Manuale d’uso / di manutenzione del prodotto Marley Aquatower del fabbricante SPX Cooling Technologies
Vai alla pagina of 12
/ Mar le y A quat o w e r ® Cooling T ower /.
2 / The Aquat ow er Adv antag e / ■ Proven Performance. CTI Certified. Plus SPX stands by its responsibility for r eliable thermal per formance. We designed it.
3 / The Mar ley Dif f er ence / T oday’ s Aquatower may be the most space/energy- efficient cooling tower available. Y our needs have dictated constant technological improvement. Thousands of Aquatower users enjoy the benefits of eight major redesigns and dozens of minor improvements in the past 40 years.
4 SIDE ELEV A TION AIR INLET ELEV A TION 1. Nominal tons are based upon 35°C HW , 29.5°C CW , 25.5°C WB and .68 m 3 /hr per ton. The Marle y UPD A TE web-based selection sof t ware provides Aquato wer model recommendations based on specific design requirements.
5 1. Use this bulletin for preliminary layouts only . Obtain current draw- ings fr om your Marley sales repr esentative or your local distribu- tor . 2. Purchaser to provide tower suppor ts complete with holes and bolts for anchorage. All supports must be framed flush and level at top.
6 / Constr uction And Components / ■ Water Distribution System W arm water flows through external piping (not included with the tower) into a splash box chamber at the top of the Aquatower . A splash box prevents the incoming water from spilling out of the basin and helps provide uniform water distribution.
7 / Constr uction And Components / ■ Mechanical Equipment Belt-driven propeller fans insur e design airflow at minimum power . Fans are supported by an oil-lubricated tapered r oller bearing assembly with remote oil r eservoir . For ease of maintenance all drive components are accessible from outside the tower .
8 / F r eeze Pr evention / When the ambient air temperature falls below 0°C, the water in a cooling tower can freeze. Marley T echnical Report #H-003 “Operating Cooling T owers in Freezing Weather” describes how to prevent fr eezing during operation.
9 / Field Assembly / 1. Maximum m 3 /hr applies to both pump and gravity flow piping sys- tems. The outlet piping on gravity flow systems must have sufficient vertical drop to overcome all other head losses in the system. 2. Bottom outlet is not available on Models 490A and 490B.
10 / Options / V er tical Discharge Hood This option is available on Models 494A and larger . It provides vertical discharge of the air leaving the tower . Hoods are galvanized steel. They ship separately for installation by others. A large ac- cess door provides entry to the fan and mechanical equipment.
11 Base: Furnish and install an induced-draft, crossflow , factory- assembled, steel cooling tower of ____ cell(s), as shown on plans. T ower shall be similar and equal in all respects to Marley Series 4900 Aquatower , Model _______. T ower must be warranted by the manufacturer for one year from date of shipment.
SPX CO OLI NG TEC H N OL OG I ES U K L TD.. G R EGO RY'S BAN K WOR CESTE R WR3 8AB U N ITE D KI NG DO M +44 (0) 1905 7 20 200 info.uk@spx.com spxcooling.com In the i nterest o f tec hnologic al progre ss, all products are subject to design and/or material change without notice.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il SPX Cooling Technologies Marley Aquatower è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del SPX Cooling Technologies Marley Aquatower - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso SPX Cooling Technologies Marley Aquatower imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul SPX Cooling Technologies Marley Aquatower ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il SPX Cooling Technologies Marley Aquatower, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del SPX Cooling Technologies Marley Aquatower.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il SPX Cooling Technologies Marley Aquatower. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo SPX Cooling Technologies Marley Aquatower insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.