Manuale d’uso / di manutenzione del prodotto ASH-13AK del fabbricante Sinclair
Vai alla pagina of 49
SER VICE MANU AL KING SERIES AS H - 09 A K , AS H - 1 3A K.
.
Model Remarks ASH-09AK ASH-13AK 1 Summary and features Summary and features 09/1 3 Outdoor unit: 1Ph 220~240V 50Hz R410a.
CO O LI NG HEA T I NG CO O LI NG HEA T I NG 2650 / 9050 2850/ 9730 3516/ 12000 4015/ 13700 820 785 1080 1104 1110 1150 1 500 1500 5. 69 5. 9 7. 6 7. 6 M odel of I ndoor Unit Fan M o tor Spe ed (r/ m i.
ASH-09AK ASH-13AK H IGH L Y Gre e A SG 102CV -B 7A T Q X A - 133uB 030 Rot ary Ro t o r y 18A 32 4. 05 5.1 875 1160 K A - 172- LY G N914 B 250- 150-141 E -5 ~43 -15 ~46 77 1-1.
Part name Part name Wall Pipe LED displayer Remote control window Guide louver Indoor unit Outdoor unit Front Panel Filter Air in Air out Drainage hose Air in Air out Manual switch Wireless remote con.
Tube exit Air inlet Rear View Right Left Ceiling Wall-Mounting Plate W D H Outline and installation dimensions of indoor unit 4 Outline and installation dimension Outline and installation dimension Wa.
Outline and installation dimensions of outdoor unit Unit:mm ASH-09AK , ASH-13AK Bolt Nut Wrench over over over over.
Electrical circuit diagram Electrical circuit diagram 5 5 5 5 5 ASH-09AK ASH-13AK.
6 6 6 6 6 Manual of functions of remote controller and operation method Manual 1 of functions of remote controller 6.1.1 Temperature parameter The room setting temperature(Tpreset) The room ambient temperature (Tamb) 6.
T preset +2 ℃ T preset -2 ℃ T amb Compressor Outdoor fan Indoor fan Cooling D ry S t op 6 min . 6 min . 4 min. 4 min. low speed Run S t op 6.1.2.2.
3.Other controls 1. Memory function Memory contents: Mode, up and down swing, Light, Setting temp., Setting fan speed, Ordinary setting Fahrenheit/Centigrade, after powered off, and powered on, it will run at the memory contents.
(6) Turbo function The turbo function is available in Cool and Heat modes. (7) Dry function Dry function is available in Cool and Dehumidifying modes. (8) Auto fan speed control In this mode, indoor fan can run with Hig, Mid, Low speeds.
Manual 2 of functions of remote controller 1 . Temperature parameter The room setting temperature(Tpreset) The room ambient temperature (Tamb) Basic Functions Once energized, the compressor should in no way be restarted unless after 3-minute time interval at least for the first energization, the compressor will be started without 3-minute lag.
DRY Modes When T amb. Tpreset 2 , the unit will run under DR Y cooling mode, in which case the compressor and outdoor fan will be started and the indoor fan will run at low speed.
Other controls Timer function Ordinary Timer setting: timer on: Under unit off, the timer on function could be set up, if timer on has arrived, controller will run at setting mode, the timer interval is 0.
Turbo function The turbo function is available in Cool and Heat modes. Dry function Dry function is available in Cool and Dehumidifying modes. Auto fan speed control In this mode, indoor fan can run with Hig, Mid, Low speeds.
D is sa ss em bl y Pr oc ed ur es Front Pane (09) Disassembly procedures for indoor unit 1. Disassemble the front panel, fi lter Filter Bend the g uide louver so th at t he m ovable lock of gu ide louver is release d to remove the gui de louv er.
Operating Procedures / Photos Sc rew off the scr ew, the n pr ess t he c las ps i n by till they loose, then lift up wards the electric cover . 4. Disassemble the electric cover 5.
Operating Procedures / Photos Screw off 4 screws fixing the motor cover and then take the motor cover out. Screw off the holding screw at the left shaft sleeve of the cross flow fan, pull out the motor, and re- move the cross flow fan. 7. Disassembling motor and cross flow fan 6.
Op en the fr on t p ane l , Pu sh t he fi lte r u pw ard s t o unloo se the clasp, an d then pull out the two filter s. Front Pane (12) Disassembly procedures for indoor unit 1. Disassemble the front panel, f ilter Filter Bend the g uide louver so th at t he m ovable lock of gu ide louver is release d to remove the gui de louv er .
Operating Procedures / Photos Press the clasps in by till they loose, then lift up wa r ds the elec tric cov er. 4. Disassemble the electric cover 5. Disassemble water tray Elect ric cove r 5.
Operating Procedures / Photos Screw off 4 screws fixing the motor cover and then take the motor cover out. Screw off the holding screw at the left shaft sleeve of the cross flow fan, pull out the motor, and re- move the cross flow fan.
Push the rotating shaft of front panel out wards to unloose the clasp, and then pull out the front panel . Front Panel (Conventional 09) Disassembly procedures for indoor unit 1. Disassemble the front panel, filter Filter Bend the guide louver so that the movable lock of guide louver is released to remove the guide louver.
Operating Procedures / Photos Screw off the screw, then press the clasps in by till they loose, then lift up wards the electric cover and the light board.
