Studio 22 B a l a n c e d F l u e Instructions for Use, Installation and Servicing For use in GB, IE (Great Britain and Eire) PR1014 Issue 4 (December 2008) IMPORTANT Do not attempt to burn rubbish in this appliance. This appliance must only be operated with the glass door secured firmly in position.
2 COVERING THE FOLLOWING MODEL: STUDIO 22 BALANCED FLUE: 8704BFLEC P8704BFLEC PAGE APPLIANCE COMMISSIONING CHECKLIST 3 USER INSTRUCTIONS 4 INSTALLATION INSTRUCTIONS 9 Technical Specifications 9 Site R.
3 FLUE CHECK PASS FAIL 1. Flue is correct for appliance 2. Flue flow test N/A 3. Spillage test N/A GAS CHECK 1. Gas soundness & let by test 2. Standing pressure test mb 3. Appliance working pressure (on High Setting) mb NB All other gas appliances must be operating on full 4.
4 USER INSTRUCTIONS 1. GENERAL 1.1 A competent person must carry out installation and servicing. 1.2 In all correspondence, please quote the appliance type and serial number, which can be found on the data badge located on a plate under the access panel, see Diagram 2, Installation.
5 USER INSTRUCTIONS • Pressand holdthe DOWNarrow todecrease to minimum At the lowest point the fire goes to 'standby mode' (only pilot lit) Note: While pressing a button, a symbol indicating transmission appears on the display.
6 USER INSTRUCTIONS EMERGENCY SHUT OFF If the batteries fail during use of the fire, move the switch to theOFF (O) position,Diagram 3 (Thisswitch is setto beON duringnormal operationand mustremain ON) 3 AR1933 3.
7 USER INSTRUCTIONS 7 AR1932 5. ARRANGEMENT OF FUEL BED ADVICE ON HANDLING AND DISPOSAL OF FIRE CERAMICS The fuel effect and side panels in this appliance are made from Refractory Ceramic Fibre (RCF), a material which is commonly used for this application.
8 6. FLAME FAILURE DEVICE 6.1 This is a safety feature incorporated on this appliance which automatically switches off the gas supply if the pilot goes out and fails to heat the thermocouple.
9 INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION COVERING THE FOLLOWING MODELS: STUDIO 22 BF: 8704BFLEC P8704BFLEC Model Gas CAT. Gas Type Working Pressure Nox Class Aeration Injector Gas Rate m 3 /h Input kW (Gross) Country High Low 8704BFLEC I 2H Natural Gas (G20) 20 mbar 4 5 x 16 mm 530 0.
10 INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION This appliance has been certified for use in countries other than those stated. To install this appliance in these countries, it is essential to obtain the translated instructions and in some cases the appliance will require modification.
11 INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION Steel Frame Dimensions Dimension: Size (mm) A 1350 B 675 C 846 D 320 E 177 F 237 G 25 ProlFrameDimensions Dimension: Size (mm) A 1036 B 510 C 940 D 414 E 48 F 48 G 12.
12 INSTALLATION INSTRUCTIONS SITE REQUIREMENTS Note: This appliance must only be installed with the flue supplied. You must adhere to the following: 1.
13 2. FLUE OPTIONS REAR EXIT (8708) • Cut tolength asrequired onsite 1 AR0630 200 mm min 500 mm max Guard Supplied. TOP EXITS 2.1 TOP FLUE UP & OUT KIT (8534) This flue is vertical from the top of the appliance then horizontally out.
14 INSTALLATION INSTRUCTIONS SITE REQUIREMENTS 2.3 TOP FLUE VERTICAL KIT (8524/8524AN) Vertical from the top of the appliance (See Diagram 4). 4 AR1673 A minimum vertical rise 3m (9’10") to a maximum 10m (32’10").
15 INSTALLATION INSTRUCTIONS SITE REQUIREMENTS 5. APPLIANCE LOCATION 5.1 Please note this appliance has been specifically designed for studwork applications although installation into other constructions, including masonry, is entirely feasible. There are two methods of installation, see Installation Instructions 3.
16 INSTALLATION INSTRUCTIONS INSTALLATION IMPORTANT: REFER TODATA BADGEAND TECHNICAL SPECIFICATIONAT THE FRONTOF THEMANUAL TO ENSURE THEAPPLIANCE ISCORRECTLY ADJUSTEDFOR THEGAS TYPE ANDCATEGORY APPLICABLEIN THE COUNTRYOF USE.
17 INSTALLATION INSTRUCTIONS INSTALLATION 2.5 You can now remove the burner: • Undothe fourscrews holdingthe burnertray inplace • Removethe burner • Liftthe left-handside upand out 4 AR2117 2.
18 INSTALLATION INSTRUCTIONS INSTALLATION 3. STUD WORK INSTALLATION THERE ARE THREE TYPES OF INSTALLATION INTO STUDWORK DESCRIBED IN THE FOLLOWING PAGES: 1) FOR STUDIO 22 WITH EITHER THE STEEL, PROFIL.
