R S Sharp Programmable Controller New Satellite JW20H/30H ME-NET module JW-21MN Version 2.2 Produced in April 2002 User's Manual Model name.
Thank you for purchasing the ME-NET module (JW-21MN) for the SHARP programmable controller. Read this manual thoroughly to completely familiarize yourself with the operation according to the examples. Keep this manual for future reference. We are confident that this manual will be helpful whenever you encounter a problem.
Safety Precautions Read this manual and attached documents carefully before installation, operation, maintenance and checking in order to use the machine correctly. Understand all of the machine knowledge, safety information, and cautions before starting to use.
3) Use Danger - Don't touch the terminal while the power is being supplied or you may have an electric shock. - Assemble the emergency stop circuit and interlock circuit outside of the programmable controller. Otherwise breakdown or accident damage of the machine may be caused by the trouble of the programmable controller.
ME-NET Module: JW-21MN - User's Manual - Chapter 1 Features and Functions Chapter 2 Safety Precautions Chapter 3 System Configuration Chapter 4 Name and Function of Each Part Chapter 5 Installati.
Chapter 1: Features and Functions .......................................................................... 1-1 Chapter 2: Safety Precautions ........................................................................... 2-1 to 3 2-1 Installation ......
Chapter 10: Description for Computer Link Operation ............................... 10-1 to 14 10-1 Computer link function .................................................................................................... ......... 10-1 [1] Basic commands .
12-3 Storage of error code ..................................................................................................... .......... 12-6 Chapter 13: Replacement of the JW-21MN ............................................................ 13-1 Chapter 14: Support T ools .
1-1 1 Chapter 1: Features and Functions JW-21MN is a ME-NET module for JW20/JW20H/JW30H. Using this module, you can construct an ME- NET combining various FA equipment such as personal computer and robot.
2 - 1 2 "T" jacket (insulation cover) "L" jacket (insulation cover) Chapter 2: Safety Precautions 2-1 Installation Do not install or store the JW-21MN in the following conditions.
2 - 2 2 Communication cables should be laid from the master station to the slave station one by one. Multiple wiring from one point or wiring without terminators may cause communication errors. Arrange total cable length within 1 km. Arrange branch cable line from a trunk within 400 mm.
2 - 3 2 2-3 Treatment For ventilation, holes are provided in the cabinet to prevent a temperature rise. Do not block the ventilation holes. Good ventilation is necessary. Never allow a liquid such as water and chemical solution and a metallic object like a copper wire inside the JW-21MN to avoid a possible hazard.
3 - 1 3 Chapter 3: System Configuration - An example of system configuration using the JW-21MN as a master station - An example of system configuration using some other module as a master station Slave station 01 (8) JW-21MN Master station 00 (8) JW-21MN ME-NET (64 stations max.
4 - 1 4 Station No. switch Switch 1 2 3 4 5 6 7 8 9 0 UNIT NO. Module No. switch Shield ground switch STA NO. ×1 1 2 3 4 5 6 7 8 9 0 ×10 1 2 3 4 5 6 7 8 9 0 Mode switch A B C D E F 0 1 2.
5-1 5 Turn "OFF" the power supply to the JW20/JW20H/JW30H. Set the mode switch, the termination resistance switch, and the shield ground switch on the rear side of the JW-21MN. (See page 11-2 to 11-4 for settings) - The JW-21MN cannot be installed on the expansion rack panel.
6-1 6 Chapter 6: Processing of Cables Make sure to use the qualified products shown below for cables and connectors. Cable and connector installation and changes must be performed only by specialists approved by the ME-NET bureau. Maker Mitsubishi Cable Industries,.
6-2 6 6-1 Processing cable end Applicable cable High frequency coaxial cable: ME-5C-2V Required tools Stripper for high frequency coaxial cable: CST-TM Processing procedure Blade cassette Cam wheel Re.
6-3 6 Internal conductor (annealed copper single wire) 10mm From the previous page Put a coaxial cable while remaining approximately 10 mm into the cable stripper and securely tighten the cable with the middle finger, ring finger, and little finger of your left hand in order to hold stable during turning the stripper.
6-4 6 Cut the internal conductor of the coaxial cable, which is already cut by the stripper, using a nipper etc. to the optimum dimension of 4 mm. Hold up the upper section of the screw holder with a minus driver, and open the screw holder.
