Manuale d’uso / di manutenzione del prodotto X8DTL-3 del fabbricante Supermicro
Vai alla pagina of 101
X8DTL-3 X8DTL-i USER’S MANUAL Revision 1.0a X8DTL-3F X8DTL-iF.
Unless you request and receive written permission from Super Micro Computer , Inc., you may not copy any part of this document. Information in this document is subject to change without notice. Other products and companies referred to herein are trademarks or registered trademarks of their respective companies or mark holders.
Preface About this Manual This manual is written for system integrators, PC technicians and knowledgeable PC users. It provides information for the installation and use of the X8DTL-3/ X8DTL-i/X8DTL-3F/X8DTL-iF motherboard.
W arning: Important information given to ensure proper system installation or to prevent damage to the components. Note: Additional Information given to differentiate various models or to ensure correct system setup.
Contacting Supermicro v Contacting Supermicro Headquarters Address: Super Micro Computer , Inc. 980 Rock A ve. San Jose, CA 95131 U.S.A. T el: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.
X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual vi T able of Contents Preface ........................................................................................................... 3 About this Manual ........................................
T able of Contents vii 2. Front Control Panel ................................................................................... 2-15 3. Front Control Panel Pin De fi nitions .......................................................... 2-16 NMI Button .
X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual viii Onboard Power LED ............................................................................... 2-34 Rear UID LED .............................................................................
Chapter 1: Introduction 1-1 Chapter 1 Introduction 1-1 Overview Checklist Congratulations on purchasing your computer motherboard from an acknowledged leader in the industry . Supermicro boards are designed with the utmost attention to detail to provide the highest standards in quality and performance.
1-2 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF Image Note: The drawings and pictures shown in this manual were based on the latest PCB Revision available at the time of publishing of the manual. The motherboard you’ve received may or may not look exactly the same as the graphics shown in the manual.
Chapter 1: Introduction 1-3 Differences between X8DTL-3/X8DTL-i/X8DTL-3F/ X8DTL-iF X8DTL-3 X8DTL-i X8DTL-3F X8DTL-iF SA T A (ICH10R) Ye s Ye s Ye s Ye s SAS (1068E) Y es No Y es No 3-SGPIO 1/2 Y es No Y es No IPMI 2.0 w/KVM No No Y es Y es Notes SAS Ports, SAS jumpers, and the LSI 1068E chip are available on the 1.
1-4 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual Jumpers not indicated are for test purposes only. • " " indicates the location of Pin 1. • When LE1 is on, the onboard power connection is on. Make sure to unplug the • power cables before removing or installing components.
Chapter 1: Introduction 1-5 X8DTL-3/X8DTL-3F/ X8DTL-i/ X8DTL-iF Quick Reference Jumper Description Default Setting JBT1 CMOS Clear Open (Normal) JI 2 C1/JI 2 C2 SMB to PCI/PCI-E Slots Open/Open (Disab.
1-6 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual Motherboard Features CPU T wo Intel • ® 5500 Series (LGA 1366) processors, each processor supporting two full-width Intel QuickPath Interconnect (QPI) @6.4 GT/s with a total of up to 51.2 GB/s Data T ransfer Rate (6.
Chapter 1: Introduction 1-7 ACPI Features Slow blinking LED for suspend state indicator • Mai n s wit ch o ve rride m echa nism • AC PI Po wer Ma na g em en t • K e y b o a r d W a k e u p f r o.
1-8 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual Block Diagram of the 5500 Chipset Note: This is a general block diagram. Please see the previous Mother- board Features pages for details on the features of each motherboard.
Chapter 1: Introduction 1-9 1-3 Chipset Overview Bui lt up on th e fu nct io nali t y and t he c apa bil it y of th e 55 0 0 pl at fo rm, t he X8 DTL - 3/ X8 DTL - i / X8 DTL - 3F/ X8 DTL - i F mot he.
1-10 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual 1-4 Special Features Recovery from AC Power Loss BIOS provides a setting for you to determine how the system will respond when AC power is lost and then restored to the system.
Chapter 1: Introduction 1-1 1 not if y t he u ser o f ce r t ain sy stem even ts. Fo r examp le, you c an a ls o co n fi gure S up e ro Do ct o r to pr o v id e y ou wi t h w ar ni n g s w h en th e s y st em t e mp e ra t u r e , CP U temp er ature s, vol tag es an d fan s pee ds go b eyond a p re - d e fi ned range.
