Digital Flow Sensor Instruction Manual PFM5 Series URL http:// www.smcworld.com Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. The descriptions of products shown in this document may be used by the other companies as their trademarks.
Safety Instructions 2 Names and Functions of Individual Parts 7 Model Indication Method 8 Mountin and Installation 10 Installation 10 Pipimg 13 Wiring 14 Error Indication 16 1 Thank you for purchasing the SMC PFM5 Series Digital Flow Sensor.
3 2 Safety Instructions The Digital Flow Sensor have in after referred to as flow sensor and this manual contain essential information for the protection of users and others from possible injury and property damage and to ensure correct handling.
5 4 Safety Instructions (continued) Perform proper functional checks and leak tests after maintenance. Stop operation when an abnormality is observed such that the flow sensor does not work properly or there is a leakage of fluid. Safety is not be assured due to unexpected malfunction.
7 6 Names and Functions of Individual P ar ts Power source display (green) : Turns on when power is supplied. Flow display (green) : Flashing interval depends on the flow value. As flow increases, flash interval is shortened. The light turns to red when rated flow is exceeded.
9 8 Model Indication Method - - - 1 2 Analog (1 to 5V) Contente Model Analog (4 to 20mA) PFM30 series Applicable model PFM31 series Output specification Option2 Nil R S No option PFM5 - - / PFM5 (S) -.
Section A P anel Mount Adapter A P anel P anel Mount Adapter B Push Inser t Brack et Section C 24 +0.5 0 A 11 10 bracket mounting • Fasten the bracket mounting screws at a clamping torque of 0.
13 12 Piping Mounting and Installation (continued) • Keep the tightening torque when piping for the female thread. • Refer to the following table for the appropriate torque values. Nominal size of screws Appropriate torque N · m Rc1/8 7 to 9 Rc1/4 12 to 14 • For one-touch fitting, insert the tube to the end so that it is not pulled off.
15 14 Mounting and Installation (continued) Wiring Body of sensor Lever Cover (Option:ZS-33-F) Lead wire connector Connection • Make connection after turning the power off. • Use a separate route when installing wire. Malfunction stemming from noise may occur if wire is installed in the same route as that of power or high-voltage cable.
16 Error Indication This function is to display error location and content when a problem or an error occurs. Error indication function If the above remedy can't recover the operation, the error needs to be investigated by SMC. Error Name System Erro Error Content Troubleshooting Error Display System error.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Sierra Monitor Corporation PF5M è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Sierra Monitor Corporation PF5M - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Sierra Monitor Corporation PF5M imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Sierra Monitor Corporation PF5M ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Sierra Monitor Corporation PF5M, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Sierra Monitor Corporation PF5M.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Sierra Monitor Corporation PF5M. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Sierra Monitor Corporation PF5M insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.