6-5 6 6-2 Connector crimping procedure Required tools: Hand-held crimping tool Connector: ME-GP-01 Processing procedure Connector parts Shell Sleeve Contact Contact A:10 ± 0.
6-6 6 Slightly widen the external conductor of the coaxial cable, which is crimped to a contact on the internal conductor, in order to smoothly enter the shell inside the external conductor. Press in the external conductor end of the coaxial cable to just before the crimping part of the shell and put the sleeve into the crimping section.
7-1 7 ME-JJ-01 400mm Branch line Trunk cable 400mm max. Branch line Trunk cable Chapter 7: Wiring Method 7-1 Cable trunk and branch lines On the illustration of the cable wiring below, a bold line means a trunk and the thin lines branched from the trunk with a "T" shape are called branch lines.
7-2 7 (1) Fixing of the cable In order not to put any force on the cable and the JW-21MN, fasten the cable to an line nearby input of a control panel or a "T" branch point to the JW- 21MN using saddles etc.
7-3 7 (6) Bending radius of the signal cable should be less than 45 mm (outside). - Specification of the cable manufacturer is that bending radius should be 6x of the cable finish outside diameter (approx.
7-4 7 7-4 Waterproof and insulation processing of connectors In order to prevent water intrusion into the "T" branch connectors and the straight connectors, we recommend to wind a self-adhesive tape and provide waterproof processing for them.
7-5 7 7-5 Wiring of cables at outside control panels Do not bundle the coaxial cable (the trunk and branch lines) together with power cables, and separate from power cables at least by 100 mm. Do not put the coaxial cable into a power line wired duct.
7-6 7 7-7 Wiring method for adding a communication station (1) Branching method When branching a line for an additional station, be sure to branch from the trunk using a T connector.
7-7 7 (3) Notes When adding a communication station, follow the items below. Item Reason Another branch line from a branch line may not give appropriate communication by reflection wave. The use of the same station number twice may cause communication errors.
8-1 8 Chapter 8: Memory Address on the ME-NET The ME-NET employs a system for addressing individual memory banks in all of the connected equipment by allocating address throughout the ME-NET.
8 8-2 (2) Memory address map (against JW30H) * ME-NET addresses for file 10 to 2C (H) are out of the range the ME-NET specification. These are special addresses for the JW-21MN. - As for address setting range of relay link, register link, and flag of the JW-21MN, see page 11-12 in this manual.
8-3 8 8-2 Memory addresses for computer links - Data memory byte addresses in the computer link must be entered the same way a data link address is entered. - The relay numbers and TMR/CNT numbers are the same for the ME-NET. However the TMR/CNT contact points correspond to the even addresses from 16000 to 17777 (8) .
8 8-4 * ME-NET addresses (SEG10 to 2C) of file 10 to 2C (H) are out of ranges of the ME-NET specification. These are special addresses for the JW-21MN. - Available addresses vary with PC model on which the JW-21MN is installed and its capacity. For details, see an instruction manual for each PC.
9-1 9 - The link relay of the receiving station must be programmed as input signal by the PC program- ming. Also, it may be used as source (S) side of application instruction.
9-2 9 (2) Register link Mainly used for sending and receiving numerical data. [Example] In the case of sending 1 byte data from a master station and slave station 01 and 02.
9-3 9 9-2 Required transmission time and communication delay time [1] Required transmission time This is the time required for the master station to complete communication with all stations, and is determined by the number of connected stations with and the number of data items to transmit.
9-4 9 [2] Communication delay time The communication data on the ME-NET may have the delay shown below. Delay of input module Time required for PC to detect input state (one operation cycle max.) Operation time of sending PC (one operation cycle) Time to complete sending of operation result (one communication cycle max.
9-5 9 [3] Data transmission between master PC and slave PC Providing synchronous transfer gives positive data communication. [An example of synchronized transfer by OUT instruction] - 00000 is turned "ON" at the master station side.(OUT 02000 is a self-holding circuit.
9-6 9 9-3 Expansion of network The JW-21MN can transmit data between 64 stations at maximum. If more than 64 stations are required for data link, you can add communication stations with the procedure below.
9-7 9 Master Slave 01 02 03 04 05 06 07 10 11 12 13 14 15 16 17 20 21 Slave 20 21 22 23 24 25 73 74 .
10-1 10 Chapter: 10 Description for Computer Link Operation When connected to a host computer with a network module that is compatible with the ME-NET specifications, the JW-21MN can transfer data. 10-1 Computer link function The host computer communicates with each station number one by one.