1-12 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual WOL capability . In addition, an onboard LAN controller can also support WOL without any connection to the WOL header . The 3-pin WOL header is to be used with a LAN add-on card only . Note : W ake-On-LAN requires an A TX 2.
Chapter 1: Introduction 1-13 ment through an SMI or SCI function pin. It also features auto power management to reduce power consumption. 1-9 Overview of the W inbond WPCM450 Controller (For X8DTL-3F/.
1-14 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual Notes.
Chapter 2: Installation 2-1 Chapter 2 Installation 2-1 Static-Sensitive Devices Electrostatic Discharge (ESD) can damage electronic com ponents. T o prevent dam- age to your system board, it is important to handle it very carefully . The following measures are generally suf fi cient to protect your equipment from ESD.
2-2 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual Locate the matching mounting holes on the chassis. Align the mounting holes 3. on the motherboard against the mounting holes on the chassis. Install standoffs in the chassis as needed. 4. Install the motherboard into the chassis carefully to avoid damage to mother- 5.
Chapter 2: Installation 2-3 2-3 Processor and Heatsink Installation When handling the processor package, avoid placing direct pressure on the label area of the fan. Notes: Always connect the power cord last and always remove it before adding, re- 1. moving or changing any hardware components.
2-4 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual Socket Keys After removing the plastic cap, 1. using your thumb and the index fi nger , hold the CPU at the north and south center edges. Align the CPU key , the semi- 2. circle cutout, against the socket key , the notch below the gold color dot on the side of the socket.
Chapter 2: Installation 2-5 Installing a CPU Heatsink Screw#1 Screw#2 Do not apply any thermal 1. grease to the heatsink or the CPU die because the required amount has already been ap- plied. Screw#1 Screw#2 Install Screw#1 Place the heatsink on top of the 2.
2-6 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual Removing the Heatsink War ni ng: We do n ot re co mme nd t hat th e CPU o r the h eats ink b e re - m o v e d .
Chapter 2: Installation 2-7 X8DTL Series 2-4 Installing and Removing the Memory Modules Note : Chec k the S upe r mic ro we b site fo r re co mme nde d me mor y mo dul es. CAUTI O N E x e r ci s e e x t r e m e ca r e w h e n i n s t a l l i n g o r r e m o v i n g D I M M mo dul es to p revent a ny pos si ble d ama ge.
2-8 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual Memory Support The X8DTL-3/-i/-3F/iF supports up to 24 GB Registered ECC DDR3 1333 MHz/1066 MHz/800 MHz in six DIMMs.
Chapter 2: Installation 2-9 Possible System Memory Allocation & A vailability System Device Size Physical Memory Remaining (-Available) (4 GB T otal System Memory) Firmware Hub fl ash memory (System BIOS) 1 MB 3.99 GB Local APIC 4 KB 3.99 GB Area Reserved for the chipset 2 MB 3.
2-10 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual JPW3 JPW2 JBT1 JPI2C COM1 I-SATA0 I-Button JPS1 JWD JPL2 JPL1 JF1 SP1 1 JWOL LE1 D20 JBAT1 JP3 JL1 JPS2 JOH1 JPB JP5 J16 JD1 CPU2 FAN Slot3 PCI-E 1.0 x4 7HG 5ADG 7TN100C W8379 W8352 Slot6 PCI-E 2.
Chapter 2: Installation 2-1 1 A TX PS/2 Keyboard and PS/2 Mouse Ports The A TX PS/2 keyboard and PS/2 mouse are located next to the Back Panel USB Ports 0~1 on the moth- erboard.
2-12 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual 1. Backpanel USB 0 2. Backpanel USB 1 3. Front Panel USB 2/3 4. Front Panel USB 4/5 5. Front Panel USB 6 Universal Serial Bus (USB) T wo Universal Serial Bus ports (USB 0 and USB 1) are located on the I/O back panel.
Chapter 2: Installation 2-13 Serial Ports T wo COM connections (COM1 & COM2) are located on the motherboard. COM1 is located on the Backplane IO panel. COM2 is located next to the onboard buzzer to provide additional serial connection support. See the table on the right for pin de fi nitions.
