IT
Sharp logo
Manuale d'uso ufficiale

Sharp AE-A18KR

76 pagine·2.4 MB·Climatizzatore·PDF·ENDEFRNLJA
Sharp AE-A18KR
Indice dei contenuti 65 sezioni SPLIT TYPE ROOM AIR CONDITIONER · TÜRKÇE ENGLISH PORTUGUÊS POLSKI ITALIANO EΛΛΗΝΙΚΑ · AY-AP9KR AY-AP12KR · OPERATION MANUAL · … MostraNascondi
SPLIT TYPE ROOM AIR CONDITIONERp.1TÜRKÇE ENGLISH PORTUGUÊS POLSKI ITALIANO EΛΛΗΝΙΚΑp.1AY-AP9KR AY-AP12KRp.1OPERATION MANUALp.1CONDIZIONATORE D'ARIA DA CAMERA TIPO SPLITp.1MANUALE DI ISTRUZIONIp.1AY-AP18KR AY-AP24KRp.1ΑΙΡΚΟΝΤΙΣΙΟΝ ΔΩΜΑΤΙΟΥ ΤΥΠΟΥ SPLITp.1ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣp.1AR CONDICIONADO DE SALA DE DUAS UNIDADESp.1MANUAL DE OPERAÇÃOp.1SPLİT KLİMAp.1KULLANMA KILAVUZUp.1POKOJOWY KLIMATYZATOR TYPU SPLITp.1INSTRUKCJA OBSŁUGIp.1JEDNOSTKA WEWNĘTRZNAp.1JEDNOSTKA ZEWNĘTRZNAp.1AY-AP9KR AE-A9KR AY-AP12KR AE-A12KR AY-AP18KR AE-A18KR AY-AP24KR AE-A24KRp.1A. Information on Disposal for Users (private households)p.2IMPORTANT SAFETY INSTRUCTIONS ENGLISHp.3WARNINGS FOR INSTALLATION/ REMOVAL/REPAIRp.3CONTENTSp.3IMPORTANT SAFETY INSTRUCTIONSp.3CAUTIONS FOR LOCATION/ INSTALLATIONp.3PART NAMESp.4INDOOR UNITp.4OUTDOOR UNITp.4AE-A18KR AE-A24KRp.4REMOTE CONTROLp.51 TRANSMITTERp.52 DISPLAYp.5REMOTE CONTROL DISPLAYp.5: AUTO : HEATp.5: COOL : DRYp.5^ TEMPERATURE AND TIMER COUNT DOWNp.5USING THE REMOTE CONTROLp.6LOADING BATTERIESp.6the remote control. 2 Insert batteries in the compartment,p.6AUXILIARY MODEp.6HOW TO USE THE REMOTE CONTROLp.6AUXp.6BASIC OPERATIONp.71 Press the MODE button to select thep.7AUTO HEAT COOL DRYp.72 Press the ON/OFF button to startp.73 Press the THERMOSTAT button to setp.74 Press the FAN button to set the desiredp.7AUTO SOFT LOW HIGHp.75 To turn off the unit, press the ON/OFFp.7ADJUSTING THE AIR FLOW DIRECTIONp.8VERTICAL AIR FLOW DIRECTIONp.8HORIZONTAL AIR FLOW DIRECTIONp.8COANDA AIRFLOWp.9TURBO OPERATIONp.91 During operation, press the TURBOp.9ONE-HOUR OFF TIMERp.10PLASMACLUSTER OPERATIONp.10CANCELp.10TIMER OPERATIONp.11MAINTENANCEp.12TIPS ON SAVING ENERGYp.12MAKE MOST OF THE TIMER OFF FUNCTIONp.12ADDITIONAL NOTES ON OPERATIONp.13BEFORE CALLING FOR SERVICEp.13OPERATING TEMPERATURE RANGEp.13
Page 1 of the Sharp AE-A18KR user manual — JEDNOSTKA WEWNĘTRZNA
Pagina 1 · clicca per ingrandire
Pagina 1
Sharp AE-A18KR — SPLIT TYPE ROOM AIR CONDITIONER diagram (page 1)
Fig. 1