10-2 10 10-2 Basic commands Meaning and available memory address ranges of each command are shown in the table below - Numeric values of each command are command numbers specified by the ME-NET. - Write mode assignment shows write enabled/disabled to the PC memory.
10-3 10 10-3 Optional commands The JW-21MN optional commands are any commands not specified in the ME-NET specifications. These are commands specific to the JW-21MN. The host computer may use these optional commands for communication between JW-21MNs and PCs (JW20/JW20H/JW30H) with a JW-21MN installed.
10-4 10 [1] Read free memory size Read free memory size. [Write mode assignment] : None [Communication format] Command Response Ex. When reading the amount of free program memory (up to 7.
10-5 10 [3] Reading PC mode Read PC's mode. [Write mode assignment] : None [Communication format] Command Response [Ex.] When the PC reads program mode (Data in the cells are hexadecimal notation). Command Response [4] Setting PC mode Set the PC to an assigned mode.
10-6 10 [5] Reading system memory Read the specified number of bytes of data from the specified address in system memory. [Write mode assignment] : None [Communication format] Command Response [Ex.
10-7 10 [7] Reading date Read the year, month, date, and day of week. However, when JW-21CU or JW-31CUH/H1 is used as PC, they do not have clock function and the reading will be meaningless. [Write mode assignment] : None [Communication format] Command Response [Ex.
10-8 10 [9] Reading time Read out time (hour, minute, second) of clock. However, when JW-21CU or JW-31CUH/H1 is used as PC, these PC do not have clock function and the read out data will be unsettled. [Write mode assignment] : None [Communication format] Command Response [Example] Reading a time of 8 : 30 : 30 AM.
10-9 10 [11] Correct clock time Correct the clock setting. However, when a JW-21CU or JW-31CUH/H1 is used as PC, they do not have clock function and the reading will be meaningless. [Write mode assignment] : 1 or 2 [Communication format] Command Response [Ex.
10-10 10 [13] Read the optional parameters Read the parameter data for option module (other than JW-21MN) from the control module. [Write mode assignment] : None [Communication format] Command Response [Ex.] Read the parameters at address 030 to 032 (8) for an option module (No.
10-11 10 [15] Read the special I/O parameters Read out parameter data of special I/O modules (other than JW-21MN) from the control module. [Write mode assignment] : None [Communication format] Command Response [Ex.] To read parameter address data 030 to 032 (8) of the special I/O module (Module No.
10-12 10 [17] Set the secret function: JW30H only Enables the secret function, or deletes previously registered passwords. [Write mode assignment] - When command S = 01 (H) , none. - When command S = 0F (H) , 2 (and when the PC is stopped by using the "PC operation stop F8 (H) command.
10-13 10 [19] Check the secret function: JW30H only Enables/disables the secret function. [Write mode assignment] : None [Communication format] Command Response [Ex.] To determine whether the secret function is enabled (the data in cell are in hexadecimal).
10-14 10 [20] Response on error When a station that has received data encounters an error while processing data after receiving an optional command from the host computer, it will send a response as follows. Response - Symbols other than above "+," "C," "L" and "A" : Same as the description on page 10-3.
11-1 11 Chapter 11: Setting of Switches and Parameter 11-1 Operation procedure -M ake sure to turn "OFF" the power of the PC prior to setting the module No. switch and station number switch after installing the JW-21MN. - Prior to setting the parameters, set the mode of the JW-21MN to "program mode.
11-2 11 [2] Module No. switch (UNIT NO.) Select error history storage registration area and data link (save memory function) area for a slave station by setting the mode switches.
11-3 11 4 3 2 1 0 F E D C B A 9 8 7 6 5 (Factory setting: OFF) ON OFF LT (Rear side) (4) Termination resistance switch (LT) When the JW-21MN is at the termination station of the communication line, make sure to set the termination resistance switch to "ON.
11-4 11 4 3 2 1 0 F E D C B A 9 8 7 6 5 (Factory setting: ON) ON OFF LG (Rear side) (5) Shield ground switch (LG) For communication lines, use a coaxial cable. As coaxial cable is an unbalanced circuit, ground its shield by turning "ON" the shield ground switch.
11-5 11 11-3 Setting contents of master station parameters [1] Setting contents When the JW-21MN is used as a master station, set the following items for parameters.
