SA T A HostRAID conguration, please refer to the Intel SA T A HostRAID User's Guide posted on our W ebsite @ http:// www .supermicro.com.. Serial A T A PinDenitions Pin# Denition 1 Ground 2 TX_P 3 TX_N 4 Ground 5 RX_N 6 RX_P 7 Ground A.
2-38 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual Notes.
3-1 Chapter 3: Troubleshooting Chapter 3 T roubleshooting 3-1 T roubleshooting Procedures Use the following procedures to troubleshoot your system. If you have followed all of the procedures below and still need assistance, refer to the ‘T echnical Support Procedures’ and/or ‘Returning Merchandise for Service’ section(s) in this chapter .
3-2 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual No Video 1. If the power is on, but you have no video, remove all the add-on cards and cables. 2. Use the speaker to determine if any beep codes exist.
3-3 Chapter 3: Troubleshooting Memory Errors When a No-Memory Beep Code is issued by the system, check the following: 1. Make sure that the memory modules are compatible with the system and that the DIMM modules are properly and fully installed. (For memory compatibility , refer to the Memory Compatibility Chart posted on our Website @ http://www .
3-4 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual 4. System cooling: Check system cooling to make sure that all heatsink fans, and CPU/system fans, etc., work properly . Check Hardware Monitoring set - tings in the BIOS to make sure that the CPU and System temperatures are within the normal range.
3-5 Chapter 3: Troubleshooting 3-2 T echnical Support Procedures Before contacting T echnical Support, please take the following steps. Also, please note that as a motherboard manufacturer , Supermicro also sells motherboards through its channels, so it is best to rst check with your distributor or reseller for troubleshooting services.
3-6 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual Proper Battery Disposal W arning: Please handle used batteries carefully . Do not damage the battery in any way; a damaged battery may release hazardous materials into the environment. Do not discard a used battery in the garbage or a public landll.
3-7 Chapter 3: Troubleshooting 3-4 Frequently Asked Questions Qu es t io n: Wh at a re t he v ar io us t yp es o f me mo r y th at my m ot he r bo ar d c an support? Answer: The motherboard supports Registered (RDIMM)/Load Reduced (LRDIMM) ECC or Unbuffered (UDIMM) ECC/Non-ECC DDR3 memory .
3-8 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual 3-5 Returning Merchandise for Service A receipt or copy of your invoice marked with the date of purchase is required before any warranty service will be rendered. Y ou can obtain service by calling your ven - dor for a Returned Merchandise Authorization (RMA) number .
Chapter 4: AMI BIOS 4-1 Chapter 4 BIOS 4-1 Introduction This chapter describes the AMI BIOS Setup utility for the X9DRG-HF/7TF . It also provides the instructions on how to navigate the AMI BIOS Setup utility screens . The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated.
4-2 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual How T o Change the Conguration Data The conguration data that determines the system parameters may be changed by entering the AMI BIOS Setup utility . This Setup utility can be accessed by pressing <Delete> at the appropriate time during system boot.
Chapter 4: AMI BIOS 4-3 System Date/System Time Use this option to change the system time and date. Highlight System Time or System Date using the arrow keys. Enter new values through the keyboard and press <Enter>. Press the <T ab> key to move between elds.
4-4 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual 4-3 Advanced Setup Congurations Select the Advanced tab to access the following submenu items. Boot Features Quiet Boot This feature allows the user to select bootup screen display between POST mes - sages and the OEM logo.
Chapter 4: AMI BIOS 4-5 Interrupt 19 Capture Interrupt 19 is the software interrupt that handles the boot disk function. When this item is set to Enabled, the ROM BIOS of the host adaptors will "capture" Interrupt 19 at bootup and allow the drives that are attached to these host adaptors to function as bootable disks.
4-6 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual • CPU Stepping • Maximum CPU Speed • Minimum CPU Speed • Processor Cores • Intel HT (Hyper-Threading) T echnology • In.
Chapter 4: AMI BIOS 4-7 Active Processor Cores Set to Enabled to use a processor's second core and above. (Please refer to Intel's website for more information.) The options are All, 1, 2, 4 and 6. Limit CPUID Maximum This feature allows the user to set the maximum CPU ID value.
4-8 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual Intel® Virtualization T echnology (A vailable when supported by the CPU) Sel ec t Enab led t o supp or t Inte l Vi r tu ali zat io n T echn olo gy,.
Chapter 4: AMI BIOS 4-9 CPU C6 Report (A vailable when Power T echnology is set to Custom) Select Enabled to allow the BIOS to report the CPU C6 State (ACPI C3) to the operating system. During the CPU C6 State, the power to all cache is turned off. The options are Enabled and Disabled.
4-10 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual Short Duration Power Limit This item displays the time period during which short duration power is main - tained. The default setting is 0. Chipset Conguration North Bridge This feature allows the user to congure the settings for the Intel North Bridge.
Chapter 4: AMI BIOS 4-1 1 CPU1 Slot 2 PCI-E 3.0 x16 OPROM This feature allows the user to set the PCI-Exp bus speed for the slot specied above. The options are Gen1 (Generation 1), Gen2 and Gen3 . CPU1 Slot 1 PCI-E 3.0 x16 OPROM This feature allows the user to set the PCI-Exp bus speed for the slot specied above.
4-12 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual DIMM Conguration This section displays the following DIMM information. Current Memory Mode This item displays the current memory mode. Current Memory Speed This item displays the current memory speed.
Chapter 4: AMI BIOS 4-13 Channel Interleaving This feature selects from the different channel interleaving methods. The options are Auto , 1 Way , 2 Way , 3, Way , and 4 W ay . Rank Interleaving This feature allows the user to select a rank memory interleaving method.