SPLIT TYPE ROOM AIR CONDITIONER

TÜRKÇE ENGLISH PORTUGUÊS POLSKI ITALIANO EΛΛΗΝΙΚΑ

AY-AP9KR AY-AP12KR

OPERATION MANUAL

CONDIZIONATORE D'ARIA DA CAMERA TIPO SPLIT

MANUALE DI ISTRUZIONI

AY-AP18KR AY-AP24KR

ΑΙΡΚΟΝΤΙΣΙΟΝ ΔΩΜΑΤΙΟΥ ΤΥΠΟΥ SPLIT

ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣ

AR CONDICIONADO DE SALA DE DUAS UNIDADES

MANUAL DE OPERAÇÃO

SPLİT KLİMA

KULLANMA KILAVUZU

POKOJOWY KLIMATYZATOR TYPU SPLIT

INSTRUKCJA OBSŁUGI

INDOOR UNIT UNITÀ INTERNA ΕΣΩΤΕΡΙΚΗ ΣΥΣΚΕΥΗ UNIDADE INTERIOR Ç ÜNİTE

OUTDOOR UNIT UNITÀ ESTERNA ΕΞΩΤΕΡΙΚΗ ΣΥΣΚΕΥΗ UNIDADE EXTERIOR DİŞ ÜNİTE

JEDNOSTKA WEWNĘTRZNA

JEDNOSTKA ZEWNĘTRZNA

AY-AP9KR AE-A9KR AY-AP12KR AE-A12KR AY-AP18KR AE-A18KR AY-AP24KR AE-A24KR

* Plasmacluster is a trademark of SHARP Corporation.

Page 2 of the Sharp AE-A18KR user manual — A. Information on Disposal for Users (private households)
Pagina 2 · clicca per ingrandire
Pagina 2

A. Information on Disposal for Users (private households)

1. In the European Union Attention: If you want to dispose of this equipment, please do not use the ordinary dust bin! Used electrical and electronic equipment must be treated separately and in accordance with legislation that requires proper treatment, recovery and recycling of used electrical and electronic equipment. Following the implementation by member states, private households within the EU states may return their used electrical and electronic equipment to designated collection facilities free of charge*. In some countries* your local retailer may also take back your old product free of charge if you purchase a similar new one. *) Please contact your local authority for further details. If your used electrical or electronic equipment has batteries or accumulators, please dispose of these separately beforehand according to local requirements. By disposing of this product correctly you will help ensure that the waste undergoes the necessary treatment, recovery and recycling and thus prevent potential negative effects on the environment and human health which could otherwise arise due to inappropriate waste handling.

2. In other Countries outside the EU If you wish to discard this product, please contact your local authorities and ask for the correct method of disposal. For Switzerland: Used electrical or electronic equipment can be returned free of charge to the dealer, even if you don’t purchase a new product. Further collection facilities are listed on the homepage of www.swico.ch or www.sens.ch

B. Information on Disposal for Business Users.

1. In the European Union If the product is used for business purposes and you want to discard it: Please contact your SHARP dealer who will inform you about the take-back of the product. You might be charged for the costs arising from take-back and recycling. Small products (and small amounts) might be taken back by your local collection facilities. For Spain: Please contact the established collection system or your local authority for take-back of your used products.
2. In other Countries outside the EU If you wish to discard of this product, please contact your local authorities and ask for the correct method of disposal.

The battery supplied with this product contains traces of Lead. For EU: The crossed-out wheeled bin implies that used batteries should not be put to the general household waste! There is a separate collection system for used batteries, to allow proper treatment and recycling in accordance with legislation. Please contact your local authority for details on the collection and recycling schemes. For Switzerland: The used battery is to be returned to the selling point. For other non-EU countries: Please contact your local authority for correct method of disposal of the used battery. Pb

Page 3 of the Sharp AE-A18KR user manual — Indice dei contenuti
Pagina 3 · Indice
Indice

