Manuale d’uso / di manutenzione del prodotto B-40RMP del fabbricante Superior
Vai alla pagina of 16
1 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INST ALLA TION INSTRUCTIONS ST ANDARD SERIES 36" B-VENTED GAS APPLIANCES P/N 700,003M REV. H 05/2004 Millivolt Models Electronic Models B-40RMN B-40REN B-40RMP B-40REP RET AIN THESE INSTRUCTIONS FOR FUTURE REFERENCE WH Report No.
2 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. TABLE OF CONTENTS Introduction ..................................... page 2 General Information ......................... page 2 Location .......................................... page 3 Clearances .
3 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning are similar to the flu with headaches, dizziness and/or nausea.
4 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Venting Gas Vent Rule – Gas vent caps are not permit- ted within 8 feet (2.4 mm) of a vertical wall or similar obstruction.
5 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. A 38 ¹⁄₂ " 978 mm B 33 ³⁄₄ " 857 mm C 28 ³⁄₁₆ " 716 mm D 14" 356 mm E 55" 1397 mm F 27 ¹⁄₂ " 699 .
6 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 10 Note: Refer to the vent manufacturers installa- tion instructions for variations of venting tech- niques. If common venting of several units is contemplated, it should be discussed with an architect and the local Building Department.
7 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 13 Figure 14 Figure 12 Figure 15 Secure all joints tightly using appropriate tools and sealing compounds (ensure propane resis- tant compounds are used in propane applica- tions). Turn on gas supply and test for gas leaks using a soapy water solution.
8 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. WARNING: DO NOT REMOVE THE AC- TUATOR ARM LOCKING SCREW UNLESS THE COMPLETE OUTSIDE AIR VENT SYS- TEM HAS BEEN INSTALLED IN ACCOR- DANCE WITH THE DETAILED INSTRUC- TIONS PROVIDED WITH THE KIT.
9 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 19 Figure 20 When first lighting the appliance, it will take a few minutes for the line to purge itself of air. Once purging is complete, the pilot and burner will light and operate as indicated in the in- struction manual.
10 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. When satisfied that the appliance operates prop- erly, proceed to finish the installation. Leave the control knob/lever in “ ON ” position and turn the remote switch “ OFF. ” Replace the refractory access panel.
11 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. INSTALLATION ACCESSORIES The following accessory items are available for use in the installation of this appliance. Outside Air Kits Models FOAK-4 and FOAK-4LD Outside Air kits are available with duct (FOAK-4) and without duct (FOAK-4LD) for use if outside combustion air is required or desired.
12 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. In Canada THE CONVERSION SHALL BE CARRIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HAVING JURISDICTION AND IN ACCORDANCE WITH THE REQUIREMENTS OF THE CAN1-B149.1 AND .2 INSTALLATION CODE.
13 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Figure 29 Pilot Orifice Step 6. All Millivolt Systems – Attach ma- nometer to the manifold side pressure test fitting and verify manifold pressure reads 3.5 inches water column (0.87 kPa) for natural gas, and 10.
14 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE..
15 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE..
16 NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. Printed in U.S.A. © 2002 by Lennox Hearth Products P/N 700,003M REV. H 05/2004 LHP 1110 West Taft Avenue • Orange, CA 92865 The manufacturer rese.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Superior B-40RMP è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Superior B-40RMP - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Superior B-40RMP imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Superior B-40RMP ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Superior B-40RMP, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Superior B-40RMP.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Superior B-40RMP. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Superior B-40RMP insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.