Manuale d’uso / di manutenzione del prodotto 19A SERIES del fabbricante Smith Cast Iron Boilers
Vai alla pagina of 12
19IOM-5 WESTCAST, INC. 260 NORTH ELM STREET WESTFIELD, MA 01085 TEL. (413) 562-9631 FAX (413) 562-3799 INST ALLER READ THESE INSTR UCTIONS CAREFULL Y .
PAGE 2 19A SERIES BOILER INST ALLA TION INSTRUCTIONS — 3640 Bur ner Mounting Plate, P o werflame - 9 1 / 8 " Opening 13 60023 Bur ner Mounting Plate Rope, 1 / 4 " 14 60434 Bur ner Mounting.
3. CODES AND REGULATIONS All work in connection with the boiler, burner and controls must be performed in strict accordance with requirements of state and local authorities having jurisdiction over boiler installations. FIGURE 1 In the absence of such local requirements, the following should govern: A.
CAUTION Due to the fact that the sections are top heavy, it is absolutely necessary that the back section be supported in such a manner as to prevent its falling and causing potential serious bodily injury while preparing to add the next section. One such way would be to insert a piece of 3" x 36" piping in the lower port.
2. Water Boilers – The assembled boiler shall be subjected to a hydrostatic test pressure not less than 1-1/2 times the maximum allowable working pressure. 3. The required test shall not exceed the test pressure by more than 10 PSI. Excessive torque on draw rods may damage castings.
TABLE 5 Feed water makeup requirements. NOTE These recommendations are considered normal for compact buildings on the basis of 80% receiver use. Where buildings are spread out, additional receiver capacity may be necessary because of the extended time required for condensation to return to the receiver.
FIGURE 6 — TANKLESS PIPING FIGURE 7 — DUAL TANKLESS PIPING 12. BURNER MOUNTING PLATE & TARGET WALL The new target wall used on 3-6 section boilers must be positioned with the flat side tight against the rear casting and with the bottom side resting on the floor of the combustion chamber.
19A SERIES BOILER INST ALLA TION INSTRUCTIONS PAGE 8 15. CONTROL LOCATIONS NOTE Jacket front panel should be in place before controls on front of front section are installed. Refer to FIGURE 11 showing locations recommended for steam and water boiler limit and operating controls.
19A SERIES BOILER INST ALLA TION INSTRUCTIONS 19. OWNERS INSTRUCTIONS A . For best performance of the boiler, the following suggestions should be performed by a qualified boiler room technician, through a regular program of maintenance and adjustment to obtain the following.
19A SERIES BOILER INST ALLA TION INSTRUCTIONS FIGURE 11 PAGE 10 “A” - 1" TAP, PRESSURE CONTROLS “B” - 1 1/4" TAP, STEAM SAFETY VALVE “C” - 1" TAP, OPTIONAL LWCO “D” - 3/4" TAP “A” “B” VENT CONNECTION 3/4" TAP STD.
19A SERIES BOILER INST ALLA TION INSTR UCTIONS vision problems loss of muscle control weakness dizziness headaches nausea W ARNING shortness of breath unclear thinking unconsciousness Any appliance that burns natural gas, propane gas, fuel oil, wood or coal is capable of producing carbon monoxide (CO).
WESTCAST, INC. 260 NORTH ELM STREET WESTFIELD, MA 01085 TEL. (413) 562-9631 FAX (413) 562-3799.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Smith Cast Iron Boilers 19A SERIES è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Smith Cast Iron Boilers 19A SERIES - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Smith Cast Iron Boilers 19A SERIES imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Smith Cast Iron Boilers 19A SERIES ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Smith Cast Iron Boilers 19A SERIES, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Smith Cast Iron Boilers 19A SERIES.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Smith Cast Iron Boilers 19A SERIES. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Smith Cast Iron Boilers 19A SERIES insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.