Manuale d’uso / di manutenzione del prodotto ICX418ALB del fabbricante Sony
Vai alla pagina of 20
– 1 – E01908A41 Sony reserves the right to change products and specifications without prior notice. This information does not conv ey an y licens e by any implication or otherwise under any patents or other right. Application circuits shown, if an y , are typical e xamples illustr ating the operation of the de vices.
– 2 – ICX418ALB USE RESTRICTION NO TICE (December 1, 2003 ver .) This USE RESTRICTION NO TICE ("Notice") is for customers who are considering or currently using the CCD products ("Products") set f or th in this specifications book.
– 3 – ICX418ALB Block Dia gram and Pin Configuration (T op View) Pin Description Pin No . Pin No . 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Symbol Description V φ 4 V φ 3 V φ 2 φ SUB V φ 1 V L .
– 4 – ICX418ALB Absolute Maximum Ratings Item Substrate cloc k φ SUB – GND Supply v oltage Clock input v oltage V oltage diff erence between vertical clock input pins V oltage diff erence betwe.
– 5 – ICX418ALB DC Characteristics Output circuit supply current Item I DD Symbol 5.0 Min. Unit Remarks T yp . Max. mA 10.0 Bias Conditions 1 [when used in substrate bias internal generation mode].
– 6 – ICX418ALB Clock V oltage Conditions ∗ 1 Input the reset gate clock without applying a DC bias . In addition, the reset gate clock can also be driv en with the fo llowing specifications .
– 7 – ICX418ALB Horizontal transfer c lock equivalent cir cuit V er tical transfer c lock equiv alent circuit H φ 1 H φ 2 C φ H1 C φ H2 C φ HH V φ 1 C φ V12 V φ 2 V φ 4 V φ 3 C φ V34 C .
– 8 – ICX418ALB Drive Clock W aveform Conditions (1) Readout cloc k waveform (2) V er tical transfer cloc k wavef orm V VH = (V VH1 + V VH2 )/2 V VL = (V VL3 + V VL4 )/2 V φ V = V VH n – V VL n.
– 9 – ICX418ALB (3) Horizontal transfer cloc k waveform (4) Reset gate cloc k waveform V RGLH is the maximum v alue and V RGLL is the minimum v alue of the coupling wa vef or m during the per iod from P oint A in the abov e diagram until the rising edge of RG.
– 10 – ICX418ALB Clock Switc hing Characteristics ∗ 1 When vertical transfer cloc k dr iver CXD1267AN is used. ∗ 2 tf ≥ tr – 2ns. ∗ 3 The ov er lap period for twh and twl of horizontal transf er clocks H φ 1 and H φ 2 is two . Min. two T yp .
– 11 – ICX418ALB Image Sensor Characteristics Item Sensitivity Saturation signal Smear Video signal shading Dark signal Dark signal shading Flick er Lag Symbol S Ysat Sm SH Vdt ∆ Vdt F Lag Min. 880 1000 Ty p . 1100 –115 Max. –105 20 25 2 1 2 0.
– 12 – ICX418ALB Image Sensor Characteristics Measurement Method Measurement conditions 1) In the f ollowing measurements, the de vice dr iv e conditions are at the typical values of the bias and clock voltage conditions . (when used with substrate bias e xter nal adjustment, set the substrate v oltage to the v alue indicated on the device .
– 13 – ICX418ALB 5. Dark signal Measure the av erage value of the signal output (Vdt [mV]) with the de vice ambient temperature 60°C and the de vice in the light-obstructed state, using the horizontal idle transf er le vel as a ref erence.
– 14 – ICX418ALB Drive Circuit 1 (substrate bias internal generation mode) 22/16V 0.01 –9V 3.3/16V 3.3/20V 0.01 1/35V 1 100 H φ 1 H φ 2 φ RG RD GND NC V DSUB NC 22/20V CCD OUT [ ∗ A] 15V XSUB XV2 XV1 XSG1 XV3 XSG2 XV4 H φ 2 H φ 1 RG 100k 0.
– 15 – ICX418ALB Drive Circuit 2 (substrate bias e xternal adjustment mode) 22/16V 0.01 –9V 3.3/16V 3.3/20V 0.01 1/35V 0.1 100 H φ 1 H φ 2 φ RG RD GND NC V DSUB NC 22/20V CCD OUT [ ∗ A] 15V XSUB XV2 XV1 XSG1 XV3 XSG2 XV4 H φ 2 H φ 1 RG 27k 0.
– 16 – ICX418ALB Spectral Sensitivity Characteristics (Excludes lens characteristics and light source characteristics) Sensor Readout Clock Timing Chart Unit: µs Odd Field Even Field V1 V2 V3 V4 V1 V2 V3 V4 2.5 2.5 2.5 2.5 33.5 1.6 0.2 1.0 0.8 0.
– 17 – ICX418ALB Drive Timing Chart (Vertical Sync) 520 525 1 2 3 4 5 10 15 20 493 494 260 265 270 275 280 494 493 2 1 4 3 6 5 2 1 4 3 6 5 FLD VD BLK HD V1 V2 V3 V4 CCD OUT 13 5 24 6 135 24 6.
– 18 – ICX418ALB Drive Timing Char t (Horizontal Sync) 760 768 1 2 3 5 10 20 30 40 1 2 3 5 10 20 22 1 2 3 1 2 3 10 20 HD BLK H1 H2 RG V1 V2 V3 V4 SUB.
– 19 – ICX418ALB Notes on Handling 1) Static charge prev ention CCD image sensors are easily damaged by static discharge . Before handling be sure to tak e the follo wing protectiv e measures. a) Either handle bare handed or use non-chargeable glov es, clothes or material.
– 20 – ICX418ALB P acka ge Outline Unit: mm Sony Corporation 16 pin DIP (300mil) 1st. pin Index H V 6.175 12.0 ± 0.15 12.35 ± 0.3 φ 13.2 ± 0.3 1.84 1.5 1.5 0.7 1.5 3.29 ± 0.3 2.54 7.62 0.25 4.0 4.0 4.0 ± 0.2 1.0 0.3 1.27 0.6 1.84 1 8 9 16 6.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Sony ICX418ALB è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Sony ICX418ALB - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Sony ICX418ALB imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Sony ICX418ALB ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Sony ICX418ALB, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Sony ICX418ALB.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Sony ICX418ALB. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Sony ICX418ALB insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.