Indice

SPLIT TYPE ROOM AIR CONDITIONERp.1TÜRKÇE ENGLISH PORTUGUÊS POLSKI ITALIANO EΛΛΗΝΙΚΑp.1AY-AP9KR AY-AP12KRp.1OPERATION MANUALp.1CONDIZIONATORE D'ARIA DA CAMERA TIPO SPLITp.1MANUALE DI ISTRUZIONIp.1AY-AP18KR AY-AP24KRp.1ΑΙΡΚΟΝΤΙΣΙΟΝ ΔΩΜΑΤΙΟΥ ΤΥΠΟΥ SPLITp.1ΕΓΧΕΙΡΙΔΙΟ ΛΕΙΤΟΥΡΓΙΑΣp.1AR CONDICIONADO DE SALA DE DUAS UNIDADESp.1MANUAL DE OPERAÇÃOp.1SPLİT KLİMAp.1KULLANMA KILAVUZUp.1POKOJOWY KLIMATYZATOR TYPU SPLITp.1INSTRUKCJA OBSŁUGIp.1JEDNOSTKA WEWNĘTRZNAp.1JEDNOSTKA ZEWNĘTRZNAp.1AY-AP9KR AE-A9KR AY-AP12KR AE-A12KR AY-AP18KR AE-A18KR AY-AP24KR AE-A24KRp.1A. Information on Disposal for Users (private households)p.2IMPORTANT SAFETY INSTRUCTIONS ENGLISHp.3WARNINGS FOR INSTALLATION/ REMOVAL/REPAIRp.3CONTENTSp.3IMPORTANT SAFETY INSTRUCTIONSp.3CAUTIONS FOR LOCATION/ INSTALLATIONp.3PART NAMESp.4INDOOR UNITp.4OUTDOOR UNITp.4AE-A18KR AE-A24KRp.4REMOTE CONTROLp.51 TRANSMITTERp.52 DISPLAYp.5REMOTE CONTROL DISPLAYp.5: AUTO : HEATp.5: COOL : DRYp.5^ TEMPERATURE AND TIMER COUNT DOWNp.5USING THE REMOTE CONTROLp.6LOADING BATTERIESp.6the remote control. 2 Insert batteries in the compartment,p.6AUXILIARY MODEp.6HOW TO USE THE REMOTE CONTROLp.6AUXp.6BASIC OPERATIONp.71 Press the MODE button to select thep.7AUTO HEAT COOL DRYp.72 Press the ON/OFF button to startp.73 Press the THERMOSTAT button to setp.74 Press the FAN button to set the desiredp.7AUTO SOFT LOW HIGHp.75 To turn off the unit, press the ON/OFFp.7ADJUSTING THE AIR FLOW DIRECTIONp.8VERTICAL AIR FLOW DIRECTIONp.8HORIZONTAL AIR FLOW DIRECTIONp.8COANDA AIRFLOWp.9TURBO OPERATIONp.91 During operation, press the TURBOp.9ONE-HOUR OFF TIMERp.10PLASMACLUSTER OPERATIONp.10CANCELp.10TIMER OPERATIONp.11MAINTENANCEp.12TIPS ON SAVING ENERGYp.12MAKE MOST OF THE TIMER OFF FUNCTIONp.12ADDITIONAL NOTES ON OPERATIONp.13BEFORE CALLING FOR SERVICEp.13OPERATING TEMPERATURE RANGEp.13
Page 4 of the Sharp AE-A18KR user manual — OUTDOOR UNIT
Pagina 4 · clicca per ingrandire
Pagina 4

PART NAMES

INDOOR UNIT

Sharp AE-A18KR — INDOOR UNIT diagram (page 4)
Fig. 2

6 Power Supply Cord

7 Vertical Adjustment Louvre

8 Horizontal Adjustment Louvre

q OPERATION Lamp (red )

w TIMER Lamp (orange )

e TURBO Lamp (green )

OUTDOOR UNIT

AE-A18KR AE-A24KR

Sharp AE-A18KR — OUTDOOR UNIT diagram (page 4)
Fig. 3

t Refrigerant Tube and Interconnecting

Show 15 more labels / short text on this page
1 Inlet (Air) · 2 Open Panel · 3 Air Filter · 4 AUX Button · 5 Receiver Window · 9 Outlet (Air) · 0 PLASMACLUSTER Lamp(blue) · r · r Inlet (Air) · t · Cord · y · y Drainage Hose · u Outlet (Air) · u
Page 5 of the Sharp AE-A18KR user manual — ^ TEMPERATURE AND TIMER COUNT DOWN
Pagina 5 · clicca per ingrandire
Pagina 5

