1 Dometic Corporation 13128 S tate Rt 226, P .O. Box 38 Big Prairie, Ohio 4461 1-0038 USA SeaLand Product Hotline 1-800-321-9886 (8:00 a.m. - 5:00 p.m.
2 TABLE OF CONTENTS W ARNING: When using this product, always exercise basic safety precautions including the following: • Read all instructions before use or installation. • Never connect this product to any electrical circuit other than the specified voltage, and never exceed the amperage draw specified in “Electrical Wiring” on page 3.
3 Electrical Wiring It is imperative that adequate wire size and proper over-current protection (fuse or circuit breaker) sizes are used. The following chart can be used as a guideline. Refer to chart on page 10 for solenoid/relay information. 12 VDC 24 VDC 32 VDC 1 15 V AC (1 phase) 230 V AC (1 phase) 6 to 8 ga.
4 4. Disconnect electrical source to motor , following lock-out/t ag-out procedure. 5. Remove the six (6) 5/16" fasteners around the circumference of the pump top. 6. Carefully remove the pump top from the pump body . 7. Turn the pump top upside down to expose the diaphragm and rod bolt.
5 3. Install and adjust first hex nut for proper bushing clearance of 0.020" [.50mm]. 4. Hold adjustment nut from turning and install and tighten the lock nut. 5. Recheck bushing clearance. IMPORT ANT : INADEQUA TE CLEARANCE OR LOOSE LOCK NUT WILL CAUSE THE ECCENTRIC T O BIND, RESUL TING IN PUMP ST ALLING AND PREMA TURE BUSHING WEAR.
6 G . MOTOR REPLACEMENT T o Remove: 1. Turn off electrical power to pump. 2. Remove access plate from wiring junction box on motor . 3. Unhook wiring from motor leads. 4. Remove the four (4) motor mounting bolts securing the motor to the speed (gear) reducer .
7 TROUBLESHOOTING W ARNING Before attempting to open or service the pump: 1. If possible, flush pump with clean water and disinfectant. 2. Allow motor to cool if overheated. 3. Disconnect power supply to pump before servicing unit. Follow proper lock-out/tag-out procedures.
8 DIMENSIONALSPECIFICA TIONS WIRING DIAGRAMS M-Series V acuum Pump Wiring Schematic (V acuFlush System) NOTE : V acuum t ank pressure switches are wired in parallel for multiple toilet inst allations.
9 PARTS LIST 1 2 3 4 5 6 7 8 9 10 11 12 13 310537 310538 342812 342813 342814 342815 342816 342817 342818 341792 342820 342821 342822 342823 341797 340704 Seal and Gasket Kit Bearing and Race Kit Inpu.
10 12VDC SOLENOID 24VDC SOLENOID 32VDC SOLENOID 1 15V AC RELA Y 50/60 HZ 220V AC RELA Y 50/60 HZ 345831 346900 346530 341431 342478 345831 346900 346530 342479 342478 Parts Below Not Shown 1/2HP 3/4HP.
11 PARTS LIST 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 342469 341598 342422 342466 342770 342454 340689 640286 340720 342413 342472 342759 342.
12 MANUF ACTURER’S ONE-YEAR LIMITED WARRANTY SeaLand warrants to the original purchaser only , that this product, if used for personal, family or household purposes, is free from defects in material and workmanship for a period of one year from the date of purchase.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il SeaLand Vacuum Pump è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del SeaLand Vacuum Pump - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso SeaLand Vacuum Pump imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul SeaLand Vacuum Pump ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il SeaLand Vacuum Pump, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del SeaLand Vacuum Pump.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il SeaLand Vacuum Pump. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo SeaLand Vacuum Pump insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.