11-6 11 * Corresponding symbols on pages 11-7 to 11-9 - to are equivalent to number of page 11-13. -P arameter addresses other than above mentioned are reserved areas and prohibited to be changed.
11-7 11 Slave station 01 (8) (Data memory) Master station 00 (8) (Data memory) Register link area (Within a total of 2048 bytes) Relay link area (Within a total of 256 bytes) bytes bytes bytes 24 .
11-8 11 (2) In case that setting the data link (save memory function) when the master station and all slave stations are JW-21MN's. Memory addresses inside control module of slave station continue in order of receiving and sending.
11-9 11 - Set the receiving area for save memory function within the range of the link area. 0 £ a 1 £ Total number of bytes of relay link area - h 1 0 £ a n £ Total number of bytes of relay link .
11-10 11 [Example for setting] The master station and slave station 01 and 02 are JW-21MN. It shows example for setting that slave station 01 is data link (standard function) and slave station 02 is data link (save memory function with 30H mark).
11-11 11 コ 1000 Time limited contact 000000 000377 000400 000677 I / O relay コ 0000 コ 0377 b0000 File address (8) Byte address Relay link area setting range 015000 015777 コ 0400 Auxiliary rela.
11-12 11 (2) When master station PC is JW30H - When master and slave stations are JW-21MN and set to data link (the standard function) : - When slave stations are JW-21MN and set to data link (the save memory function) : *1: When JW-32CUH/H1 is used (JW-32CUH1: 000000 to 177777 or 000000 to 077777).
11-13 11 [4] Setting procedure Set parameters of the master station following the procedure below. [ ] : See page in chapter 11 ① to ⑭ are equivalent to number of page 11-5, and 11-6.
11-14 11 • key: Changeover unit of figures → HEX (hexadecimal) → OCT (octal) → DCM (decimal) → Bit pattern Turn to program mode (stop PC operation). Setting of parameters is only available when the PC is in program mode. Select parameter setting mode.
11-15 11 Lower Upper 00 (H) · In case of standard function, set top address by file address (8) . In case of save memory function, set number of offset bytes. 004004 (8) 004005 (8) 004006 (8) 004007 (8) Lower Upper 00 (H) · 00 (H) : The top address is the same address of the master station regardless of the value set at of 004004 to 004005 (8) .
11-16 11 From the previous page Write 000200 (8) in parameter ad- dresses 004004 to 004005 (8) . Write 000 (8) (=00 (H) ) in parameter address 004006 (8) . Write 00004 (D) (offset 4) in parameter addresses 004010 to 004011 (8) . Write 00 (H) in parameter address 004012 (8) .
11-17 11 From the previous page Set top address of register link area on slave station 01 to 77 (8) (at standard function)/number of offset bytes (at save memory function) Set in parameter addresses 004404 to 004777 (8) . These top addresses should not overlap the resister link area, flag area, or any area used by other option module.
11-18 11 to to From the previous page Set the number of sending bytes of the slave station (01 to 77) relay link [DCM (decimal), word] Set the number of sending bytes in decimal on the parameter addresses 005002 to 005177 (8) . (set in each station, 2 bytes for each station).
11-19 11 Set connection status of slave station [bit pattern, byte] Set "connected slave station as 01 and 02, output error code" in paramenter address 007750 (8) .
11-20 11 Covert to hexadecimal figures Set top address of flag area From the previous page File address: OCT (octal), word File number/flag: HEX (hexadecimal), byte Set the top address of the flag area (24 bytes) in order to monitor the communication condition and PC operation condition on the parameter address 007764 to 007767 (8) .
11-21 11 Writing to the EEPROM of the JW-21MN, start operation [HEX (hexadecimal), byte] From the previous page Write 81 (H) Write "81 (H) " into parameter address 007777 (8) and write the set parameter contents into the EEPROM of the JW-21MN.
11-22 11 11-4 Setting slave station parameters (common for all slave stations) When the JW-21MN is used as a slave station, set the following items for parameters. [1] Setting contents E0 01 00 80 e 1 to e n i 1 to i n Setting item ① V2 Number of receiving bytes of relay link in save memory function Set the number of bytes by decimals.
11-23 11 • When PC is JW30H •W hen PC is JW20/JW20H Flag areas are allocated by 24 bytes from each top address. For setting the top address of flag area, use the file address (8) allocated throughout the memory area and set within the setting range shown below.
