GAS MONITORS MODELS 2050-00 & 2050-10 MODELS 2060-00 & 2060-10.
Applicability & Effectivity Applicability & Effectivity Sierra Monitor Corporation 1991 T arob Court, Milpit as, CA 95035 (408) 262-661 1 (800) 727-4377 E-Mail: sierra@sierramonitor .
Table of Contents T ABLE OF CONTENTS SECTION P AGE 1.PRODUCT DESCRIPTION 1 1.1 Introduction 1 1.2 Application 1 1.3 Configuration 1 1.4 T emperature Range 2 1.5 Sensor 2 1.6 Remote Alarm 2 2. QUICK ST ART 3 2.1 Overview 3 2.2 Wiring 3 3. OPERA TION 4 3.
Instruction Manual Page: 2050/2060 Gas Monitors (5/04) 1.0 PRODUCT DESCRIPTION 1.1 Introduction The Model 2050 Ammonia and Model 2060 Refrigerant/ Halocarbon Gas Monitors are continuous duty , low cost stationary monitors for detection of high levels (50-500 PPM) of ammonia and halocarbon ("freons") refrigerant gases.
2050/2060 Gas Monitors (5/04) Page: Instruction Manual 1.4 T emperature Range The Model 2050 and 2060 have temperature compen- sated circuitry to provide stabilization in temperatures ranging from -4 o to 158 o F. However , for optimum operation the unit should be cali- brated at the normal temperature expected for the sensor location.
Instruction Manual Page: 2050/2060 Gas Monitors (5/04) 3 2.0 QUICK ST ART 2.1 Overview The Gas Sensor Module has been supplied factory calibrated and ready for immediate installation and operation. An installer familiar with installation and operation of gas detection products can use this section to begin immediate use of the monitor .
2050/2060 Gas Monitors (5/04) Page: Instruction Manual 4 3.0 OPERA TION 3.1 Introduction Under normal conditions the gas sensor module does not require operator or technician intervention.
Instruction Manual Page: 2050/2060 Gas Monitors (5/04) 4.0 ALARM CALIBRA TION 4.1 Factory Alarm Calibration The module has been factory calibrated to alarm as indicated in T able 4.1 and as marked on the cali- bration label shipped with the module. Model Time Gas cc/min 2050-XX 100 sec.
2050/2060 Gas Monitors (5/04) Page: Instruction Manual 4.4 Equipment Required The following tools and equipment will be required for calibration: - Jewelers Screwdriver - Calibration Gas - Calibration.
Instruction Manual Page: 2050/2060 Gas Monitors (5/04) 5.0 SERVICE 5.1 Sensor Replacement The gas sensor needs replacement when: - It is no longer possible to obtain correct calibration - The failed sensor alarm (oscillating red/green LED) is on - The sensor output signal is noisy , causing incorrect gas alarms.
2050/2060 Gas Monitors (5/04) Page: Instruction Manual 8 6.0 INST ALLA TION 6.1 Gas Sensor Module Locations The gas sensor module is a diffusion type sensor that should be located close to the anticipated source or destination of the gas hazard. For heavy gases such as H 2 S install the module within 24 inches of the ground.
Instruction Manual Page: 2050/2060 Gas Monitors (5/04) Figure 6.1 Interconnect W iring T able 9.
2050/2060 Gas Monitors (5/04) Page: Instruction Manual T B2- 1 N C T B 2- 2 Comm o n T B 2- 3 N O No P o we r Op e n Sensor Fail Safe O pen Al ar m Open T B2- 1 N C T B 2- 2 Comm o n T B 2- 3 N O No P o we r Op e n Sensor Fail Saf e Open Al arm O pen Tabl e 6.
Instruction Manual Page: 2050/2060 Gas Monitors (5/04) In all cases SMC’s responsibility and liability under this warranty shall be limited to the cost of the equipment.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Sierra Monitor Corporation 2050-00 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Sierra Monitor Corporation 2050-00 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Sierra Monitor Corporation 2050-00 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Sierra Monitor Corporation 2050-00 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Sierra Monitor Corporation 2050-00, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Sierra Monitor Corporation 2050-00.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Sierra Monitor Corporation 2050-00. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Sierra Monitor Corporation 2050-00 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.