Manuale d’uso / di manutenzione del prodotto FM200 del fabbricante Sea-Fire
Vai alla pagina of 14
FM200 ® MODEL FT FIRE EXTINGUISHERS INST ALLA TION INSTRUCTIONS OWNER’S MANUAL THIS MANUAL IS AN INTEGRAL P AR T OF THE SYSTEM AND AS SUCH, THE EXTINGUISHER MUST BE INST ALLED AND MAINT AINED ACCORDINGL Y . READ AND COMPL Y WITH THESE INSTRUCTIONS, W ARNINGS AND LIMIT A TIONS BEFORE INST ALLING.
W ARNING CONCENTRA TED AGENT AND BY-PRODUCT OF APPLICA TION TO FIRE ARE T OXIC. A VOID BREA THING OF FUMES OR PROLONGED EXPOSURE. ACCIDENT AL DIS- CHARGE MA Y OCCUR DURING HANDLING OR INST ALLA TION OF THIS DEVICE, READ AND COMPL Y WITH INSTRUCTIONS, WARNINGS, AND LIMIT A TIONS CONT AINED IN THIS MANUAL.
REMINDER: Sea-Fire systems shall be considered as supplementary to the number of portable fire extinguishers required on-board and are designed and intended for enclosed unoccupied compartment installations that are not subject to direct weather or water .
OTHER APPLICA TIONS • Engine Compartments (maximum 150 cubic feet) • Bow Thrusters • Small Generator Set Enclosures • Consoles • Electrical Enclosures • Flammable Liquid Storage Areas • Pump Enclosures • Alternative Fuel Storage Areas In case of a fire and system discharged, the electrical supply to the motor must be discon- nected.
Figure 5 Step 8 Secure the detection tubing to the bulkhead by using the clips and screws supplied. Nylon wire ties may be used in lieu of the clips and screws.
Figure 6 THE FT EXTINGUISHER INST ALLA TION IS COMPLETE. INDICA TOR LIGHT OPERA TION All Sea-Fire extinguishers approved for marine applications are packaged with an indicator light and escutcheon. ‘‘The U.S. Coast Guard approval requires an indicator light if this unit is installed for the protection of a boat’s engine compartment.
ELECTRICAL SWITCH INDICA TOR LIGHT GROUND IN-LINE FUSE IGNITION IGNITION SWITCH ST ARTER BA TTERY Figure 9 Figure 3 WHILE MAKING ELECTRICAL CONNECTION CAN RESUL T IN INJUR Y FROM FIRE OR ELECTRICAL BURNS. The indicator light is rated for 12 VDC (contact factory for other voltages).
Before operating the protected vessel, visually inspect pressure gauge for compliance and ensure the supervisory (indicator) light is lit. If gauge reads low in pressure, and or the indica- tor light is extinguished, remove, and replace the system immediately .
CONDITIONS All Sea-Fire products are tested after manufacture and shipped in perfect working order . Damage noted upon receipt of shipment should be addressed as a shipping claim, the filing of which is the sole responsibility of the consignee for which the total compensatory award will be limited to that appropriated by the carrier .
ALL FT (STINGER) MODELS ARE APPROVED FOR VERTICAL MOUNTING ONL Y . INTENDED OPERA TING TEMPERA TURE RANGE : 32°F –130°F (0°C – 54°C ) ST ANDARD EQUIPMENT LIST SUPPLIED WITH EACH SYSTEM 1. ONE TUBING KIT , P ART # 130-121 – 10 FOOT TUBE OR 130-122 – 15 FOOT TUBE.
FG/FD/FT/MD/R/C-MODEL Fire Extinguisher MSDS No. SF002 MA TERIAL SAFETY DA T A SHEET Section 1 — Company and Chemical Identification MET ALCRAFT/SEA-FIRE MARINE EMERGENCY PHONE: 1-800-535-5053 9331-A PHILADELPHIA ROAD PHONE: 1-800-445-7680 BAL TIMORE, MARYLAND 21237DA TE: NOVEMBER 10, 2005 http://www .
Section 7 — Handling and Storage Handle, transport and store carefully and securely to avoid accidental knocking over or other severe physical impacts.
Section 15 — Regulatory Information U.S. Federal Regulations: The components of this product are either on the TSCA Inventory or exempt (i.e. impurities, a polymer complying with the exemption rule at 40 CFR 723.
SEA-FIRE MARINE SEA-FIRE EUROPE L TD Division of Metalcraft Inc. Unit 7. io Centre. Stephenson Road 9331-A Philadelphia Road Fareham, Hampshire Baltimore, Maryland 21237 USA PO15 5RU, United Kingdom Website: www .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Sea-Fire FM200 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Sea-Fire FM200 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Sea-Fire FM200 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Sea-Fire FM200 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Sea-Fire FM200, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Sea-Fire FM200.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Sea-Fire FM200. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Sea-Fire FM200 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.