11-24 11 [3] Setting procedure [ ] : See page in chapter 11 Whether the station number information should be output or not Set top address of flag area [ 26 ] [ 27 ] [ 28 ] [ 28 ] [ 26 ] [ 26 ] [ 25 ] [ 25 ] [ 25 ] [ 25 ] When not using save memory function ① to ⑤ are equivalent to number of page 11- 22.
11-25 11 Turn to program mode (stop PC operation). Setting of parameters is only available when the PC is in program mode. Select parameter setting mode. Write "00 (H) " to parameter address 007777 (8) and stop operation of the JW-21MN. Setting of the parameter is only available when the operation of the JW-21MN is stopped.
11-26 11 Lower Upper Set the number of sending bytes in decimal on the parameter address 007720 to 007721 (8) . Set the number of sending bytes in decimal on the parameter address 007722 to 007723 (8) .
11-27 11 Covert to hexadecimal figures Set top address of flag area From the previous page File address: OCT (octal), word File number/flag: HEX (hexadecimal), byte Set the top address of the flag area (24 bytes) in order to monitor the communication condition and PC operation condition on the parameter address 007764 to 007767 (8) .
11-28 11 Write 81 (H) Writing to the EEPROM of the JW-21MN, start operation [HEX (hexadecimal), byte] From the previous page Write "81 (H) " into parameter address 007777 (8) and write the set parameter contents into the EEPROM of the JW-21MN.
12-1 12 Chapter 12: Errors and Countermeasures The operating condition of the JW-21MN can be monitored using its indication lamps, flags, and the system memory of a PC. 12-1 Indication lamps LED "1" to "80" indicate error codes when an error occurs.
12-2 12 12-2 Flag Flag area is 24 bytes from the "flag top address" set in the master station/slave station parameters. [1] Flag table [ In case of flag top address is コ 0740 (initial value) ] - Even a slave station can monitor 24 bytes of flag.
12-3 12 [2] In the case of a master station (1) Communication monitor flag This flag is used to monitor the communication condition with other stations. Non-connected station keeps this flag as "OFF." The master station periodically executes communication recovery operation with the communication error slave station.
12-4 12 [3] In the case of slave station 01 to 77 (8) (1) Communication monitor flag This flag is used to monitor the communication condition with other stations.
12-5 12 [4] Monitor operation condition by each station PC By creating a program having the flags shown below in each station's PC, the JW-21MN can monitor the operation condition of each station’s PC.
12-6 12 12-3 Storage of error code When an error occurs in the JW-21MN, it stores the occurred error’s code to system memory #160, #170 and error history storage register of each station's PC. - In some cases, error code 23 (H) or 2A (H) is stored when inputting power.
12-7 12 (1) System memory #170 to 177 (option module error code) The error code stored in the system memory #170 is shifted to #170 to #177 one after the other as new errors occur. Thus, the system memory can store up to 8 errors. When the PC is operating by RAM, these error codes do not disappear even after turning OFF the power.
12-8 12 (4) Error history When the JW-21MN has errors, it stores them in an error history register. The storage area is specified using the module No. switch setting value. The storage area for the error history (128 bytes) is divided into 8 sections (16 bytes each).
13-1 13 Start Turn "OFF" the JW20/JW20H/JW30H's power Remove the cables from the JW-21MN Remove the JW-21MN from the rack panel Set the switches of the new JW-21MN Install the new JW-21MN Connect the cables to the new JW-21MN Turn "ON" the JW20/JW20H/JW30H’s power Load the parameters.
14-1 14 After stopping operation, record the parameters of the JW-21MN onto the memory of the personal computer. (3) Start operation of the JW-21MN After recording the parameters onto the personal computer, start operation of the JW-21MN. Select "Start operation.
14-2 14 <Load> (1) Load to the personal computer Load the contents of the floppy diskette into the memory of the personal computer. Select "FD TRANS." Select "Load." Select a file name. Press the "Enter" key. Start loading into the personal computer.
15-1 15 Chapter 15: Specifications 15-1 General specifications 15-2 Communication specifications Applicable PC Installing slot Storage temperature Ambient temperature Ambient humidity Vibration resist.
15-2 15 15-3 Data link specifications Both standard function and save memory function are available. Select by the mode switch on the JW-21MN. (1) Standard function (2) Save memory function Item Specifications 64 stations max. Relay link : コ 1000 to コ 1477 (Select by the module No.
15-3 15 15-4 Computer link specifications [Outside dimensional drawings] Item Specifications 64 stations max. Maximum 1024 bytes per command According to the host computer command Data memory read/wri.
