Manuale d’uso / di manutenzione del prodotto CD12 del fabbricante Stanley Black & Decker
Vai alla pagina of 22
© 2014 Stanley Black & Decker , Inc. New Britain, CT 06053 U.S.A. 62379 8/2014 V er . 4 USER MANUAL Safety , Operation and Maintenance CD12 Hydraulic Core Drill.
.
CD12 User Manual ◄ 3 SERVICING: This manual contains safety , operation, and routine maintenance instructions. Stanley Hydraulic T ools recommends that servicing of hydraulic tools, other than routine maintenance, must be performed by an authorized and certied dealer .
4 ► CD12 User Manual Always observe safety symbols. They are included for your safety and for the protection of the tool. LOCAL SAFETY REGULA TIONS Enter any local safety regulations here. Keep these instructions in an area accessible to the operator and mainte- nance personnel.
CD12 User Manual ◄ 5 T ool operators and maintenance personnel must always comply with the safety precautions given in this manual, and on the stickers and tags attached to or on the tool and hose(s). These safety precautions are for your safety . Review them carefully before operating the tool or performing any maintenance or repairs.
6 ► CD12 User Manual SAFETY T AG P/N 15875 (Shown smaller then actual size) DANGER DANGER READ OPERA TION MANUAL AND SAFETY INSTRUCTIONS FOR THIS TOOL BEFORE USING IT . USE ONL Y P ARTS AND REP AIR PROCEDURES APPROVED BY ST ANLEY AND DESCRIBED IN THE OPERA TION MANUAL.
CD12 User Manual ◄ 7 The rated working pressure of the hydraulic hose must be equal to or higher than the relief valve setting on the hy- draulic system. There are three types of hydraulic hose that meet this requirement and are authorized for use with Stanley Hydraulic T ools.
8 ► CD12 User Manual Oil Flow Hose Lengths Inside Diameter USE ( Press/Return) Min. Working Pressure GPM LPM FEET METERS INCH MM PSI BAR Certied Non-Conductive Hose - Fiber Braid - for Utility Bu.
CD12 User Manual ◄ 9 Flow Range Nominal Operating Pressure (at the power supply outlet) System relief valve setting (at the power supply outlet) Maximum back pressure (at tool end of the return hose) Measured at a max. uid viscosity of: (at min. operating temperature) T emperature: Sufcient heat rejection capacity to limit max.
10 ► CD12 User Manual GENERAL OPERA TION The tool comes with a set of accessories which may be customized by each purchaser , so as to facilitate per- formance of all work occurring within the scope of his specic application. T ools included are for mounting and dismounting.
CD12 User Manual ◄ 1 1 DRILLING WITH CD12 ANCHOR ST AND The anchor stand may be used with a vacuum pump for a vacuum hold down or with a concrete anchor screw to hold the stand in place while drilling. The standard ar- rangement of the anchor stand is for use with a vacuum pump.
12 ► CD12 User Manual 12. NO TICE Manually screw the corresponding drill bit from below onto the drill bit adapter . Manual tightening is sufcient because the drill bit will automatically tighten further during the drilling operation. Connect the core drill to a water supply .
CD12 User Manual ◄ 13 ANCHOR ST AND TROUBLESHOOTING Symptom Cause Solution The Anchor Stand will not hold a vacuum. Debris under the base gasket is preventing a good seal. Clean the surface on which the gasket must seal. Debris between the base gasket and the base.
14 ► CD12 User Manual • Make sure all couplers are wiped clean before con- nection. • The hydraulic circuit control valve must be in the OFF position when coupling or uncoupling hydrau- lic tools. Failure to do so may result in damage to the quick couplers and cause overheating of the hy- draulic system.
CD12 User Manual ◄ 15 When diagnosing faults in operation of the grinder , always check that the hydraulic power source is supplying the correct hydraulic ow and pressure to the grinder as listed in the table. Use a owmeter known to be accurate.
16 ► CD12 User Manual Problem Cause Solution Fluid gets too hot. Circuit relief set too low . Adjust relief valve to 2100-2250/145- 155 bar . T oo much uid going through tool. Adjust ow for 6 gpm/23 lpm maximum. Circuit has contaminants that have caused wear and high heat genera- tion.
CD12 User Manual ◄ 17 System T ype .................................................................................................................................... HTMA T ype II OC Flow Range .....................................................
18 ► CD12 User Manual CD12 P ARTS ILLUSTRA TION.
CD12 User Manual ◄ 19 ITEM P ART NO. QTY DESCRIPTION 6531 1 MOTOR ASSEMBL Y 101 65207 1 MOT OR HOUSING 102 41254 1 OUTPUT SHAFT 103 41255 1 SPUR GEAR 104 41256 1 SHAFT SEALING 105 41257 1 SNAP RING .
20 ► CD12 User Manual CD12 ANCHOR ST AND ILLUSTRA TION.
CD12 User Manual ◄ 21 ITEM P ART NO. QTY DESCRIPTION 1 65214 1 HANDLE 2 65215 1 ST OP PLA TE 3 65216 2 HSH CAPSCREW 4 65217 4 HSFH SCREW 5 65218 1 CLAMP PLA TE 6 65219 1 DRILL ST AND COLUMN 7 65220 .
Stanley Hydraulic T ools 3810 SE Naef Road Milwaukie, Oregon 97267-5698 USA (503) 659-5660 / Fax (503) 652-1780 www .stanleyhydraulics.com.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Stanley Black & Decker CD12 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Stanley Black & Decker CD12 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Stanley Black & Decker CD12 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Stanley Black & Decker CD12 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Stanley Black & Decker CD12, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Stanley Black & Decker CD12.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Stanley Black & Decker CD12. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Stanley Black & Decker CD12 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.