2-14 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual 1. LAN1 2. LAN2 3. LAN5 (X8DTL-3F/iF only) Ethernet Ports T wo Ethernet ports (LAN 1/LAN2) are located at on the IO backplane. In addition, a dedicated LAN is also lo- cated on the X8DTL-3F/-iF to provide KVM support for IPMI 2.
Chapter 2: Installation 2-15 2. Front Control Panel JF1 contains header pins for various buttons and indicators that are normally lo- cated on a control panel at the front of the chassis. These connectors are designed speci fi cally for use with Supermicro server chassis.
2-16 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual Po we r Butto n OH/Fan Fail LED 1 NIC1 L ED Re set Bu tto n 2 Po wer Fa il LED HDD LED Po we r LED Rese t PWR Vcc Vcc Vcc Vcc/Front UID LED Gr ound Gr ound 19 20 Vcc X Gr ound NMI X Vcc NIC2 LED Power LED Th e Power LED c o nne ct io n is lo c ated o n p i n s 15 a n d 1 6 o f J F1.
Chapter 2: Installation 2-17 Po we r Butto n OH/Fan Fail LED 1 NIC1 L ED Rese t Button 2 Po wer Fa il LED HDD LED Po we r LED Rese t PWR Vcc Vcc Vcc Vcc/Front UID LED Gr ound Gr ound 19 20 Vcc X Gr ou.
2-18 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual Po we r Butto n OH/Fan Fail LED 1 NIC1 L ED Rese t Button 2 Po wer Fa il LED HDD LED Po we r LED Rese t PWR Vcc Vcc Vcc Vcc/Front UID LED Gr ound Gr ound 19 20 Vcc X Gr ound NMI X Vcc NIC2 LED Power Fail LED Th e Power Fail LE D co nne ct io n is lo ca ted on p ins 5 an d 6 of JF1 .
Chapter 2: Installation 2-19 Po we r Butto n OH/Fan Fail LED 1 NIC1 L ED Rese t Button 2 Po wer Fa il LED HDD LED Po we r LED Rese t PWR Vcc Vcc Vcc Vcc/Front UID LED Gr ound Gr ound 19 20 Vcc X Gr ound NMI X Vcc NIC2 LED Power Button The Power Button connection is located on pins 1 and 2 of JF1.
2-20 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual JPW3 JPW2 JBT1 JPI2C COM1 I-SAT A0 I-Button JPS1 JWD JPL2 JPL1 JF1 SP1 1 JWOL LE1 D20 JBAT1 JP3 JL1 JPS2 JOH1 JPB JP5 J16 JD1 CPU2 FAN Slot3 PCI-E 1.0 x4 7HG 5ADG 7TN100C W8379 W8352 Slot6 PCI-E 2.
Chapter 2: Installation 2-21 JPW3 JPW2 JBT1 JPI2C COM1 I-SAT A0 I-Button JPS1 JWD JPL2 JPL1 JF1 SP1 1 JWOL LE1 D20 JBAT1 JP3 JL1 JPS2 JOH1 JPB JP5 J16 JD1 CPU2 FAN Slot3 PCI-E 1.0 x4 7HG 5ADG 7TN100C W8379 W8352 Slot6 PCI-E 2.0 x8 (in x16 Slot) JI2C2 SAS6 SAS5 SAS4 SAS3 SAS2 SAS1 Slot4 PCI-E 2.
2-22 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual JPW3 JPW2 JBT1 JPI2C COM1 I-SAT A0 I-Button JPS1 JWD JPL2 JPL1 JF1 SP1 1 JWOL LE1 D20 JBAT1 JP3 JL1 JPS2 JOH1 JPB JP5 J16 JD1 CPU2 FAN Slot3 PCI-E 1.0 x4 7HG 5ADG 7TN100C W8379 W8352 Slot6 PCI-E 2.
Chapter 2: Installation 2-23 JPW3 JPW2 JBT1 JPI2C COM1 I-SAT A0 I-Button JPS1 JWD JPL2 JPL1 JF1 SP1 1 JWOL LE1 D20 JBAT1 JP3 JL1 JPS2 JOH1 JPB JP5 J16 JD1 CPU2 FAN Slot3 PCI-E 1.0 x4 7HG 5ADG 7TN100C W8379 W8352 Slot6 PCI-E 2.0 x8 (in x16 Slot) JI2C2 SAS6 SAS5 SAS4 SAS3 SAS2 SAS1 Slot4 PCI-E 2.
