Manuale d’uso / di manutenzione del prodotto ECOi del fabbricante Sanyo
Vai alla pagina of 32
ECOi TM V ariable R efrigerant Flo w (VRF), Multi-Zone, Heat P ump & Heat R eco v er y S y stems.
INTRODUCTION.. ..................................................2 ECOi™ Building Y our Business..................................3 ECOi™ . Y our Building Life T ool ..................................4 SANY O OUTDOOR Units ........................
INTRODUCTION E CO i™ . B u i l d i ng Y o u r B u s i n e s s . SANY O's Brand V ision SANYO HV AC consistently builds new ideas to help build your business. By delivering multi-zone options, space-saving and environmentally friendly designs, our solutions are evolving, improving solutions.
Contractors. Buil ding Support. At SANYO, we realize contractors are looking for turnkey installation and support. ECOi™ is quite simply the perfect building solution. With its modular design and ease of installation, it’ s a solution that can grow with any building project.
INTRODUCTION For th e b ui ldi ngs re qui ri ng sim ult ane ou s h eat ing an d coo lin g, SANYO 3-Way ECOi™ system provides the perfect solution 05 05 C o m m e r ci a l o f f i c e b u i l d i n g.
MODELS (T ype: Nominal Cooling Capacity , etc) V olt PH CHDZ 07263 72,000 BTU Heat Recovery 208-230V/60 HZ 3 CHDZ R07263 72,000 BTU Heat Recovery W ith Salt Protection - Special Order 208-230V/60 HZ 3.
SANY O OUTDOOR 07 DESCRIPTION CHDZ (R) 07263 CHDZ (R) 09663 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW 72,000 5.3 81,000 5.79 96,000 7.75 108,000 8.6 ELECTRICAL RA TINGS VOL T AG E R A TING COOLING RUNNING AMPERES HEA TING RUNNING AMPERES MIN.
WCHDZ 14463 / WCHDZ 16863 / WCHDZ 19263 WCHDZ 21663 / WCHDZ 24063 WCHDZ 26463 / WCHDZ 28863 K E Y F E AT U R E S : * T hre e -Way H ea t Re c ov er y * Co mbin e 3 ou td oor u nit s up t o 24 tons * .
SANY O OUTDOOR 09 WCHDZ SERIES 3-W ay ECOi VRF Heat Recov ery Combined Units DESCRIPTION WCHDZ 14463 WCHDZ 16863 WCHDZ 19263 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW includes (1) CHDZ07263 and (1) CHDZ07263 144,000 10.
WCHDZ SERIES 3-W ay ECOi VRF Heat Recov ery combined units DESCRIPTION WCHDZ 21663 WCHDZ 24063 WCHDZ 26463 WCHDZ 28863 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW includes (3) CHDZ07263 216,000 15.
11 SANYO’ s Mini ECOi is suited for numerous commercial and premium residential applications. SANY O OUTDOOR CHX SERIES Mini ECOi Multi Split VRF Heat Pump CHX (R) 03652 / CHX (R) 05252 K E Y F E AT.
12 CHDX SERIES 2-W ay ECOi VRF Heat Pump DESCRIPTION (T ype: Nominal Cooling Capacity , etc) V olt PH CHDX 07263 * 72,000 BTU Heat Pump 208-230V/60 HZ 3 CHDX (R) 07263 * 72,000 BTU Heat Pump W ith Sal.
13 SANY O OUTDOOR CHDX SERIES 2- W ay ECOi VRF Heat Pump * NOTE : *460 V olt Step Down T ransformers (460-230) available for 6 and 8 ton condensers (R) indicates with salt protection - Special Order DESCRIPTION CHDX (R) 07263 CHDX (R) 09663 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW 72,000 5.
14 WCHDX SERIES W 2-W ay ECOi VRF Heat Pumps combined units WCHDX 14463 / WCHDX 16863 / WCHDX 19263 WCHDX 21663 / WCHDX 24063 WCHDX 26463 / WCHDX 28863 K E Y F E AT U RE S : * He at P um p * Co mbin e.
15 SANY O OUTDOOR WCHDX SERIES W 2-W ay ECOi VRF Heat Pumps combined units DESCRIPTION WCHDX 14463 WCHDX 16863 WCHDX 19263 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW includes (2) CHDX07263 144,000 10.
16 WCHDX SERIES W 2-W ay ECOi VRF Heat Pumps combined units DESCRIPTION WCHDX 21663 WCHDX 24063 WCHDX 26463 WCHDX 28863 PERFORMANCE COOLING CAP ACITY : BTU/H POWER INPUT : KW HEA TING CAPACITY : BTU/H POWER INPUT : KW includes (3) CHDX07263 216,000 15.
17 SANY O INDOOR KHX 0752 / KHX 0952 / KHX 1252 / KHX 1862 KHX 1962 / KHX 2452 / A TK-SVRK56BA K E Y F E AT U RE S : * “EC O F rie ndl y” R 41 0A R ef r iger an t * 20 8/ 23 0 V , 1 Ph ase, 6 0 H .