REMOTE CONTROL

1 TRANSMITTER

Sharp AE-A18KR — REMOTE CONTROL diagram (page 5)
Fig. 4

2 DISPLAY

7 ONE-HOUR OFF TIMER Button

5 6 7 8 9 0 q w e r t y

9 TIMER ON Button

q TIMER OFF Button

e TIMER CANCEL Button

y COANDA AIRFLOW Button

REMOTE CONTROL DISPLAY

: AUTO : HEAT

: COOL : DRY

$ FAN SPEED Symbols

: AUTO : Manual setting

% COANDA AIRFLOW Symbol

^ TEMPERATURE AND TIMER COUNT DOWN

* TIMER ON / TIMER OFF Indicator

Show 22 more labels / short text on this page
3 ON/OFF Button · 4 THERMOSTAT Button · 5 DISPLAY Button · 6 PLASMACLUSTER Button · 8 MODE Button · 0 FAN Button · w SWING Button · r TURBO Button · t RESET Button · % · ! MODE Symbols · ! · ^ · @ · # · @ TURBO Symbol · $ · & · # PLASMACLUSTER Symbol · * · Indicator · & TRANSMITTING Symbol
Page 6 of the Sharp AE-A18KR user manual — AUX
Pagina 6 · clicca per ingrandire
Pagina 6

USING THE REMOTE CONTROL

LOADING BATTERIES

  • CAUTION:
  • Do not allow the signal receiver window to receive strong direct sunlight, since it can adversely affect its operation. If the signal receiver window is exposed to direct sunlight, close a curtain to block the light.
  • Using a fl uorescent lamp with a quick starter in the same room may interfere with transmission of the signal.
  • The unit can be affected by signals transmitted from the remote control of a television, VCR or other equipment used in the same room.
  • Do not leave the remote control in direct sunlight or near a heater. Also, protect the unit and remote control from moisture and shock which can discolour or damage them.

Use two size-AAA (R03) batteries. 1 Remove the battery cover at the back of

the remote control. 2 Insert batteries in the compartment,

making sure the ± and — polarities are correctly aligned. 3 Reinstall the battery cover. 4 Press the RESET button using a thin

stick.

Sharp AE-A18KR — the remote control. 2 Insert batteries in the compartment, diagram (page 6)
Fig. 5 · the remote control. 2 Insert batteries in the compar…
  • NOTE:
  • The battery life is approximately one year in normal use.
  • When you replace the batteries, always change both batteries, and make sure they are the same type.
  • If the remote control does not operate properly after replacing the batteries, press the RESET button using a thin stick.
  • If you will not be using the unit for a long time, remove the batteries from the remote control.

AUXILIARY MODE

Use this mode when the remote control is not available.

  • TO TURN ON Lift the open panel of the indoor unit and press the AUX button.
  • The red OPERATION lamp ( ) on the unit will light and the unit will start operating in the AUTO mode.
  • The fan speed and temperature setting are set to AUTO.

HOW TO USE THE REMOTE CONTROL

  • Point the remote control towards the unit’s signal receiver window and press the desired button. The unit generates a beep when it receives the signal.
  • Make sure there is no curtain or other object between the remote control and the unit.
  • The remote control can send signals from up to 7 metres away.

TO TURN OFF Press the AUX button again. • The red OPERATION lamp ( ) on the unit will turn off.

AUX

Sharp AE-A18KR — AUX diagram (page 6)
Fig. 6
Page 7 of the Sharp AE-A18KR user manual — 5 To turn off the unit, press the ON/OFF
Pagina 7 · clicca per ingrandire
Pagina 7

BASIC OPERATION

1 Press the MODE button to select the

Sharp AE-A18KR — BASIC OPERATION diagram (page 7)
Fig. 7

operation mode.