Operating Procedures / Photos Screw off 4 screws fixing the motor cover and then take the motor cover out. Screw off the holding screw at the left shaft sleeve of the cross flow fan, pull out the motor, and re- move the cross flow fan. 8. Disassembling motor and cross flow fan 7.
Front Panel (Conventional 12) Disassembly procedures for indoor unit 1. Disassemble the front panel, filter Filter Bend the guide louver so that the movable lock of guide louver is released to remove the guide louver.
Operating Procedures / Photos 4. Disassemble the Light Board and electric cover 6. Disassemble water tray Electric cover 5. Disassemble the electric box Lossen the grounding wire of the evaporator, re- move the tube sensor and temp sensor support, put out the connection lines for the step motor and the indoor motor.
Operating Procedures / Photos Screw off 4 screws fixing the motor cover and then take the motor cover out. Screw off the holding screw at the left shaft sleeve of the cross flow fan, pull out the motor, and re- move the cross flow fan.
(09/12) Disassembly Procedures for Outdoor Unit Operating Procedures / Photos Unscrew the screw fixing the big handle,and then remove it downwards to take it out. Screw Unscrew the 2 screws fixing left side of top cover and the 1 screw fixing the right side to remove the top cover.
Operating Procedures / Photos Unscrew the 5 screws fixing the panel and dextrorotate the front panel to pull it out from groove. Unscrew the 2 screws fixing electric box ,and then unscrew the 5 screws fixing the right side plate to remove it. 4. Disassemble Front Panel 6.
Operating Procedures / Photos Loosen the fastening nut fixing the axial flow fan with a spanner, and then take out the nut, spring gasket and flap gasket in turn. Axial Flow Fan Unscrew the 4 screws fixing the motor to take out the motor,and then unscrew the 2 screws fixing the motor support to take it out.
Operating Procedures / Photos Respectively unsolder the weld spots of main capillary and auxiliary capillary to take off the capillary. 10. Disassemble Capillary 1 1. Disassemble Gas and Liquid V alves Unscrew the two bolts fixing gas valve and liquid valve.
9 9 9 9 9 Failure and analysis The breaker trips at once when it is set to "ON". Measure insulation resistance to ground to see if there is any leakage. Trip of breaker or blow of fuse The breaker trips in few minutes when it is set to "ON" Check power supply circuit.
Improper set of temperature Adjust set temperature If cooling (heating) load is proper Check the forecasted load of cooling (heating) The refrigerant has leakage or is insufficient heck and fill the l.
The indoor fan motor is burned or breaks or has the heat protector malfunction. Replace the fan motor or the defective part. The built-in heat protector of the motor breaks frequently because the motor is abnormal. Replace the fan motor Wrong connection Make the correction connection based on the circuit drawing.
Wrap of refrigerant pipe joint is not close enough. Re-wrap and make it tight. Water leakage Fan of indoor unit contacts other parts. Adjust fan location. Foreign object in indoor unit T ake out the foreign object. Compressor shakes too much. Adjust support washer of compressor, and tighten loosen screws.
PG motor locked protection H6: Probable reasons: 1. Air vents were blocked which may cause the fan speed is too slow; 2. Fan blade locked; 3. Motor locked; 4.
P ARTS GUID E AS H - 09 A K , AS H - 1 3A K KING SERIE S.
.
Contents 04..………………………………….......................................................ASH-09AK Indoor unit 06..…………………………………………………………………...…ASH-13AK Indoor unit 08..………………………………………………………………….
Explosive view and spare parts list of indoor unit ASH-09AK.
Part code Date 1 Wall-Mounting Frame 01252220 1 2 Rear Case 222020572 1 3 Evaporator Pipe Cover 06122001 1 4 Drainage Pipe 05230014 1 5 Pipe Clamp 24242004 1 6 Cross Flow Fan 10352001 1 7 Fan Bearing .
Explosive view and spare parts list of indoor unit ASH-13AK.
Part code Date 1 Wall-Mounting Frame 0125221701 1 2 Rear Case 22202451 1 3 Drainage Pipe 05230014 1 4 Cross Flow Fan 10352012 1 5 Fan Bearing 76512210 1 6 Ring of Bearing 76512206 1 7 Decoration Plate.
Explosive view and spare pa rts list of outdoor unit ASH-09AK.
Part code Date 1 Front Grill 22413431 1 2 Axial Flow Fan 10333004 1 3 Front Plate 01533012 1 4 Metal Base 01203622P 1 5 4-way rever -sing valve compon e 03023792 1 6 4-way valve 43000402 1 7 4-way val.
Explosive view and spare pa rts list of outdoor unit ASH-13AK.
Part code Date 1 Front Grill 22413431 1 2 Nut M6 70310131 1 3 Axial Flow Fan 10333004 1 4 Front Plate 01533012 1 5 Metal Base 012032292 1 6 4-way Valve 430004032 1 7 4-way Valve Coil 43000400 1 8 Comp.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Sinclair ASH-13AK è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Sinclair ASH-13AK - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Sinclair ASH-13AK imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Sinclair ASH-13AK ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Sinclair ASH-13AK, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Sinclair ASH-13AK.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Sinclair ASH-13AK. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Sinclair ASH-13AK insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.