Manuale d’uso / di manutenzione del prodotto SLBV-35PM del fabbricante Superior
Vai alla pagina of 28
SLBV-35NE SLBV-40NE SLBV-35NM SLBV-35PM SLBV-40NM SLBV-40PM ITS Report No. 100017854 Please read and understand these instructions BEFORE starting installation. MODELS I N S T A L L A T I O N I N S T R U C T I O N S B-Vent Gas Fireplaces SLBV 35/40 Models MILLIVOL T : ELECTRONIC: P/N 506009-02 Rev .
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S Packaging ......................................... Page 2 Introduction ...................................
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S Note: Installation and repair should be done by a qualified ser vice person. The appliance should be inspected before use and at least annually by a professional ser vice person.
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S Figure 2 - Dexen Electronic Gas Valve Pilot Stage T ermi.
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S COLD CLIMA TE INSULA TION For cold climate installations, seal all cracks around your appliance with noncombustible material and wherever cold air could enter the room.
T ermination Heights For V ents Above Flat Or Sloped Roofs Ref. NFP A 54 / ANSI Z223.1 Roof Pitch * F ee t * M e t e r s Flat to 6/12 1.0 0.3 6/12 to 7/12 1.25 0.38 7/12 to 8/12 1.5 0.46 8/12 to 9/12 2.0 0.61 9/12 to 10/12 2.5 0.76 10/12 to 11/12 3.25 0.
5 ( 1 27 ) 8-1/4 ( 2 09 ) 14 ( 3 56 ) 12 ( 3 05 ) 19 ( 48 3) 8 (203) 2 ( 51 ) 4 ( 10 2 ) 6 ( 15 2 ) 8 ( 20 3 ) 10 ( 25 4 ) 12 ( 30 5 ) 10 (254) 14 (356) 18 (457) 16 (406) 12 (305) T op of Appl iance inches (millimeters) Mant el Dep th No te - H ood sh own as po sit ion ed.
PRE-INST ALLA TION STEPS (Remove Glass Enclosure Panel) The appliance is shipped with all gas controls and components installed and pre-wired. Note: Remove the glass enclosure panel before installing the fireplace. T o remove the glass enclosure panel: 1.
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S FIREPLACE AND FRAMING SPECIFICA TIONS NO TE: Diag ram s, i llus tra tion s an d ph otog raph s a re n ot t o s cale .
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S VERTICAL VENTING THROUGH CEILING Frame Ceiling Opening: T o locate the center of the vertical run, use a plumb line from the ceiling above the appliance.
Note: • All appliances are factory-equipped with a ex ible gas line con nector and 1/2 inc h shutof f valve (se e Figure 17 on Page 15 ) . • See Massac husetts Requi rements on Pa ge 4 for additional requirements for installa- tions in the state of Massachusetts in the USA.
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S 12 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Step 4. Install Field Wiring CAUTION Ground supply lead must be con- nected to the wire attached to the green ground screw located on the outlet box.
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S 13 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 12 MILLIVOL T WIRING DIAGRAM CAU TION : WH EN S ERVI CING CON TROL S, LA BEL ALL WIRE S PR IOR TO D ISCO NNECT ION.
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S Step 5.
S U PE R I O R ® B- V E N T G A S F I R E PL A C E S • MO D E L S S L B V - 35 , S LB V -4 0 • I N ST A L L A TI O N IN S T R UC T I O NS Figure 17 Step 6. Connect the Gas Line All codes require a shut-off valve mounted in the supply line. The orientation of the shut- off valve should face the front.
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S T urn on gas supply and test for gas leaks, us - ing a gas leak test solution (also referred to as bubble leak solution).
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S W ARNING • DO NOT attempt to install the logs until the appliance installation has been completed, the gas line connected and tested for leaks and the initial burner operation has been checked out.
S U PE R I O R ® B- V E N T G A S F I R E PL A C E S • MO D E L S S L B V - 35 , S LB V -4 0 • I N ST A L L A TI O N IN S T R UC T I O NS SLBV-35 LOG PLACEMENT INSTRUCTIONS Figure 23 Left Rear Brackets Step 1 Right Rear Bracket Glowing Embers (Do not place Glowing Embers over burner slots.
SLBV-40 LOG PLACEMENT INSTRUCTIONS Figure 24 Left Rear Log Right Rear Log Ember Chunk Left Front Log Right Front Log 5 4 2 3 1 SLBV Firebox Accessories/Parts Cat.
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S Only doors certified with the appliance shall be used. Seules des portes certifiées pour cet appareil doivent être utilisées.
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S Main Burner Factory Air Shutter Opening Setting - Inches (millimeter) Model Nat.Gas Propane Gas S LBV -35 1/ 32 (0.
pull the switch/bracket assembly (with low voltage wires attached) through the side panel slot into the rebox. 8 - Replace the switch, if necessar y .. 9 - Reinstall the scoop and lintel. 10 - Reinstall the glass enclosure panel and control compartment access panel.
Step 12. Install Hood NOTE: All models must have a hood installed prior to operating. Refe r to Figure 30 . Instal l hood by sliding it into the slots on the lower edge of the cabinet top . Step 13. Finishing Requirements Wall Details Complete finished interior wall.
S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S 24 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE.
Millivolt SIT Systems Propane Gas to Natural Gas Conversion Kits Models Catalog No. SLBV-35 H8271 SLBV-40 H7675 Millivolt SIT Systems Natural Gas T o Propane Gas Conversion Kits Models Catalog No. SLBV-35 H8270 SLBV-40 H7673 Electronic DEXEN Systems Propane Gas T o Natural Gas Conversion Kits Models Catalog No.
Electronic Appliances Ste p 8. Dexen Electronic V alves: Refer to Figure 34 and the instructions pro- vided with the kit. a. Remove and discard the two pres- sure regulator mounting screws. b. Remove the pressure regulator and diaphragm. c. Discard all removed components.
Notes S U PE R I O R ® B -V E N T G A S FI R E P LA C E S • M OD E L S S L B V - 3 5, S L BV -4 0 • I N S T A L L A TI O N IN S T R UC T I O N S 27 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE.
Printed in U.S.A. © 2010 Lennox Hearth Products P/N 506009-02 Rev . B 06/2011 Lennox Hearth Products reser ves the right to make changes at any time, without notice, in design, materials, specications, prices and also to discontinue colors, styles and products.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Superior SLBV-35PM è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Superior SLBV-35PM - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Superior SLBV-35PM imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Superior SLBV-35PM ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Superior SLBV-35PM, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Superior SLBV-35PM.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Superior SLBV-35PM. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Superior SLBV-35PM insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.