SC743 Chassis Series SC743TQ-865 SC743TQ-R760 SC743S2-760 SC743S1-760 SC743T -R760 SC743i-R760 SC743TQ-650 SC743S2-650 SC743S1-650 SC743T -650 SC743i-650 SC743S1-645 SC743T -645 SC743i-645 SC743i-465 SC743TQ-865B-SQ USER’S MANUAL 1.
ii SC743 Chassis Manual Manual Revision 1.2a Release Date: December 15, 2008 Unless you r equest and receive written perm ission from Super Mi cro Computer , Inc., you may not copy any part of this document. Information in thi s document is subject to change with out notice.
iii Preface Preface About This Manual This ma nual is writ ten for pro fessional syst em i ntegrators and PC tech nicians. It provides i nformation for the insta llation and use of the SC743 cha ssis. Installatio n and mainten ance should be per formed by experienc ed technicians onl y .
iv Manual Organization Chapter 1: Introduction The r st chapter provides a checkl ist of t he main c omponents inc luded with this chassis and des cribes the main featur es of the SC743 chassis. This chapt er also includes contact information. Chapter 2: System Safety This chapter lists warnings, precautions, and system safety .
v Preface T able of Contents Chapter 1 Introductio n 1-1 Overview ......................................................................................................... 1- 1 1-2 Shipping List ........................................................
vi 4-9 Installing the Motherboard ............................................................................. 4-1 1 4-10 Installing Add-on Cards ................................................................................. 4-1 3 4 -1 1 Power Supply .
Chapter 1 Introduction 1-1 Overview Supermicro’s SC743 chassis features a unique and highly-optimized design. The chassis is equipped with a high-efciency 80%+ low-noise power supply .
SC743 Chassis Manual 1-2 1-3 Where to get Replacement Components Althou gh no t freq uently , you ma y need repl acement parts for yo ur sy stem. T o ensure the highest level of professional service and technical support, we strongly recommend purcha sing exclusi vely from our Supermicr o Authorized Di stributors / System Integrators / Resellers .
1-3 Chapter 1: Introduction 1-4 Contacting Supermicro Headquarters Address: Super Micro Computer , Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. T el: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.
SC743 Chassis Manual 1-4 1-5 Returning Merchandise for Service A receipt or copy of your invoice marked with the date of purchase is required be - fore a ny warranty servic e will be ren dered. Y ou can obtain service by c alling your vendor for a Returned Merchandise Authorization (RMA) number .
2-1 Chapter 2: System Safety Chapter 2 System Safety 2-1 Overview This chapter provi des a quick setup chec klist to get your cha ssis up and runnin g. Following the steps in the order given should enable you to have your chassis setup and operational within a minimal amount of time.
SC743 Chassis Manual 2-2 2-4 Electrical Safety Precautions Basic electr ical safety precaut ions should be follow ed to protect yourse lf from harm and the SC743 from damage: Be aware of the lo cation.
2-3 Chapter 2: System Safety DVD-ROM laser: CAUTION - This server may have come equipped with a • DVD-ROM d rive. T o prev ent direct exp osure to the laser b eam and hazar dous radiation exposure, do not open the enclosure or use the unit in any uncon - ventional way .
SC743 Chassis Manual 2-4 T ouch a grounded metal obje ct b efore removing any boa rd f rom its ant istatic • bag. Do not let components or PCBs come into contact with your clothing, which may • retain a charge even if you are wearing a wrist strap.
3-1 Chapter 3: Chassis Components Chapter 3 Chassis Components 3-1 Overview This chapter describes the most common components included with your chassis. Some components listed may not be included or compatible with your particular chassis model. For more i nformation, see the inst allation instructions detailed later in this manual.
SC743 Chassis Manual 3-2 3-3 Where to get Replacement Components Althou gh no t freq uently , you ma y need repl acement parts for yo ur sy stem. T o ensure the highest level of professional service and technical support, we strongly recommend purchasing exclusively from our Supermicro Authorized Distributors/ System Integra tors/Resellers.
3-3 Chapter 3: Chassis Components 3-5 Control Panel Buttons There are two push-buttons located on the front of the chassis. These are (in order from left to right) a reset button and a power on/off button. Power: • The main power swi tch is used to apply or remove power fr om the power supply to the s erver system.