16-1 16 Chapter 16: Appendix 16-1 Maintenance and check Check wiring, installation, and switch settings. ON Communication cable JW-21MN Not parallel with or proximate to high voltage lines or strong power lines. Branch lines (drop cable) are within 400 mm.
16-2 16 16-2 Recovery method at communication errors (1) Check flow chart First communication? Does the error occur continuously? Recovery See "When the communication error occurs continuously" on page 16- 7. Occurrence of error See "When the communication error occurs instantaneously " on page 16-7.
16-3 16 (2) Check cable/connector As errors on the junction from the main cable to the drop cable or the contact failure on the connecting point of each station or errors of the master module are assumed, check with the following procedure. Error only 1 station Monitor individual communication flag in support tool.
16-4 16 03 (8) Remove the connector on point A, and turn ON the termination resistance of the master station. 07 (8) 06 (8) 05 (8) Master station 04 (8) B D 7 OFF A C Disconnection - If the bus cable between the slave station 05 (8) and 06 (8) is disconnected in the following system.
16-5 16 - When the master station indicates error code 6F (H) and the COMM lamp lights. The cause may be a setting error of any of the slave stations which are set in the parameter. Check the following master station parameters. When slave station is JW-21MN, see "Chapter 11: Setting of Switches and Parameter" for setting range.
16-6 16 When the COMM lamp of the master station is OFF (SD, RD, and CD are flickering). Check the following master station's parameters. Other cases - Check the switches of the JW-21MN (see check item) - Check optional cable of PC (The JW-21MN does not operate normally without an optional cable.
16-7 16 (4) When the communication error occurs instantaneously. Cause may be: - Noise on the communication line. - Fault of a communication module. - Fault of a communication cable. Check the error's timing. When the error occurs synchronous with a peripheral industrial robot's operation, noise to the communication line may be a cause.
16-8 16 16-3 Table of parameter memory (1) Master station The set contents of the parameter addresses 004004 to 004377 (8) and 004404 to 004777 (8) shown below are in the case that a JW-21MN is used for a slave station.
16-9 16 * When 00 (H) is set, the value becomes the same top address of the master station regardless of the setting value of 004404 to 004405 (8) . - Initial value of the address 004400 to 004777 (8) are all 00 (H) .
16-10 16 (3 / 5) - Initial value of the address 005000 to 005177 (8) are all 00 (H) . Address (8) 005000 005001 005002 005003 Set contents When 8 bytes, set to 00008 (D) Setting method (value, example.
16-11 16 - Initial value of the address 005200 to 005377 (8) are all 00 (H) . (4 / 5) Address (8) Set contents 03 (8) (same as 005202 to 005203) 04 (8) (same as 005202 to 005203) 05 (8) (same as 00520.
16-12 16 (5 / 5) - For initial values of above addresses, see page 11-5 and 6. (2) Slave station (01 to 77 (8) ) (1 / 1) - For initial values of above address, see page 11-22.
16-13 16 16-4 Special functions unique to the JW-21MN The functions below are not covered by the ME-NET specifications. They can only be used with PCs which are equipped with a JW-21MN, ME-NET module JW-20MN or ZW-20CM2.
16-14 16 Function < Standard network connection > The operations below using a peripheral device, that is connected to a "n" station, is possible.
16-15 16 - Network setting Select whether the target station for remote programming or remote monitor is on the standard network connection or on the extension network connection. In the case below, 10 to 12 (8) are standard network connections. 01 to 03 (8) are extension network connections.
16-16 16 (2) Parameter setting by remote function This paragraph describes how to set the parameters of other stations' network module (JW-21MN/ JW-20MN) connected on the ME-NET. This is only available when the target station is within the standard network connection.
I-1 I Alphabetical Index [A] Allocation of relay number ........................................................................................ 2-3 Appendix .............................................................................................
I-2 I [M] Maintenance and check .......................................................................................... 16-1 Maintenance ............................................................................................................. 2-3 Memory address for data links .
I-3 I Setting special I/O parameter ............................................................................... 10-11 Setting time ............................................................................................................. 10-8 Shield ground switch .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Sharp JW-21MN è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Sharp JW-21MN - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Sharp JW-21MN imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Sharp JW-21MN ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Sharp JW-21MN, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Sharp JW-21MN.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Sharp JW-21MN. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Sharp JW-21MN insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.