2-24 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual JPW3 JPW2 JBT1 JPI2C COM1 I-SAT A0 I-Button JPS1 JWD JPL2 JPL1 JF1 SP1 1 JWOL LE1 D20 JBAT1 JP3 JL1 JPS2 JOH1 JPB JP5 J16 JD1 CPU2 FAN Slot3 PCI-E 1.0 x4 7HG 5ADG 7TN100C W8379 W8352 Slot6 PCI-E 2.
Chapter 2: Installation 2-25 JPW3 JPW2 JBT1 JPI2C COM1 I-SAT A0 I-Button JPS1 JWD JPL2 JPL1 JF1 SP1 1 JWOL LE1 D20 JBAT1 JP3 JL1 JPS2 JOH1 JPB JP5 J16 JD1 CPU2 FAN Slot3 PCI-E 1.0 x4 7HG 5ADG 7TN100C W8379 W8352 Slot6 PCI-E 2.0 x8 (in x16 Slot) JI2C2 SAS6 SAS5 SAS4 SAS3 SAS2 SAS1 Slot4 PCI-E 2.
2-26 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual JPW3 JPW2 JBT1 JPI2C COM1 I-SAT A0 I-Button JPS1 JWD JPL2 JPL1 JF1 SP1 1 JWOL LE1 D20 JBAT1 JP3 JL1 JPS2 JOH1 JPB JP5 J16 JD1 CPU2 FAN Slot3 PCI-E 1.0 x4 7HG 5ADG 7TN100C W8379 W8352 Slot6 PCI-E 2.
Chapter 2: Installation 2-27 JPW3 JPW2 JBT1 JPI2C COM1 I-SAT A0 I-Button JPS1 JWD JPL2 JPL1 JF1 SP1 1 JWOL LE1 D20 JBAT1 JP3 JL1 JPS2 JOH1 JPB JP5 J16 JD1 CPU2 FAN Slot3 PCI-E 1.0 x4 7HG 5ADG 7TN100C W8379 W8352 Slot6 PCI-E 2.0 x8 (in x16 Slot) JI2C2 SAS6 SAS5 SAS4 SAS3 SAS2 SAS1 Slot4 PCI-E 2.
2-28 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual JPW3 JPW2 JBT1 JPI2C COM1 I-SAT A0 I-Button JPS1 JWD JPL2 JPL1 JF1 SP1 1 JWOL LE1 D20 JBAT1 JP3 JL1 JPS2 JOH1 JPB JP5 J16 JD1 CPU2 FAN Slot3 PCI-E 1.0 x4 7HG 5ADG 7TN100C W8379 W8352 Slot6 PCI-E 2.
Chapter 2: Installation 2-29 JPW3 JPW2 JBT1 JPI2C COM1 I-SAT A0 I-Button JPS1 JWD JPL2 JPL1 JF1 SP1 1 JWOL LE1 D20 JBAT1 JP3 JL1 JPS2 JOH1 JPB JP5 J16 JD1 CPU2 FAN Slot3 PCI-E 1.0 x4 7HG 5ADG 7TN100C W8379 W8352 Slot6 PCI-E 2.0 x8 (in x16 Slot) JI2C2 SAS6 SAS5 SAS4 SAS3 SAS2 SAS1 Slot4 PCI-E 2.
2-30 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual JPW3 JPW2 JBT1 JPI2C COM1 I-SAT A0 I-Button JPS1 JWD JPL2 JPL1 JF1 SP1 1 JWOL LE1 D20 JBAT1 JP3 JL1 JPS2 JOH1 JPB JP5 J16 JD1 CPU2 FAN Slot3 PCI-E 1.0 x4 7HG 5ADG 7TN100C W8379 W8352 Slot6 PCI-E 2.
Chapter 2: Installation 2-31 JPW3 JPW2 JBT1 JPI2C COM1 I-SAT A0 I-Button JPS1 JWD JPL2 JPL1 JF1 SP1 1 JWOL LE1 D20 JBAT1 JP3 JL1 JPS2 JOH1 JPB JP5 J16 JD1 CPU2 FAN Slot3 PCI-E 1.0 x4 7HG 5ADG 7TN100C W8379 W8352 Slot6 PCI-E 2.0 x8 (in x16 Slot) JI2C2 SAS6 SAS5 SAS4 SAS3 SAS2 SAS1 Slot4 PCI-E 2.