SC743 Chassis Manual 3-4 HDD: • Indicates IDE channel activity . SAS/SA T A drive, SCSI drive, and/or DVD- ROM drive activity when ashing. NIC2: • Indicates network activity on GLAN2 when ashing. NIC1: • Indicates network activity on GLAN1 when ashing.
3-5 Chapter 3: Chassis Components Power Fail: • Indicates a power failure to the system's power supply units. !.
SC743 Chassis Manual 3-6 Notes.
4-1 Chapter 4: Chassis Setup and Maintenance Chapter 4 Chassis Setup and Maintenance 4-1 Overview This chapter covers the steps required to install components and perform mainte - nance on the chassis. The only tool you will need to install components and perform maintenance is a Phillips screwdriver.
SC743 Chassis Manual 4-2 4-2 Removing the Chassis Cover Disconnecting the Chassis from the Power Source T urn off all peri pheral devices and turn off the pow er supply connected to the 1. SC743. Unplug all power cords from the system or the wall outlets.
4-3 Chapter 4: Chassis Setup and Maintenance 4-3 Accessing the Hot-Swappable Drive T rays Hot-swappable drives may be removed and installed from the chassis without powering-down the system and without opening the chassis cover . Accessing and Installing Hard Drives Unlock and open the drive tray door as shown.
SC743 Chassis Manual 4-4 4-4 Insta lling Fix ed H ard Driv es in SC7 43i S eries Chassis Models Disconnecting the Chassis from the Power Source T urn off all peri pheral devices and turn off the pow er supply connected to the 1. SC743. Unplug all power cords from the system or the wall outlets.
4-5 Chapter 4: Chassis Setup and Maintenance Removing the Dummy Drive Installing the Hard Drive 1 2 1 3 4-5 Installing Hard Drives into the Drive T rays Installing Hard Drives Remove the screws from the hard drive tray and set them aside for later use.
SC743 Chassis Manual 4-6 4-6 Conguring the Storage Module Storage Module Options The storage module can congured to accomodate a variety of data storage devices such as CD, IDE, DVD, tape and oppy driv es. The c hassis may be rotated fro m a vertical tower position, to a horizontal rack mounting position to accomdate use of these devices.
4-7 Chapter 4: Chassis Setup and Maintenance Conguring the Storage Module for 5.25" Devices Remove the 5.25” driv e trays from the st orage module. 1. Remove the screws and drive tray brackets from the drive trays. 2. Install the 5.25” devices into the storage module.
SC743 Chassis Manual 4-8 Figure 4-8: Removing the Middle Chassis Fans Release T ab 4-7 Removing and Replacing the System Fans Before installing the motherboard in the chassis or accessing the motherboard after installatio n, it is necessary to remove the system fans.
4-9 Chapter 4: Chassis Setup and Maintenance Removing Re ar Chassis Fans Locate the release tab on the top of the chassis fan, at the rear of the chas - 1. sis. Push the release tab down to unlock the fan. Once the fan is unlocked, tip it forward and out of the chassis.
SC743 Chassis Manual 4-10 4-8 Removing the Air Shroud Before installing the motherboard in the chassis or accessing the motherboard after i nstallation, i t is nece ssary to r emove the air sh roud between the two s ets of system fans.
4-1 1 Chapter 4: Chassis Setup and Maintenance 4-9 Installing the Motherboard Prior to Installing the Motherboard Before the mothe rboard can be ins talled or rem oved, the midd le and rear syst em fans and the air s hroud must be r emoved, as directed in sec tions 4-6 and 4-7.
SC743 Chassis Manual 4-12 Secure the heatsink t o the motherboard a s directed by the motherboard 6. documentation. Secure the motherboar d to the chassis us ing Type A scre ws, which are 7. included in the chassis accessory kit. Replace the middle and rear system fans as directed in section 4-6.
4-13 Chapter 4: Chassis Setup and Maintenance 4-10 Installing Add-on Cards After installing the moth erboard, add-on cards such as PCI cards may be installed into the chassis. Installing Add-on Cards Locate the release tab on the top of the add-on card bracket 1.
SC743 Chassis Manual 4-14 Once the br acket is unlocked, pull the release t ab upward and remo ve the 3. bracket from the chassis. After removing the bracket from the chassis, add-on cards may be installed in 4. the bracket. Install the bracket with the newly insta lled add-on card b ack into the chass is 5.
4-15 Chapter 4: Chassis Setup and Maintenance 4-1 1 Power Supply The SC743 chassi s includes a power supply rated at either 645, 650, 760 or 865 W atts. In the unlikely event that you need to replace the power supply , simply follow the directions for your specic power supply below .