AUTO HEAT COOL DRY

2 5 3 1 4

2 Press the ON/OFF button to start

operation. • The red OPERATION lamp ( ) on the unit will light.

3 Press the THERMOSTAT button to set

the desired temperature.

AUTO/DRY MODE • The temperature can be changed up to 2°C above or below the temperature automatically determined by the air conditioner.

Sharp AE-A18KR — 3 Press the THERMOSTAT button to set diagram (page 7)
Fig. 8 · 3 Press the THERMOSTAT button to set

COOL/HEAT MODE • The temperature can be set within the range of 18 to 32°C.

Sharp AE-A18KR — 3 Press the THERMOSTAT button to set diagram (page 7)
Fig. 9 · 3 Press the THERMOSTAT button to set

4 Press the FAN button to set the desired

In the AUTO mode, the temperature setting and mode are automatically selected accord- ing to the room temperature when the unit is turned on.

fan speed.

AUTO SOFT LOW HIGH

Room temp. at operation start-upAutomatic Operation Mode Temperature Setting Temperature Setting Below 21˚CHEAT23˚C 21˚C-24˚CDRYRoom Temp. - 2˚C 24˚C-26˚CCOOL24˚C 26˚C-28˚CCOOL25˚C Above 28˚CCOOL26˚C
  • In the DRY mode, the fan speed is preset to AUTO and cannot be changed.

5 To turn off the unit, press the ON/OFF

button again. • The red OPERATION lamp ( ) on the unit will turn off.

Page 8 of the Sharp AE-A18KR user manual — AY-AP18KR AY-AP24KR
Pagina 8 · clicca per ingrandire
Pagina 8

ADJUSTING THE AIR FLOW DIRECTION

VERTICAL AIR FLOW DIRECTION

HORIZONTAL AIR FLOW DIRECTION

Sharp AE-A18KR — VERTICAL AIR FLOW DIRECTION diagram (page 8)
Fig. 10

Adjust the horizontal air fl ow direction with the louver lever.

  • The vertical adjustment louvre will swing continuously. 2 Press the SWING button again when the

AY-AP18KR AY-AP24KR

AY-AP9KR AY-AP12KR

Sharp AE-A18KR — AY-AP18KR AY-AP24KR diagram (page 8)
Fig. 11
  • CAUTION: Never attempt to adjust the vertical adjustment louvre manually.
  • Manual adjustment of the vertical adjustment louvre can cause the unit to malfunction.
  • When the vertical adjustment louvre is positioned at the lowest position in the COOL or DRY mode for an extended period of time, condensation may result. Do not adjust the horizontal adjustment louvres to the extreme left or right in the COOL mode with the fan speed set to “SOFT ( )” for an extended period of time. Condensation may form on the louvres.

Louvre lever

Page 9 of the Sharp AE-A18KR user manual — 1 During operation, press the TURBO
Pagina 9 · clicca per ingrandire
Pagina 9

COANDA AIRFLOW

TURBO OPERATION

In cooling or dry operation, vertical adjustment louver is set obliquely upward to deliver cool air to the ceiling in order to avoid direct airfl ow. In heating operation, vertical adjustment louver is set downward to deliver the warm air down to the fl oor. 1 During operation, press the COANDA

In this operation, the air conditioner fan works at "extra high" speed with a setting temperature of 15°C in COOL and DRY modes and 32°C in HEAT mode to rapidly cool or heat the room.

1 During operation, press the TURBO

AIRFLOW button.

  • button.
  • The remote control will display “ ” .
  • The temperature display will go off.
  • The green TURBO lamp ( ) on the unit will light up.
  • The remote control will display “ ”.
Sharp AE-A18KR — 1 During operation, press the TURBO diagram (page 9)
Fig. 12 · 1 During operation, press the TURBO
Sharp AE-A18KR — 1 During operation, press the TURBO diagram (page 9)
Fig. 13 · 1 During operation, press the TURBO

TO CANCEL Press the COANDA AIRFLOW button again.

TO CANCEL Press the TURBO button again. • The green TURBO lamp ( ) on the unit will turn off.