4-14 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual South Bridge Conguration This feature allows the user to congure the settings for the Intel PCH chip. PCH Information This feature displays the following PCH information. Name : This item displays the name of the PCH chip.
Chapter 4: AMI BIOS 4-15 SA T A Mode Use this feature to congure SA T A mode for a selected SA T A port. The options are Disabled, IDE Mode, AHCI Mode and RAID Mode.
4-16 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual SCU (Storage Control Unit) Conguration Storage Controller Unit Select Enabled to enable PCH SCU storage devices. The options are Disabled and Enabled . OnChip SCU Option ROM Select Enabled to support the onboard SCU Option ROM to boot up the system via a storage device.
Chapter 4: AMI BIOS 4-17 Maximum Read Request Select Auto to allow the system BIOS to automatically set the maximum Read Request size for a PCI-E device to enhance system performance. The options are Auto , 128 Bytes, 256 Bytes, 512 Bytes, 1024 Bytes, 2048 Bytes, and 4096 Bytes.
4-18 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual Super IO Conguration Super IO Chip: This item displays the Super IO chip used in the motherboard. Serial Port 1 Conguration Serial Port Select Enabled to enable a serial port specied by the user .
Chapter 4: AMI BIOS 4-19 Device Mode Use this feature to select the desired mode for a serial port specied. The options are Normal and High Speed. Serial Port Console Redirection COM 1/SOL These two submenus allow the user to congure the following Console Redirection settings for a COM Port specied by the user .
4-20 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual is odd. Select None if you do not want to send a parity bit with your data bits in transmission. Select Mark to add a mark as a parity bit to be sent along with the data bits. Select Space to add a Space as a parity bit to be sent with your data bits.
Chapter 4: AMI BIOS 4-21 Console Redirection Select Enabled to use a COM Port selected by the user for Console Redirection. The options are Enabled and Disabled. Console Redirection Settings This feature allows the user to specify how the host computer will exchange data with the client computer , which is the remote computer used by the user .
4-22 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual ACPI Sleep State Use this feature to select the ACPI State when the system is in sleep mode. Select S1 (CPU_Stop_Clock) to erase all CPU caches and stop executing instructions. Power to the CPU(s) and RAM is maintained, but RAM is refreshed.
Chapter 4: AMI BIOS 4-23 TPM Active Status This item displays the status of TPM Support to indicate if TPM is currently ac - tive or deactivated. TPM Owner Status This item displays the status of TPM Ownership.
4-24 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual iSCSI Conguration: This item displays iSCSI conguration information: iSCSI Initiator Name This item displays the name of the iSCSI Initiator , which is a unique name used in the world. The name must use IQN format.
Chapter 4: AMI BIOS 4-25 • Chip T ype • PCI Device ID • PCI Bus:Device:Function • Link Status • Factory MAC Address • Alternate MAC Address 4-4 Ev ent Logs Select the Event Logs tab to access the following submenu items.
4-26 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual Runtime Error Logging Support Select Enabled to support Runtime Error Logging. The options are Enabled and Disabled. Memory Correctable Error Threshold This feature allows the user to enter the threshold value for correctable memory errors.
Chapter 4: AMI BIOS 4-27 View System Event Log This item allows the user to view the event in the system event log. Select this item and press <Enter> to view the status of an event in the log. Date/T ime/Error Code/Severity 4-5 IPMI Select the IPMI (Intelligent Platform Management Interface) tab to access the fol - lowing submenu items.
4-28 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual Erasing Settings Erase SEL Select Y es, On next reset to erase all system event logs upon next system reboot. Select Y es, On every reset to erase all system event logs upon each system reboot. Select No to keep all system event logs after each system reboot.
Chapter 4: AMI BIOS 4-29 Subnet Mask This item displays the sub-network that this computer belongs to. The value of each three-digit number separated by dots should not exceed 255. Station MAC Address This item displays the Station MAC address for this computer .
4-30 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual Delete Boot Option This feature allows the user to select a EFI boot device to delete from the boot priority list.
Chapter 4: AMI BIOS 4-31 4-8 Save & Exit Thi s s ubm enu all ows th e u ser to c on gur e t he Save and E xit set t ing s f or th e syste m. Discard Changes and Exit Select this option to quit the BIOS Setup without making any permanent changes to the system conguration, and reboot the computer .
4-32 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual Discard Changes Select this feature and press <Enter> to discard all the changes and return to the BIOS setup.
A-1 Appendix A: BIOS POST Error Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-T est) routines, which are performed at each system boot, errors may occur . Non-fatal errors are those which, in most cases, allow the system to continue to boot.
A-2 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual Notes.
Appendix B: Software Installation Instructions B-1 Driver/T ool Installation Display Screen Note 1 : Click the icons showing a hand writing on the paper to view the readme les for each item. Click a computer icon to the right of an item to install an item (from top to the bottom) one at a time.
B-2 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual SuperDoctor ® III Interface Display Screen-I (Health Information) B-2 Conguring SuperDoctor III The SuperDoctor® III program is a Web-based management tool that supports remote management capability .
Appendix B: Software Installation Instructions B-3 SuperDoctor ® III Interface Display Screen-II (Remote Control) Note : The SD III u til it y and t he u ser g uid e ca n be do wnl oad ed f ro m our websit e at: h ttp://ww w.s upermicro.com/products/a cc essories/soft ware/ Sup er Do ct or III .
B-4 X9DRG-HF/X9DRG-HTF Motherboard User ’s Manual Notes.
(Disclaimer Continued) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Supermicro X9DRG-HF è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Supermicro X9DRG-HF - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Supermicro X9DRG-HF imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Supermicro X9DRG-HF ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Supermicro X9DRG-HF, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Supermicro X9DRG-HF.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Supermicro X9DRG-HF. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Supermicro X9DRG-HF insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.