Sentry MODBUS I/O Memory Map March 4, 2005 Page : 1 Sentry Controller MODBUS Memory Map Detail 1 All Registers are MODB US 16 bit registers 2 There are five different ways of using M ODBUS registers ( see italic reference number in left colu mn for each address ) 2.
Sentry MODBUS I/O Memory Map March 4, 2005 Page : 2 Read Only Parameters Modbus Address Parameter Units FIX EGU Discrete 40001:0 High alarm bi ts - sensor 1 40001:1 High alarm bi ts - sensor 2 40001:2.
Sentry MODBUS I/O Memory Map March 4, 2005 Page : 3 Modbus Address Parameter Units FIX EGU 40007:0 High alarm relay lat ched – sensor 1 40007:1 High alarm relay lat ched – sensor 2 40007:2 High al.
Sentry MODBUS I/O Memory Map March 4, 2005 Page : 4 Modbus Address Parameter Units FIX EGU 40020:0 Sensor 1: Status 2 Sensor Disconnected (Trouble Bits) 40020:2 Sensor 1: Voltage Re gulator Failure 40.
Sentry MODBUS I/O Memory Map March 4, 2005 Page : 5 Modbus Address Parameter Units FIX EGU 40040:0 Sensor 3: Sensor Disconnected (Trouble Bits) 40040:2 Sensor 3: Voltage Regul ator Failure 40040:3 Sen.
Sentry MODBUS I/O Memory Map March 4, 2005 Page : 6 Modbus Address Parameter Units FIX EGU 40060:0 Sensor 5: Sensor Disconnected (Trouble Bits) 40060:2 Sensor 5: Voltage Regul ator Failure 40060:3 Sen.
Sentry MODBUS I/O Memory Map March 4, 2005 Page : 7 Modbus Address Parameter Units FIX EGU 40080:0 Sensor 7: Sensor Disconnected (Trouble Bits) 40080:2 Sensor 7: Voltage Regul ator Failure 40080:3 Sen.
Sentry MODBUS I/O Memory Map March 4, 2005 Page : 8 Analog Process Variables Modbus Address Parameter Units FIX EGU 40111 Sensor 1 concentration % / PPM 0 - 6553.5 40112 Sensor 2 concentration % / PPM 0 - 6553.5 40113 Sensor 3 concentration % / PPM 0 - 6553.
Sentry MODBUS I/O Memory Map March 4, 2005 Page : 9 Modbus Address Parameter Units FIX EGU 40156 Sensor 6 Power (H 2 S and COMB only ) 40157 Sensor 7 Power (H 2 S and COMB only ) 40158 Sensor 8 Power .
Sentry MODBUS I/O Memory Map March 4, 2005 Page : 10 Modbus Address Parameter Units FIX EGU 40224 Sensor 1 Input Value - Multiplex 0 0 - 6553.5 40225 Sensor 1 Input Value - Multiplex 1 0 - 6553.5 40226 Sensor 1 Input Value - Multiplex 2 0 - 6553.5 40227 Sensor 1 Input Value - Multiplex 3 0 - 6553.
Sentry MODBUS I/O Memory Map March 4, 2005 Page : 11 Modbus Address Parameter Units FIX EGU 40266 Sensor 3 High Alarm Ti me Mont h 40267 Sensor 3 High Alarm Ti me Day 40268 Sensor 3 High Alarm Ti me H.
Sentry MODBUS I/O Memory Map March 4, 2005 Page : 12 Modbus Address Parameter Units FIX EGU 40311 Sensor 4 High Conc. Tim e Month 40312 Sensor 4 High Conc. Tim e Day 40313 Sensor 4 High Conc. Tim e Hr 40314 Sensor 4 High Conc. Tim e Min 40315 Sensor 4 Low Conc.
Sentry MODBUS I/O Memory Map March 4, 2005 Page : 13 Modbus Address Parameter Units FIX EGU 40356 Sensor 5 Input Value - Multiplex 0 0 - 6553.5 40357 Sensor 5 Input Value - Multiplex 1 0 - 6553.5 40358 Sensor 5 Input Value - Multiplex 2 0 - 6553.5 40359 Sensor 5 Input Value - Multiplex 3 0 - 6553.
Sentry MODBUS I/O Memory Map March 4, 2005 Page : 14 Modbus Address Parameter Units FIX EGU 40398 Sensor 7 High Alarm Ti me Mont h 40399 Sensor 7 High Alarm Ti me Day 40400 Sensor 7 High Alarm Ti me H.
Sentry MODBUS I/O Memory Map March 4, 2005 Page : 15 Modbus Address Parameter Units FIX EGU 40443 Sensor 8 High Conc. Tim e Month 40444 Sensor 8 High Conc. Tim e Day 40445 Sensor 8 High Conc. Tim e Hr 40446 Sensor 8 High Conc. Tim e Min 40447 Sensor 8Low Conc.
Sentry MODBUS I/O Memory Map March 4, 2005 Page : 16 Read/Write Parameters High Alarm Limits Modbus Address Parameter Units FIX EGU 40501 Sensor 1 % / PPM 0 - 65535 40502 Sensor 2 % / PPM 0 - 65535 40.
Sentry MODBUS I/O Memory Map March 4, 2005 Page : 17 40550 Sensor 4 Calib. Coeff. 1 k1 ccn ccn ccn 40551 2 k2 vmin vmax vmi n 40552 3 k3 vmax - vmax 40553 4 n1 gasfac - - 40554 5 n2 - - - 40555 6 n3 - - - 40556 7 bp12 - - - 40557 8 bp23 - - - 40558 9 ccn - - - 40560 Sensor 5 Calib.
Sentry MODBUS I/O Memory Map March 4, 2005 Page : 18 Control Bits Modbus Address Parameter Units FIX EGU 40601 System Reset 40602 Alarm Reset 40603 History Reset 40610 System Tim e Month 40611 System .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Sierra Monitor Corporation Sentry Controller Gas Detector è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Sierra Monitor Corporation Sentry Controller Gas Detector - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Sierra Monitor Corporation Sentry Controller Gas Detector imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Sierra Monitor Corporation Sentry Controller Gas Detector ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Sierra Monitor Corporation Sentry Controller Gas Detector, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Sierra Monitor Corporation Sentry Controller Gas Detector.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Sierra Monitor Corporation Sentry Controller Gas Detector. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Sierra Monitor Corporation Sentry Controller Gas Detector insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.