19 INSTALLATION INSTRUCTIONS INSTALLATION • Fitthe supportbar intothe studworkat thecorrect height, Diagram 11. 11 AR1904 • Attachthe 4frame.
20 INSTALLATION INSTRUCTIONS INSTALLATION 15 AR2134 • Put verticalstudwork atminimum clearanceto theside of the fire (50mm) • Secure to.
21 INSTALLATION INSTRUCTIONS INSTALLATION 6. STUDWORK FOR COOL WALL INSTALLATION KIT Thereis an optionalStudio 22Cool WallInstallation Kitavailable for installing the fire without a frame: Studio 22 BF Code No. 8727BFCW22.
22 INSTALLATION INSTRUCTIONS INSTALLATION • Fitnon-combustible boardto thestudwork abovethe fire. This should extend a minimum of 400mm above the appliance and a minim.
23 INSTALLATION INSTRUCTIONS INSTALLATION 8.1 REAR EXIT FLUE WALL THICKNES S MIN 200mm MAX 600mm 8.1.3 Remove the flue assembly and terminal guard from the box.
24 8.2.2 The appliance is factory set for top exit. 8.3 A 152mm (6") diameter hole in the wall or ceiling is required to install the flue. This can be achieved by either: a) Core drill b) Hammer and chisel • Drillsmall holesaround thecircumference whenusing method b.
25 INSTALLATION INSTRUCTIONS INSTALLATION 9.3 Remove the screw from the pressure test point • Connecta suitablepressure gaugeto thetest point located on the inlet f.
26 40 AR2124 A D 10.6 Put the groovein thebase ofLog Einto theindent onthe rightof Log A.The leftbranch restson theupper endof Log C, Diagram 41. 41 AR2125 A E 10.
27 INSTALLATION INSTRUCTIONS INSTALLATION 11. LIGHTING THE STUDIO Note: The Emergency Shut Off switch must be in the ON position, refer to Section 2, User Instructions.
28 2 AR1936 Oncethe handsethas a newcode, thecontrol boxneeds to be reprogrammed: To access the control box, see Servicing Instructions, Section 7 - Main Control Assembly . • Pressand holdthe resetbutton onthe controlbox until you hear two signals.
29 SERVICING INSTRUCTIONS SERVICING / FAULT FINDING CHARTS 1. SERVICING REQUIREMENTS This appliance must be serviced at least once a year by a competent person.
30 SERVICING INSTRUCTIONS FAULT FINDING CHARTS IGNITION FUNCTIONAL CHECK 2 NOSPARK Ensure there is no debris around the pilot assembly, (e.g. soot etc.) which could short the spark, clean the area. Consult the users instructions, retry. From Ignition Fault Finding Chart 1 Is the gap between electrode and thermocouple 4.
2 AR2119 3.2 To completely remove the glass front: • Openthe doorat aright angleto thefire • Liftthe doorvertically offits hingesand placeto one side, Diagram 3 3 AR2137 • Refitin reverseorder • Refitin reverseorder 4.
32 SERVICING INSTRUCTIONS REPLACING PARTS 5. VERMICULITE PANELS 5.1 TAKE CARE WHEN HANDLING THE VERMICULITE PANELS, THEY ARE FRAGILE. Note: Make sure you support the back panel before removing the sec.
33 9 AR1888 10 AR2135 Withall screws removed: • Slidethe controlunit tothe left • Liftthe right-handside upand out 11 AR2128 7.
34 SERVICING INSTRUCTIONS REPLACING PARTS 13 AR1349 • Replacewith anew electrode.Do notover-tighten the nut; this could break the component • Replacethe ignitionlead bypushing thespade connector onto the terminal (electrode) 14 AR1874 A B 8.
35 SERVICING INSTRUCTIONS REPLACING PARTS 11. MAGNETIC SAFETY VALVE 11.1 To replace the magnetic safety valve: • Undothe thermocouplefrom the interrupterblock and.
36 SERVICING INSTRUCTIONS REPLACING PARTS 16. PRESSURE AND LEAK TESTING THE APPLIANCE 16.1 Follow Section 7, Main Control Assembly: • Accessto the pressuretest pointcan nowbe reached, Diagram 19 19 AR2130 16.
37 SERVICING INSTRUCTIONS REPLACING PARTS STUDIO 22 COMPONENT NG LPG PILOT INJECTOR PI0069 PI0070 MAININJECTOR IN0050 IN0051 BURNER ASSEMBLY GZ5501 GZ5510 AERATION PLATE G20- GZ3269 G30.
38 SERVICE RECORDS 1ST SERVICE Date of Service:........................................................................... Next Service Due:....................................................................... Signed:................................
Gazco Limited, Osprey Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7JG Tel: (01392) 261999 Fax: (01392) 444148 E-mail: info@gazco.com A member of the Stovax Group.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Stovax Studio 22 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Stovax Studio 22 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Stovax Studio 22 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Stovax Studio 22 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Stovax Studio 22, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Stovax Studio 22.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Stovax Studio 22. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Stovax Studio 22 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.