SC743 Chassis Manual 4-16 Install the replacement power supply in the chassis. 4. Replace the screws which were set aside previously . 5. Replace any other components in the chas sis that have been removed and 6. replace the chassis cover bef ore replacing the p ower cord and powe ring up the system.
4-17 Chapter 4: Chassis Setup and Maintenance 4-12 A ccessin g th e Int erior Sp ace B etween t he Backplane and the Midplane For easy access to the interior space between the backplane and the midplane, follow the instructions below before installing components or cables into this area.
SC743 Chassis Manual 4-18 4-13 S CSI (Supe r) G EM D river Ins tallati on In structi ons for Windows OS Note: This driver is not necessary for other operating systems.
4-19 Chapter 4: Chassis Setup and Maintenance Installing the Driver (Alternative Procedure) Right click the “My Computer” icon on your desktop and choose Properties. 1. Click on the 2. Hardware tab and select Device Manager to bring up the list of system devices.
SC743 Chassis Manual 4-20 Notes.
5-1 Chapter 5: Rack Installation Chapter 5 Rack Installation 5-1 Overview This chapter provi des a quick setup chec klist to get your cha ssis up and runnin g. Following these steps in the order given should enable you to have the system operational in a minimal amount of time.
SC743 Chassis Manual 5-2 This product is for installation only in a Restricted Access Location (dedicated • equipment rooms, service closets and similar environments). Rack Precautions Ensure that the leveling jacks o n the bottom of the rack are f ully extende d to • the oor with the full weight of the rack resting on them.
5-3 Chapter 5: Rack Installation Rack Mounting Considerations Ambient Operating T emperature If installed in a closed or multi-unit rack assembly , the ambient operating tempera - ture of the rack en vironment may be greater than the ambi ent tempe rature of th e room.
SC743 Chassis Manual 5-4 5-4 Installing the Chassis Rack Mounting Rails Before Installing the Chassis Rails Unplug the power cord from the from the power supply .
5-5 Chapter 5: Rack Installation Installing the Outer Chassis Rails Locate the two pairs of outer ra ils. Each pair con sists of one middle rail, one 1. end bracket and one end rail as shown. Figure 5-2: Assembling the Outer Chassis Rails Insert the end bracke t and the end rail onto the m iddle rail and sec ure them 2.
SC743 Chassis Manual 5-6 Figure 5-3: Mounting the Chassis into a Rack Inner Rails Outer Rail Assemblies.
A-1 Appendix A: Chassis Cables Appendix A Cables, Screws, and other Accessories A-1 Overview This appendi x lists sup ported cab les for yo ur chassis system.
SC743 Chassis Manual A-2 SC743i Series Part # T ype Length Description CBL-0087 Cable 20" Round 16-pin to 16-pin front panel ribbon cable CBL-0084 Cable 6" Split converter cable CBL-0209L Cable 8.26" (210mm) 4-pin to 3-pin fan power cable CBL-0216L Cable 8.
A-3 Appendix A: Chassis Cables Extending Power Cables Although Supermicro chassis are designed with to be efcient and cost-effective, some compatible motherboards have power connectors located in different areas. T o use these motherboards you may have to extend the power cables to the mother boards.
SC743 Chassis Manual A-4 A-3 Chassis Screws The accessory bo x include s all the scre ws needed to setup your chassis. This section lists and describes the most common screws used. Y our chassis may not require all the parts listed. Flat head M4 x 4 mm [0.
B-1 Appendix B: Power Supply Specications Appendix B Power Supply Specications B-1 Power Supply Options This appendix lists power supply specications for your chassis system. 465W MFR Part # PWS-465-PQ Rated AC V oltage 100 - 240V 60 - 50Hz 6 - 3 Amp +5V standby 3 Amp +12V 35 Amp +5V 20 Amp +3.
SC743 Chassis Manual B-2 760W MFR Part # PWS-0056 Rated AC V oltage 100 - 240V 50 - 60Hz 14- 8 Amp +5V standby 3.5 Amp +12V 50.0 Amp +5V 36.0 Amp +3.3V 36.0 Amp -12V 1.0 Amp 865W MFR Part # PWS-865-PQ Rated AC V oltage 100 - 240V 50 - 60Hz 12- 6 Amp +5V standby 6.