  • NOTE:
  • You can not set the temperature or fan speed during the TURBO operation.
  • To turn off the TURBO lamp, press the DISPLAY button.
  • After the unit has run for 30 minutes in TURBO operation, the fan setting will become the "HIGH" speed, and temperature setting will become 18°C in COOL and DRY modes.
Page 10 of the Sharp AE-A18KR user manual — CANCEL
Pagina 10 · clicca per ingrandire
Pagina 10

ONE-HOUR OFF TIMER

PLASMACLUSTER OPERATION

Plasmacluster ions released into the room will reduce some airborne mold. 1 During operation, press the

When the ONE-HOUR OFF TIMER is set, the unit will automatically turn off after one hour. 1 Press the ONE-HOUR OFF TIMER

  • PLASMACLUSTER button.
  • The remote control will display “ ”.
  • The blue PLASMACLUSTER lamp on the unit will light up.
  • button.
  • The remote control will displays “ ”.
  • The orange TIMER lamp ( ) on the unit will light up.
  • The unit will stop operating after one hour.
Sharp AE-A18KR — PLASMACLUSTER OPERATION diagram (page 10)
Fig. 14
Sharp AE-A18KR — PLASMACLUSTER OPERATION diagram (page 10)
Fig. 15

CANCEL

TO CANCEL Press the PLASMACLUSTER button again. • The PLASMACLUSTER lamp on the unit will turn off.

TO CANCEL Press the CANCEL button. • The orange TIMER lamp ( ) on the unit will turn off.

Alternatively, turn the unit off by pressing the ON/OFF button. • The red OPERATION lamp ( ) and the orange TIMER lamp ( ) on the unit will turn off.

  • NOTE:
  • Use of the PLASMACLUSTER operation will be memorized, and it will be activated the next time you turn on the air conditioner.
  • To turn off the PLASMACLUSTER lamp, press the DISPLAY button.
  • To perform Plasmacluster operation in FAN only mode, press the PLASMACLUSTER button when the unit is not operating. The mode symbol of the remote control will go off and the fan speed can not be set AUTO.
  • NOTE:
  • The ONE-HOUR OFF TIMER operation has priority over TIMER ON and TIMER OFF operations.
  • If the ONE-HOUR OFF TIMER is set while the unit is not operating, the unit starts one-hour operation at the formerly set condition.
  • If you wish to operate the unit for another hour before the ONE-HOUR OFF TIMER is activated, press the ONE-HOUR OFF TIMER button again during operation.
Page 11 of the Sharp AE-A18KR user manual — TIMER OPERATION
Pagina 11 · clicca per ingrandire
Pagina 11

TIMER OPERATION

TIMER OFF 1 Press the TIMER OFF ( ) button and set the time as desired.

TIMER ON 1 Press the TIMER ON ( ) button and set the time as desired.

  • The time setting will change as you press the button as follows. Hold the button down to speed through the settings.
  • The time setting will change as you press the button as follows. Hold the button down to speed through the setting.

0.5h 1.0h 1.5h 10h 11h 12h 0.5h 1.0h 1.5h 10h 11h 12h

  • The orange TIMER lamp ( ) on the unit will light.
  • The time setting will count down to show the remaining time.
  • The orange TIMER lamp ( ) on the unit will light.
  • The time setting will count down to show the remaining time.
Sharp AE-A18KR — TIMER OPERATION diagram (page 11)
Fig. 16
Sharp AE-A18KR — TIMER OPERATION diagram (page 11)
Fig. 17

Select the mode, temperature and fan speed setting as desired.

  • When the temperature is set with the TIMER ON, the temperature will show in the display for 5 seconds and then return to the time display.
  • The unit will turn on prior to the set time to allow the room to reach the desired temperature by the programmed time. (Awaking function)

TO CANCEL Press the CANCEL button. • The orange TIMER lamp ( ) on the unit will turn off.

TO CANCEL Press the CANCEL button. • The orange TIMER lamp ( ) on the unit will turn off.