2-32 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual JPW3 JPW2 JBT1 JPI2C COM1 I-SAT A0 I-Button JPS1 JWD JPL2 JPL1 JF1 SP1 1 JWOL LE1 D20 JBAT1 JP3 JL1 JPS2 JOH1 JPB JP5 J16 JD1 CPU2 FAN Slot3 PCI-E 1.0 x4 7HG 5ADG 7TN100C W8379 W8352 Slot6 PCI-E 2.
Chapter 2: Installation 2-33 JPW3 JPW2 JBT1 JPI2C COM1 I-SAT A0 I-Button JPS1 JWD JPL2 JPL1 JF1 SP1 1 JWOL LE1 D20 JBAT1 JP3 JL1 JPS2 JOH1 JPB JP5 J16 JD1 CPU2 FAN Slot3 PCI-E 1.0 x4 7HG 5ADG 7TN100C W8379 W8352 Slot6 PCI-E 2.0 x8 (in x16 Slot) JI2C2 SAS6 SAS5 SAS4 SAS3 SAS2 SAS1 Slot4 PCI-E 2.
2-34 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual JPW3 JPW2 JBT1 JPI2C COM1 I-SAT A0 I-Button JPS1 JWD JPL2 JPL1 JF1 SP1 1 JWOL LE1 D20 JBAT1 JP3 JL1 JPS2 JOH1 JPB JP5 J16 JD1 CPU2 FAN Slot3 PCI-E 1.0 x4 7HG 5ADG 7TN100C W8379 W8352 Slot6 PCI-E 2.
Chapter 2: Installation 2-35 JPW3 JPW2 JBT1 JPI2C COM1 I-SAT A0 I-Button JPS1 JWD JPL2 JPL1 JF1 SP1 1 JWOL LE1 D20 JBAT1 JP3 JL1 JPS2 JOH1 JPB JP5 J16 JD1 CPU2 FAN Slot3 PCI-E 1.0 x4 7HG 5ADG 7TN100C W8379 W8352 Slot6 PCI-E 2.0 x8 (in x16 Slot) JI2C2 SAS6 SAS5 SAS4 SAS3 SAS2 SAS1 Slot4 PCI-E 2.
2-36 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual Notes.
3-1 Chapter 3: T roubleshooting Chapter 3 T roubleshooting 3-1 T roubleshooting Procedures Use the following procedures to troubleshoot your system. If you have followed all of the procedures below and still need assistance, refer to the ‘T echnical Support Procedures’ and/or ‘Returning Merchandise for Service’ section(s) in this chapter .
3-2 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual No Video If the power is on but you have no video, remove all the add-on cards and 1. cables. Use the speaker to determine if any beep codes exist. Refer to the Appendix 2. for details on beep codes.
3-3 Chapter 3: T roubleshooting 3-2 T echnical Support Procedures Before contacting T echnical Support, please take the following steps. Also, please note that as a motherboard manufacturer , Supermicro does not sell directly to end- users, so it is best to fi rst check with your distributor or reseller for troubleshooting services.
3-4 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual Qu e st io n: How d o I u pd at e my B IO S? Answer: It is recommended that you do not upgrade your BIOS if you are not experiencing any problems with your system. Updated BIOS fi les are located on our web site at http://www .
Chapter 4: AMI BIOS 4-1 Chapter 4 BIOS 4-1 Introduction This chapter describes the AMI BIOS Setup Utility for the X8DTL Series moth- erboard. The AMI ROM BIOS is stored in a Flash EEPROM and can be easily updated. This chapter describes the basic navigation of the AMI BIOS Setup Utility setup screens.
4-2 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual Starting the Setup Utility Normally , the only visible Power-On Self-T est (POST) routine is the memory test. As the memory is being tested, press the <Delete> key to enter the main menu of the AMI BIOS Setup Utility .
Chapter 4: AMI BIOS 4-3 Supermicro X8DTL-3/i/3F/iF V ersion • : This item displays the BIOS revision used in your system. Build Date • : This item displays the date when this BIOS was completed.