C-1 Apppendix C: CSE-M34S/CSE-M34T Mobile Rack Specications Appendix C CSE-M34S/CSE-M34T Mobile Rack Specications C-1 Overview T h i s m a n u a l i s w r i t t e n f o r s y s t e m i n t e g r a t o r s , P C t e c h n i c i a n s a n d knowledgeab le PC u sers.
SC743 Chassis Manual C-2 C-3 Packing List The C SE- M3 4S /CSE- M3 4T mob ile rac k provi des the f ollow ing: CSE-M34S/CSE-M34T mobile rack • 90mm exhaust fan • Drive carrier four (4)CSE-PT.
C-3 Apppendix C: CSE-M34S/CSE-M34T Mobile Rack Specications Additional Information The CS E- M3 4S /CSE -M 3 4 T m obile rack was designed for use in certain chas sis and servers or as a stand alone unit. Use the chassis or server manual for instal - lation instructions.
SC743 Chassis Manual C-4 C-4 Front Connectors and Jumpers Figure C-1. Mobile Rack Backplane (Front) Jumper Settings Jumper settings for the CSE-M34S (SCSI) JP18 JP21 JP24 JP14 JP25 Jumper Description .
C-5 Apppendix C: CSE-M34S/CSE-M34T Mobile Rack Specications JP18 Buzzer Reset Closed: Enable Open: Disable (default) JP25 Overheat T empera- ture Open: 45 degrees Celcius 1-2: 50 degrees Celcius 2-.
SC743 Chassis Manual C-6 Jumper Settings and Locations for the CSE-M35T (SA T A) JP18 JP25 Channel #2 � Channel #3 � Channel #4 � Channel #1 � JP28 ACT2 ACT3 ACT4 COM K e y JP26 ACT1 Activity LEDs Pin Denitions JP26 Act. LED1 = Channel 1 Act.
C-7 Apppendix C: CSE-M34S/CSE-M34T Mobile Rack Specications Installation Procedures Installing the CSE-M35S Backplane SCSI IDs are assigned automatically by the backplane. 1. Do not set IDs man - ually on the drives. See the previous section for SCSI ID jumper settings.
SC743 Chassis Manual C-8 Installing a Drive into the Drive Tray Mount the drive in the drive tray . 1. Secure it into the drive tray as shown with the screws provided.
C-9 Apppendix C: CSE-M34S/CSE-M34T Mobile Rack Specications Accessing the Backplane Remove the screws loc ated on the back of the mobile rack u nit as shown 1. Pull out the rear fan bracket 2. Remove the screws securing the backplane. 4. Remove the backplane.
SC743 Chassis Manual C-10 Notes.
D-1 Apppendix D: CSE-M35S/CSE-M35T1 Mobile Rack Specications Appendix D CSE-M35S/CSE-M35T1 Mobile Rack Specications D-1 Overview Su perm icr o’s CSE- M35S /CS E-M3 5T1 M obil e Rac k Se ries o ffers c utt ing edg e technology with greater exibility .
SC743 Chassis Manual D-2 D-3 T echnical Specications Occupancy Three (3) 5.25" drive bays • Capacity Five (5) SCA Ultra 320/160 hard drives with SAF-TE • built-in (CSE-M35S only) Five (5) .
D-3 Apppendix D: CSE-M35S/CSE-M35T1 Mobile Rack Specications JP29 JP21 JP30 JP18 JP24 Pin 1 Pin 1 Pin 1 Pin 1 Pin 1 Figure D-1: Jumper Locations (SCSI) D-4 Jumper Settings Jumper Settings for the C.
SC743 Chassis Manual D-4 Jumper Settings for the CSE-M35T1 (SA T A) Mobile Rack Location of Jumpers Key JP26 Ac tivity LED s- P in D e f in it ions Ac t.
D-5 Apppendix D: CSE-M35S/CSE-M35T1 Mobile Rack Specications D-5 Installing the Hard Drive For the CSE-M35S SCSI IDs are assigned automatically by the backplane. Do not set IDs manu - 1. ally on the driver . Se the previous section for SCSI ID jumper settings.
SC743 Chassis Manual D-6 Pull out the hard drive. 3. Place the hard drive into a drive tray . 4. Insert the screws through the mounting holes and into the hard drive.
D-7 Apppendix D: CSE-M35S/CSE-M35T1 Mobile Rack Specications D-6 Removing the Exhaust Fan Squeeze the two tabs located on both sides of the exhaust fan as shown: 1. Gently pull the fan away from the back of the mobile storage rack. 2. Note: For the SC942 Chassis, the CSE-M35 Rear Exhaust Fan should not be used.