  • NOTE:
  • Timer duration can be set from a minimum half an hour to a maximum of 12 hours. Up to 9.5 hours, you can set in half-hour increments, and from 10 to 12 hours, in 1-hour increments.
  • The latest time setting will be memorized and will appear on the remote control display the next time you set the TIMER OFF or TIMER ON.
  • The TIMER OFF and TIMER ON can not be set together.
  • While ONE-HOUR OFF TIMER is set, the TIMER OFF and TIMER ON setting are unavailable.
  • If the ONE-HOUR OFF TIMER is set while the TIMER OFF or TIMER ON is activated, the TIMER ON or TIMER OFF setting will be cancelled.

COOL/DRY MODE: • One hour after the time operation begins, the temperature setting rises 1°C higher than the original temperature setting.

HEAT MODE: • One hour after the timer operation begins, the temperature setting drops 3°C lower than the original temperature setting.

Page 12 of the Sharp AE-A18KR user manual — MAKE MOST OF THE TIMER OFF FUNCTION
Pagina 12 · clicca per ingrandire
Pagina 12

MAINTENANCE

TIPS ON SAVING ENERGY

Be sure to disconnect the power cord from the wall outlet or turn off the circuit breaker before performing any maintenance.

Below are some simple ways to save energy when you use your air conditioner.

  • SET THE CORRECT TEMPERATURE
  • Setting the thermostat 1°C higher than the desired temperature in the COOL mode and 2°C lower in the HEAT mode will save approximately 10 percent in power consumption.
  • Setting the temperature lower than necessary during cooling operation will result in increased power consumption.

CLEANING THE FILTERS 1 Turn off the unit. 2 Remove the fi lters. 1 Lift the open panel. 2 Push the air fi lters up slightly to unlock them. 3 Pull the air fi lters down to remove them.

  • BLOCK DIRECT SUNLIGHT AND PREVENT DRAFTS
  • Blocking direct sunlight during cooling operation will reduce power consumption.
  • Close the windows and doors during cooling and heating operations.

SET PROPER AIR FLOW DIRECTION TO OBTAIN THE BEST AIR CIRCULATION

3 Clean the fi lters.

Use a vacuum cleaner to remove dust. If the fi lters are dirty, wash them with warm water and a mild detergent. Dry fi lters in the shade before reinstalling. 4 Reinstall the fi lters. 1 Reinstall the fi lters in the original positions. 2 Close the open panel.

KEEP FILTER CLEAN TO ENSURE THE MOST EFFICIENT OPERATION

MAKE MOST OF THE TIMER OFF FUNCTION

DISCONNECT THE POWER CORD WHEN THE UNIT IS NOT USED FOR AN EXTENDED PERIOD OF TIME • The indoor unit still consumes a small amount of power when it is not operating.

  • CLEANING THE UNIT AND THE REMOTE CONTROL
  • Wipe them with a soft cloth.
  • Do not directly splash or pour water on them. It can cause electrical shock or equipment damage.
  • Do not use hot water, thinner, abrasive powders or strong solvents.

MAINTENANCE AFTER AIR CONDITIONER SEASON 1 Operate the unit in the COOL mode,

temperature setting 32˚C, for about half a day to allow the mechanism to thoroughly dry. 2 Stop the operation and unplug the unit.

Turn off the circuit breaker, if you have one exclusively for the air conditioner. 3 Clean the fi lters, then reinstall them.

MAINTENANCE BEFORE AIR CONDITIONER SEASON 1 Make sure that the air fi lters are not dirty. 2 Make sure that nothing obstructs the air

inlet or outlet.

Page 13 of the Sharp AE-A18KR user manual — BEFORE CALLING FOR SERVICE
Pagina 13 · clicca per ingrandire
Pagina 13

ADDITIONAL NOTES ON OPERATION

BEFORE CALLING FOR SERVICE

OPERATING TEMPERATURE RANGE

CRACKING NOISE The unit may produce a cracking noise. This sound is generated by the friction of the front panel and other components expanding or connecting due to a temperature change.

INDOOR TEMP. OUTDOOR TEMP.

COOLING upper limit 32˚C 46˚C lower limit 21˚C 21˚C

HEATING upper limit 27˚C 24˚C lower limit – –7˚C

A LOW BUZZING NOISE EMITTED This is a sound emitted when the unit is generating Plasmacluster ions.

