Manuale d’uso / di manutenzione del prodotto ID-DS0711-S1 del fabbricante Siig
Vai alla pagina of 20
1 Introduction The 2-Port RS-232/422/485 Serial over IP Ethernet Device Server is designed to operate serial ports over 10/100 Mbps Ethernet networks, transmitting via TCP/IP protocol. Features and Benefits • ARM Cortex-M3 32-bit high performance CPU • Auto reset on Idle detection • Easy to use Web Server Management • 115.
2 RS-232/422/ 485 (Port 2) RS-232 (Port 1) DC-In (power) LAN Reset Button LED Indicators (SYS, Port-2, Port-1) Package Contents • 2-Port RS-232/422/485 Serial over IP Ethernet Device Server • Powe.
3 Device Server Configuration Follow the instructions below to configure your Serial over IP Ethernet Device Server , if needed. The default IP address of the Serial over IP Ethernet Device Server is 192.
4 4. Click the Modify MAC button and change the MAC address from the prompted Dialog Frame window, if needed. 5. Click the Web Browse button to open the Web Browser Configuration webpage. See Figure 6. Figure 4 1. Double click IP Search Utility in the included software CD, then double click CVBrowser.
5 Type in password and click the Login button, then make your changes from the Web Browser Configuration webpage. See the section for more information. Web Console Configuration In addition to basic IP address and subnet mask, specific device settings can be set through HTTP protocol with popular browsers, e.
6 • Firmware version : The Serial over IP Ethernet Device Server's firmware version is identified by date code. • Serial number : Product serial number as provided by the factory • Ethernet.
7 • Subnet mask : Subnet mask of 255.255.255.0 is usually used for small networks, 255.255.0.0 for larger networks. If your IP address is provided by an ISP or network administrator, please obtain that information and enter it correctly.
8 Figure 8 • Serial I/O Port 1 (RS-232) : One RS-232 serial port for connecting RS-232 serial device • Serial I/O Port 1 (RS-422/485) : One RS-422/485 serial port for connecting RS-422/485 serial device • Local Port : A socket port assigned to the serial port.
9 • Interface - Port 1 - RS232 GTxD, RxD for data stream, no flow control - RS232 (RTS/CTS) GTxD, RxD for data stream, RTS/CTS for flow control • Interface - Port 2 : The Auto Detect feature will .
10 Device Server Updated Press the Update button after you complete your changes. The Serial over IP Ethernet Device Server will save all setting into internal non-volatile memory and then reboot. The Web Console webpage will refresh in around 5 seconds.
11 COM Port Setup IMPORTANT : Copy the VirtualCOM folder from your driver CD to your PC's hard drive, then follow the instructions below to add the virtual COM port. 1. Open the VirtualCOM folder, double click 32-bit or 64-bit folder ( based on your system), then double click VSerPortConsole .
12 4 . Click Install this driver anyway or Continue Anyway , then a COM port would be assigned. 5. Right click under the assigned COM port and click Add Net . Figure 12 COM 3 Add Net 6. Type in the IP address of the Serial over IP Ethernet Device Server in the Remote Address field.
13 8. A (Unconnceted) TCP Client... will be established. Figure 14 (Unconnected) TCP Client... 9. Right click on the Virtualserial Port Console , click Add Port , then follow steps 3-7 to add the second serial port, if needed. 10. Close the Virtualserial Port Console and reopen it to make sure the COM port is successfully added.
14 Figure 15 Enter a terminal name, choose an icon, and press OK button. Figure 16.
15 Figure 17 Sele ct the assigned COM port at the Connect using field, see Figure 17 . For example, if the virtual COM port was assigned COM 3, then select COM 3. Figure 18 Select the same values with the Controller Setup to the COMX Properties , then click OK .
16 If Hyper Terminal connects with the Serial over IP Ethernet Device Server successfully, the time clock at the lower left corner, Connected hh:mm:ss , will start counting, see Figure 19 . Figure 19 H yper Terminal for COM Port Initiate another Hyper Terminal as a COM Port Terminal.
17 Wiring Architecture PC Ethernet switch / hub RS-232 RS-232 (RTS / CTS) LAN cable Serial Device Rx Tx GND RTS CTS Serial to TCP/IP Tx Rx GND CTS RTS Serial Device Rx Tx GND Serial to TCP/IP Tx Rx GN.
18 FAQ Q1 . Why can't ETM.exe detect the Serial over IP Ethernet Device Server on the network? A1 . Please check the followings: (1) The power adapter is properly connected and powerd on ; (2) Th.
19 Technical Support and Warranty QUESTIONS? SIIG ’ s Online Support has answers! Simply visit our web site at www.siig.com and click Support . Our online support database is updated daily with new drivers and solutions. Answers to your questions could be just a few clicks away.
About SIIG, Inc. Founded in 1985, SIIG, Inc. is a leading manufacturer of IT connectivity solutions (including Serial ATA and Ultra ATA Controllers, FireWire, USB, and legacy I/O adapters) that bridge the connection between Desktop/ Notebook systems and external peripherals.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Siig ID-DS0711-S1 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Siig ID-DS0711-S1 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Siig ID-DS0711-S1 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Siig ID-DS0711-S1 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Siig ID-DS0711-S1, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Siig ID-DS0711-S1.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Siig ID-DS0711-S1. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Siig ID-DS0711-S1 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.