SC743 Chassis Manual D-8 D-7 Removing the Backplane Remove the screw located on the side of the storage module as shown. 1. Pull the rear bracket out of the storage module.
D-9 Apppendix D: CSE-M35S/CSE-M35T1 Mobile Rack Specications Remove the backplane. 3. 3 Figure D-10: Removing the Backplane.
SC743 Chassis Manual D-10 Notes.
E-1 Appendix E: SAS-743TQ Backplane Specications Appendix E SAS-743TQ Backplane Sepcications T o avoid personal injury and property damage, carefully follow all the safety steps listed below when accessing your system or handling the components.
E-2 SC743 Chassis Manual E-3 An Important Note to Users All images and layouts shown in this user's guide are based upon the latest PCB • revision available at the t ime of publishing. The card you have received may or may not look exactly the same as the graphics shown in this manual.
E-3 Appendix E: SAS-743TQ Backplane Specications 1 1 +12V +12V GND GND GND GND +5V +5V 48 1 16 64 49 H12 H7 H4 M71 M75 M86 M87 H5 H6 H3 M90 M91 M96 M97 MM2 MM3 SAS743TQ REV 3.00 R S UPER pb 4 Jumper Settings and Pin Denitions E-4 Front Connectors and Jumpers Front Connectors 1.
E-4 SC743 Chassis Manual E-5 Front Connector and Pin Denitions #5. Activity LED Header The activity LED header , designated JP26, is u sed t o in dic ate t he acti vit y stat us of each SAS drive. The Activ ity LED Header is located on the front panel.
E-5 Appendix E: SAS-743TQ Backplane Specications #6 and 9. Sideband Headers The sideband headers are de signated JP 51 and JP52. For SES-2 to work properly , you must connect an 8-p in side band ca ble. S ee the table to the right for pin denitions.
E-6 SC743 Chassis Manual E-6 Front Jumper Locations and Pin Denitions +12V +12V GND GND GND GND +5V +5V 48 1 16 64 49 H12 H7 H4 M71 M75 M86 M87 H5 H6 H3 M90 M91 M96 M97 MM2 MM3 SAS743TQ REV 3.
E-7 Appendix E: SAS-743TQ Backplane Specications Explanation of Jumpers T o modify the operation of the backplane, jumpers can be u sed to choose between optional settings. Jumpers create shorts between two pins to change the funct ion of the connecto r .
E-8 SC743 Chassis Manual I 2 C and SGPIO Mode Jumper Settings This backplane can utilize I 2 C or SGPIO. I 2 C is the default mo de and can be used without makin g changes to yo ur jumpers . The following informati on details which jumpers must be congured to use SGPIO mode or restore your backplane to I 2 C mode.
E-9 Appendix E: SAS-743TQ Backplane Specications SAS Port Connections in I 2 C a nd SGP IO Set tings Use the follow ing chart when conn ecting th is backp lane. If yo u connect the SAS ports out of order , you will not able to easily identify drives using the LED func - tion.
E-10 SC743 Chassis Manual +12V +12V GND GND GND GND +5V +5V 48 1 16 64 49 H12 H7 H4 M71 M75 M86 M87 H5 H6 H3 M90 M91 M96 M97 MM2 MM3 SAS743TQ REV 3.00 R S UPER pb OH/DRIVE F AIL LED Front Panel LEDs L.
E-1 1 Appendix E: SAS-743TQ Backplane Specications E-7 Rear Connectors and LED Indicators Rear SAS/SA T A Connectors Rear Connector SAS Drive Number SAS #0 SAS/SA T A HHD #0 SAS #1 SAS/SA T A HHD #.
E-12 SC743 Chassis Manual Disclaimer (cont.) The products sold by Supermicro are not intended for and will not be used in life sup- port systems, medical equipment, nuclear facilities or systems, airc.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Supermicro SuperChassis 743TQ-R760 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Supermicro SuperChassis 743TQ-R760 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Supermicro SuperChassis 743TQ-R760 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Supermicro SuperChassis 743TQ-R760 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Supermicro SuperChassis 743TQ-R760, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Supermicro SuperChassis 743TQ-R760.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Supermicro SuperChassis 743TQ-R760. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Supermicro SuperChassis 743TQ-R760 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.