Sigma K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels Operation and Maintenance Manual Sigma K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels Operation and Maintenance Manual Issue 04 Sept.
Sigma K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels Operation and Maintenance Manual CONTENTS Contents .......................................................................................................... Page Safety & Installation ..
Sigma K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels Operation and Maintenance Manual IMPOR T ANT READ THIS SECTION FIRST! 1.1 Suppliers of articles for use at work are required under section 6.
Sigma K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels Operation and Maintenance Manual 3 . 1 Enable Controls No Controls are enabled unless the enable controls key is inserted. While the enable controls key is inserted the buzzer will beep every few seconds.
Sigma K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels Operation and Maintenance Manual Page 4 of 10 FRONT P ANEL INDICA TIONS - Continued 4 . 2 System Fault Indicator The system fault indicator will illuminate under any abnormal condition.
Sigma K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels Operation and Maintenance Manual 6.1 The panel has an internal DIL Switch, which provides the following functions:- INTERNAL INDICA TORS SOUNDER S/C F AUL T 1234 5 6 SOUNDER O/C F AUL T FUSE F AUL T EAR TH F AUL T REM.
Sigma K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels Operation and Maintenance Manual Page 6 of 10 Smoke Detection Circuits 7.1 One to six smoke detection circuits are provided and supply 28 V olts ( + 5%) for the operation of trigger devices, (smoke detectors or heat detectors).
Sigma K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels Operation and Maintenance Manual Page 7 of 10 Remote Alarm Input 11.1 The sounder circuits may be operated remotely via the remote alarm input. 11.2 The input is labelled (Rem AL I/P) Connection of the AUX common negative to this point will operate the sounders.
Sigma K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels Operation and Maintenance Manual Page 8 of 10 ANNEXE 2.
Sigma K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels Operation and Maintenance Manual ANNEXE 3 Resistor monitoring wiring. Standard bases are used. Removal of a detector indicates fault but detectors beyond the removed one will be inoperative. Line continuity unit wiring.
Sigma K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels Operation and Maintenance Manual Page 10 of 10 ANNEXE 4 K1006 PCB layout - 4 & 6 zone Sigma, fuse & option resistor locations K1002 .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Sigma K1000 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Sigma K1000 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Sigma K1000 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Sigma K1000 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Sigma K1000, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Sigma K1000.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Sigma K1000. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Sigma K1000 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.