18 THX SERIES Ceiling Suspended Unit DESCRIPTION THX 1252 THX 1852 THX 2452 CAP ACIT Y COOLING HEA TING 12,000 BTU 14,000 BTU 19,000 BTU 21,000 BTU 25,000 BTU 27,000 BTU CUR REN T COOLING HEA TING 0.14/0.17 A 0.14/0.15 A 0.15/0.14 A 0.15/0.17 A 0.34/0.
SYSTEM/MODEL Components (T ype: Nominal Cooling Capacity , etc) V olt PH 07 AHX 52 System 7500 BTU 1-Way Ceiling cassette (includes grille) 208-230V/60 HZ 1 AHX 0752 cassette 208-230V/60 HZ 1 PNR-AH12.
XMHX SERIES Concealed Ducted - Low Profile, Low Static, with Condensate Pump 4-W ay Ceiling Cassette 24" x 24", with Condensate Pump 12 XMHX 52 / 18 XMHX 52 K E Y F E AT U RE S : * “EC O .
SANY O INDOOR XHX SERIES 4-W ay Ceiling Cassette 35" x 35", with Condensate Pump 24 XHX 52 / 36 XHX 52 K E Y F E AT U RE S : * “EC O F rie ndl y” R 41 0A R ef r iger an t * 20 8/ 23 0 V .
UMHX SERIES Concealed Ducted - Low Profile, Low Static, with Condensate Pump UMHX 0762 / UMHX 0962 / UMHX 1262 UMHX 1562 / UMHX 1862 K E Y F E AT U RE S : * “E C O Fr ie nd ly ” R 410A R e f ri g.
SANY O INDOOR UHX SERIES Concealed Ducted - Medium Static DESCRIPTION UHX 0762 UHX 0962 UHX 1262 UHX 1562 UHX 1862 UHX 2462 UHX 3662 UHX 4862 UHX 5462 PERFORMANCE COOL ING CAP A CITY HEA TING CAP ACIT.
DHX SERIES Concealed Ducted - Medium-High Static DESCRIPTION DHX 3652 DHX 4852 CAP ACIT Y COOLING HEA TING 36,000 BTU 39,000 BTU 47,800 BTU 54,600 BTU CUR REN T COOLING HEA TING 2.84/2.89 A 2.74/2.80 A 3.24/3.19 A 3.17/3.42 A POW ER INP UT COOLING HEA TING 548/620 W 528/602 W 644/695 W 627/756 W UNIT DIMENSIONS Inches (") / lbs.
SANY O INDOOR FHX/FMHX SERIES Floor Mounted FMHX 0762 / FMHX 0962 / FMHX 1262 FMHX 1562 / FMHX 1862 / FMHX 2462 K E Y F E AT U RE S : * “EC O F rie ndl y” R 41 0A R ef r iger an t * 20 8/ 23 0 V ,.
CONTROL S Y S TEMS SANYO’ s system control network is the heart and soul of the ECOi™ unit, enabling it to live with the living inside. With a simple two-wire loop installation, we put co nt rol in yo ur ha nds , l ite ral ly .
SANY O Control S ystem 27 CONTROL S Y S TEMS Simple System Control Network WIRED REMO TES SIMPLE TO INST ALL K E Y F E AT U RE S : ( S I M PL E RE M O T E ) * T hin and E as y T o Re ad * Simple T o I.
CONTROL S Y S TEMS Simple System Control Network SHA-K T 2 5 6BA Intel l igent Controll er K E Y F E AT U RE S ( INT EL L IGENT CONT ROL) : * 6.5 Inc h T ouch Scr een P anel * Co ntr ols up to 2 5 6 I.
SANY O Control S ystem 29 CONTROL S Y S TEMS Building Management Integration K E Y F E AT U RE S : * Co mmunica te W it h L onWork s Co mp atible Sy st ems * St ar t / St op * Co ntr ols Up T o 1 6 Groups ( Ma ximum 6 4 In door U nits ) * F o r 17 o r m or e g r o u p s o f in d o or u ni t s c on n e c t a d di t i o n a l inter fac e unit s.
30 A CCESSORIES P ART NUMBER DESCRIPTION 2-W a y Distr ibution Kits (cut to fit) Simple System Control Network APR -P160UK DISTRIBUTION JOINT KIT CUT TO FIT Used with 2 Pipe indoor Unit Piping - Up t.
31 SERVICES SER VICES Simple System Control Network P ART NUMBER DESCRIPTION ECO -SC-4 ECOi COMMISSIONING (Per normal business day , up to 24 tons) IC -SC-1 COMMISSIONING OF INTELLIGENT CONTROLLER (Ba.
Us age ○ T h e a i r c on d i t i o n e r s l i s t e d h e r e i n a r e o nl y f o r c o o l i n g / h e a t i n g a r e a s u s e d b y peo pl e. D o no t u se t h e un i t f or f oo ds , an ima ls , pla n t s, p r e ci si on m ac hi ne s, w o r k s o f a r t o r o t h e r o b j e c t s .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Sanyo ECOi è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Sanyo ECOi - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Sanyo ECOi imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Sanyo ECOi ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Sanyo ECOi, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Sanyo ECOi.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Sanyo ECOi. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Sanyo ECOi insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.