4-4 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual 4-3 Advanced Setup Con fi gurations Use the arrow keys to select Boot Setup and hit <Enter> to access the submenu items: BOOT Features Quick Boot If Enabled, this option will skip certain tests during POST to reduce the time needed for system boot.
Chapter 4: AMI BIOS 4-5 W ait For 'F1' If Error Th is fo rc es t he sys tem to wa it unt il th e ' F 1' key is pre ss ed if a n er ro r oc c urs .
4-6 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual RTD Alarm Time (A vailable if Resume on RTC Alarm is Enabled) Set the time when the system wakes up during the day speci fi ed under R TC Alarm Date above. Processor and Clock Options This submenu allows the user to con fi gure the Processor and Clock settings.
Chapter 4: AMI BIOS 4-7 Execute-Disable Bit Capability (A vailable when supported by the OS and the CPU) Set to Enabled to enable the Execute Disable Bit which will allow the processor to designate ar.
4-8 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual C1 Auto Demotion When this feature is enabled, the CPU will conditionally demote C3, C6 or C7 re- quests to C1 based on un-core auto-demote information.
Chapter 4: AMI BIOS 4-9 QPI L0s and L1 This enables the QPI power state to low power. L0s and L1 are automatically se- lected by the motherboard. The options are Enabled and Disabled. Memory Frequency This feature forces a DDR3 memory module to run at a speci fi c frequency .
4-10 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual Guardband T emperature (Closed Loop only) This is the temperature which applies to the DIMM temperature threshold. Each step is in 0.5 o C increment. The default is [006] . Inlet T emperature This is the temperature detected at the chassis inlet.
Chapter 4: AMI BIOS 4-1 1 NUMA Support Select Enabled to use the feature of Non-Uniform Memory Access to improve CPU performance. The options are Enabled and Disabled . Intel I/OA T The Intel I/OA T (I/O Acceleration T echnology) signi fi cantly reduces CPU overhead by leveraging CPU architectural improvements, freeing resources for other tasks.
4-12 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual Code Base will appear . When the option-AHCI is selected, the item-SA T A AHCI will be available.) ICH RAID Code Base (This feature is available when the option-RAID is selected) Select Intel to enable Intel's SA T A RAID fi rmware to con fi gure Intel's SA T A RAID settings.
Chapter 4: AMI BIOS 4-13 Block (Multi-Sector T ransfer) Block Mode boosts the IDE drive performance by increasing the amount of data transferred. Only 512 bytes of data can be transferred per interrupt if Block Mode is not used. Block Mode allows transfers of up to 64 KB per interrupt.
4-14 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual Select MWDMA2 to allow the BIOS to use Multi-Word DMA mode 2. It has a data transfer rate of 16.6 MBs. Select UDMA0 to allow the BIOS to use Ultra DMA mode 0. It has a data transfer rate of 16.
Chapter 4: AMI BIOS 4-15 PCI Latency Timer This feature sets the latency T imer of each PCI device installed on a PCI bus. Select 64 to set the PCI latency to 64 PCI clock cycles. The options are 32, 64 , 96, 128, 160, 192, 224 and 248. PCI IDE BusMaster When enabled, the BIOS uses PCI bus mastering for reading/writing to IDE drives.
4-16 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual Remote Access Con fi guration Remote Access This allows the user to enable the Remote Access feature.
Chapter 4: AMI BIOS 4-17 Hardware Health Monitor This feature allows the user to monitor system health and review the status of each item as displayed. CPU Overheat Alarm This option allows the user to select the CPU Overheat Alarm setting which de- termines when the CPU OH alarm will be activated to provide warning of possible CPU overheat.
4-18 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual is still within its normal operating state and below the CPU ‘T emperature T olerance’. The motherboard fans and CPU will run normally as con fi gured in the BIOS. The fans may adjust to a faster speed depending on the Fan Speed Control settings.
Chapter 4: AMI BIOS 4-19 CPU on-die temperature increases, the fan speed will also increase, and vice versa. Select Workstation if your system is used as a W orkstation. Select Server if your system is used as a Server . Select Disabled to disable the fan speed control func- tion and allow the onboard fans to constantly run at full speed.
4-20 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual Headless Mode This feature is used to enable system to function without a keyboard, monitor and/ or mouse attached The options are Enabled and Disabled . ACPI V ersion Features The options are ACPI v1.