  • The built-in protective device may prevent the unit from operating when used out of this range.
  • Condensation may form on the air outlet if the unit operates continuously in the COOL or DRY mode when humidity is over 80 percent.

SWISHING NOISE The soft, swishing noise is the sound of the refrigerant fl owing inside the unit.

  • WATER VAPOUR
  • In the COOL and DRY operation, water vapour can sometimes be seen at the air outlet due to the difference between the room air temperature and the air discharged by the unit.
  • In the HEAT operation, water vapour may fl ow out of the outdoor unit during de-icing.

WHEN POWER FAILURE OCCURS This air conditioner has a memory function to store settings when a power failure occurs. After power recovery, the unit will automatically re- start in the same settings which were active before the power failure, except for timer settings. If the timers were set before a power failure, they will need to be re-set after power recovery.

ODOR EMITTED FROM THE PLASMACLUSTER AIR OUTLET This is the smell of ozone generated from the Plasmacluster Ion generator. The ozone concentration is very small, posing no adverse effect on your health. The ozone discharged into the air rapidly decomposes, and its density in the room will not increase.

PREHEATING FUNCTION In the HEAT operation, the indoor fan may not start for two to fi ve minutes after the unit is turned on to prevent cold air from blowing out of the unit.

  • DE-ICING FUNCTION
  • When ice forms on the heat exchanger in the outdoor unit during the HEAT operation, an automatic de-icer provides heat for about 5 to 10 minutes to remove the ice. During de-icing, the inside and outside fans stop operating.
  • After de-icing is completed, the unit automatically resumes operation in the HEAT mode.

If the unit appears to be malfunctioning, check the following points before calling for service.

IF THE UNIT FAILS TO OPERATE Check to see if the circuit breaker has tripped or the fuse has blown.

  • IF THE UNIT FAILS TO COOL (OR HEAT) THE ROOM EFFECTIVELY
  • Check the fi lters. If dirty, clean them.
  • Check the outdoor unit to make sure nothing is blocking the air inlet or outlet.
  • Check the thermostat is proper setting.
  • Make sure windows and doors are closed tightly.
  • A large number of people in the room can prevent the unit from achieving the desired temperature.
  • Check whether any heat-generating appliances are operating in the room.
  • HEATING EFFICIENCY
  • The unit employs a heat pump that draws heat from the outside air and releases it into the room. The outside air temperature therefore greatly affects the heating effi ciency.
  • If the heating effi ciency is reduced due to low outside temperatures, use an additional heater.
  • It takes time to warm up and heat the entire room because of the forced air circulation system.
  • IF THE UNIT FAILS TO RECEIVE THE REMOTE CONTROL SIGNAL
  • Check whether the remote control batteries have become old and weak.
  • Try to send the signal again with the remote control pointed properly towards the unit’s signal receiver window.
  • Check whether the remote control batteries are installed with the polarities properly aligned.

BEFORE CALLING FOR SERVICE

The following conditions do not denote equip- ment malfunctions

UNIT DOES NOT OPERATE The unit will not operate if it is turned on immediately after it is turned off. The unit will not operate immediately after the mode is changed. This is to protect the internal mechanisms. Wait 3 minutes before operating the unit.

Please call for service when OPERATION lamp, TIMER lamp and/or PLASMACLUSTER lamp on the unit blink.

UNIT DOES NOT SEND OUT WARM AIR The unit is preheating or de-icing.

ODORS Carpet and furniture odors that entered into the unit may be sent out from the unit.

Fonti

Riferimenti e link

Pagine di riferimento in questo manuale: produttore, supporto e download.

Fai una domanda su Sharp AE-A18KR

I possessori del prodotto e il nostro team di solito rispondono entro 24 ore, e la tua domanda sarà utile anche ad altri.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nessuna domanda ancora per il dispositivo Sharp AE-A18KR

Invia la prima domanda: risponderanno altri possessori o il nostro team.

Documento originale

Sharp AE-A18KR manuale in PDF

76 pagine·2.4 MB·Climatizzatore·PDF
Clicca su qualsiasi pagina in alto per aprirla qui
Pagina 1 / …
100%
Caricamento pagine…