Manuale d’uso / di manutenzione del prodotto Vienna del fabbricante Strong Pools and Spas
Vai alla pagina of 16
OWNER’S MANUAL 3204 Point T ownship Drive (Rte 1 1) • P .O. Box 108 Northumberland, P A 17857 1-800-STRONG-9 1-800-787-6649 ™ 1/8/07 CAUTION: More than one GFCI used on the electrical circuit will render this spa inoperable. This spa must be on a dedicated circuit.
T able of Contents Introduction ................................................................................................................................. 1 Health Safety .........................................................................
Introduction 1 The V ienna Spa Please use this space to record the pertinent information about your new spa here: Date of Purchase: ________/________/_______ Color: _________________________________ Serial # Yo ur Strong Spas Spa Serial Number is located on the Control Pack box panel.
2 Spas are known for their helpful qualities such as hydrotherapy and arthritic relief. But spas are not only a toy , there are several health concerns which the owner must be aware of such as the following: W ARNING People with infectious diseases should not use a spa.
3 Spa Location: Improper installation may result in equipment damage and will void the warranty . Y our spa must be placed on a flat, level surface. The space you choose to install your spa is a very important decision, you should consider all of the listed suggestions.
Electrical - General Instructions 4 220V V ienna Electrical Connections: Three W ire & Ground These wires go to the PC Board Control Circuit. TERMINAL BLOCK GRD L1 L2 N It is recommended that a li.
Control Panel Identification 5 Mode Mode key will change your spa - 3 different modes 1. Standard - Normal spa usage 2. Economy - Maintains temperature slightly lower than desired 3. Sleep - Keeps temperature approximately 20º below set temperature for inactive use Mode is changed by pushing warm of cool keys with mode key .
6 Startup Preparations - Make sure that if spa is equipped with gate valves, that valves are opened. (These gate valves are easily noticed in your access area by the distinct “T” shaped handle.) - When filling your spa remove the filter , and place hose into filter area.
7 Changing Filter Cycles T roubleshooting No power to spa: 1. Check proper connection of to pack 2. Check fuse in pack. 3. Must have very good ground connection - If none call tech support T rips Breaker: 1. Make sure dedicated line: 2. Check breaker 3.
8 T roubleshooting continued from previous page Problem: No message on display . Power has been cut off to spa. Solution: The control panel will be disabled until power returns. Spa settings will be preserved until next power up. Problem: T emperature unknown.
9 Problem: A significant difference between temperature sensors has been detected. This could indicate a flow problem. Solution: Check water level in spa. Refill if necessary . If water level is okay , make sure the pumps have been primed. If problem persists, contact your dealer or service organiza- tion.
10 The maintenance and care of your spa is simple and easy to carry out, and if performed regularly as scheduled, problems will be minimal. It is important that the following proce- dures be read through and carried out on a regular basis for the best, long term, overall performance of your spa.
11 CONCENTRA TED CHLORINA TING GRANULES - The minimum chlorine level in the spa should be at least 2PPM (parts per million). Chlorine level should be tested frequently and the chemical added to maintain a safe level of 2PPM. This type of chemical can be added in quantities of 0.
12 For current update changes on warranties, consult our website at www .strongspas.com W ARRANTIES Spa Structure: 10 years Strong Spas warrants the original retail purchaser the structural integrity of the spa shell against water loss due to defects in material or workmanship for as long as the customer shall own the spa.
FOR YOUR RECORDS: For future use, it is advisable that you write down some information pertaining to the model of the spa you have purchased. If you are unsure of the model name, frame size, etc., contact your dealer immediately to acquire the information needed.
RET AIN THIS BOOKLET FOR FUTURE REFERENCE: FOR ANY MISSING P ARTS, PROBLEMS OR QUESTIONS CALL: MONDA Y THROUGH FRIDA Y 8:30 AM - 5:00 PM E.S.T . (570) 275-2700 • GIVE YOUR NAME • TELEPHONE NUMBER (AREA CODE) • NAME OF SP A • NAME OF MODEL • QUANTITY AND TYPE OF P ARTS • REASON FOR REQUEST A.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Strong Pools and Spas Vienna è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Strong Pools and Spas Vienna - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Strong Pools and Spas Vienna imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Strong Pools and Spas Vienna ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Strong Pools and Spas Vienna, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Strong Pools and Spas Vienna.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Strong Pools and Spas Vienna. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Strong Pools and Spas Vienna insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.