Chapter 4: AMI BIOS 4-21 Event Sensor Number • Event Dir T ype • Event Data. • Clear BMC System Event Log Select OK and press the <Enter> key to clear the BMC system log. Select Cancel to keep the BMC System log. The options are OK and Cancel.
4-22 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual Gateway Address This is the IP address of the gateway in the network. This is usually a router . Mac Address The BIOS will automatically enter the Mac address of this machine; however it may be over-ridden.
Chapter 4: AMI BIOS 4-23 or reset after an operating system failure is detected. The options are [5 Min] , [1 Min], [30 Sec], and [10 Sec]. Event Log Con fi guration View Event Log Use this option to view the System Event Log. Mark all events as read This option marks all events as read.
4-24 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual Supervisor Password This item indicates if a Supervisor password has been entered for the system. "Not Installed" means a Supervisor password has not been used. User Password This item indicates if a user password has been entered for the system.
Chapter 4: AMI BIOS 4-25 4-5 Boot Con fi guration Use this feature to con fi gure boot settings. Boot Device Priority This feature allows the user to specify the sequence of priority for the Boot Device. The settings are 1st boot device, 2nd boot device, 3rd boot device, 4th boot device, 5th boot device and Disabled.
4-26 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual Save Changes and Exit After con fi guration the Setup settings, select this option to save the changes and exit the BIOS Setup Utility . The system will then reboot, and new system parameters will become effective.
Chapter 4: AMI BIOS 4-27 4-7 BIOS Recovery W arning! Do not upgrade the BIOS unless your system has a BIOS-related issue. Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update.
4-28 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual 4.7.2 Boot Sector Recovery from an IDE CD-ROM This process is almost identical to the process of Boot Sector Recovery from a USB device, except that the BIOS image fi le is loaded from a CD-ROM.
Chapter 4: AMI BIOS 4-29 5. Following the instructions given on the screen to update the BIOS. These instructions are also shown below . a. At the prompt, press the <SpaceBar> to update the BIOS. b. When asked to con fi rm BIOS updating, press <y> to con fi rm BIOS updates.
4-30 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual 8. Once remote BIOS fl ash is completed, the system will reboot. Note: AMIBIOS Serial Flash will work with any terminal communications program that supports VT -100 and XModem protocols, including protocols designed for GNU/LINUX & BSD operating systems such as minicom.
A-1 Appendix A: BIOS POST Error Codes Appendix A BIOS Error Beep Codes During the POST (Power-On Self-T est) routines, which are performed each time the system is powered on, errors may occur . Non-fatal errors are those which, in most cases, allow the system to continue the boot-up process.
A-2 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual Notes.
Appendix B: Installing the Windows OS B-1 Appendix B Installing the Windows OS After all hardware components have been installed, you must fi rst con fi gure Intel South Bridge RAID Settings before you install the Windows OS and other software drivers.
B-2 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual B-2 Installing the Windows OS to a Non-RAID System Insert Microsoft's Windows XP/Windows 2003/Windows 2008/Windows Vista 1. Setup CD in the CD Driver , and the system will start booting up from CD.
Appendix C: Software Installation Instructions C-1 Driver/T ool Installation Display Screen Notes : 1. Click the icons showing a hand writing on the paper to view the readme fi les for each item. Click on a computer icon to the right of an item to install an item (from top to the bottom) one at a time.
C-2 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual Supero Doctor III Interface Display Screen-I (Health Information) C-2 Con fi guring Supero Doctor III The Supero Doctor III program is a Web-base management tool that supports remote management capability .
Appendix C: Software Installation Instructions C-3 Supero Doctor III Interface Display Screen-II (Remote Control) Note : SD III S of t wa re Revi sio n 1 .0 c a n be dow nl oad ed f rom o ur Web site at : f tp:// f tp. supe r mic ro.c om /ut ilit y/ Supe ro _ D oc to r_I II/ .
C-4 X8DTL-3/X8DTL-i/X8DTL-3F/X8DTL-iF User's Manual Notes.
(Disclaimer Continued) The products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or systems, aircraft, aircraft devices, .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Supermicro X8DTL-3 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Supermicro X8DTL-3 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Supermicro X8DTL-3 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Supermicro X8DTL-3 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Supermicro X8DTL-3, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Supermicro X8DTL-3.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Supermicro X8DTL-3. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Supermicro X8DTL-3 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.