Manuale d’uso / di manutenzione del prodotto Indoor Fireplace del fabbricante Avalon Stoves
Vai alla pagina of 40
• Masonry Fireplace • Factory Built (Metal) Fireplace • Mobile Home Approved Tested and Listed by Omni-Test Laboratories, Inc. Portland, Oregon Report # 028–S–51-2 ASTME-1509 1995, ULCC 1482 Astoria Bay™ Pellet Insert - - Please read this entire manual before installation and use of this pellet fuel-burning room heater.
2 Introduction Travis Industries 4 0 5 0 5 2 5 1 00-01144 Introduction We welcome you as a new owner of a Astoria Bay pellet heater. In purchasing a Astoria Bay you have joined the growing ranks of concerned individuals whose selection of an energy system reflects both a concern for the environment and aesthetics.
Table of Contents 3 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Introduction Introduction ......................................................2 Important Information .........................................2 Safety Precautions Safety Precautions ...
4 Safety Precautions Travis Industries 4 0 5 0 5 2 5 1 00-01144 • Do not operate the heater if you smell smoke coming from the heater. Turn the P OWER switch to "OFF", monitor your heater, and call your dealer.
Safety Precautions 5 Travis Industries 4 0 5 0 5 2 5 1 00-01144 • The heater will not operate during a power outage. If a power outage does occur, check the heater for smoke spillage and open a window if any smoke spills into the room. • This heater must be connected to a standard 115 V.
6 Specifications Travis Industries 4 0 5 0 5 2 5 1 00-01144 Heating Specifications: Approximate Maximum Heating Capacity (in square feet)* ........................................ 800 to 2,250 Burn Rate (Pounds per Hour)** ............................
Installation 7 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Before You Begin READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE THIS HEATER. FAILURE TO FOLLOW THE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.
8 Installation Travis Industries 4 0 5 0 5 2 5 1 00-01144 Hopper Extension Set-up This pellet heater has a variable-height hopper. This allows the hopper to be lowered for smaller fireplaces. Follow the instructions below to set the correct hopper extension position.
Installation 9 Travis Industries 4 0 5 0 5 2 5 1 00-01144 • Remove the correct knock-outs in the hopper walls following the directions below. Use a center-punch (or other suitable tool) to remove the appropriate knock- outs in the hopper walls (punch the holes out from the inside).
10 Installation Travis Industries 4 0 5 0 5 2 5 1 00-01144 Clearances • Insert must be placed so that no combustibles are within, or can swing within (e.g. drapes, doors), 36" of the front of the heater. • Insert must be placed a minimum 8-3/4" from a side wall (or combustible protruding more than 3/4").
Installation 11 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Venting the Pellet Stove • INSTALL VENT AT CLEARANCES SPECIFIED BY THE VENT MANUFACTURER). • DO NOT CONNECT THE PELLET VENT TO A VENT SERVING ANY OTHER APPLIANCE OR STOVE. • DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.
12 Installation Travis Industries 4 0 5 0 5 2 5 1 00-01144 Mobile Home Requirements • Outside air is required (used for combustion) - see the directions below. WARNING: D O NOT INSTALL IN SLEEPING ROOM. CAUTION: THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED.
Installation 13 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Baffle Installation Install the baffles included with the insert (see page 28 for details). Restrictor Adjustment The restrictor is used to adjust airflow to the firepot. It should be adjusted to match the heat output setting and burn the pellets at the appropriate rate.
14 Installation Travis Industries 4 0 5 0 5 2 5 1 00-01144 Surround Panel & Circuit Board Installation NOTE : Attach the vent prior to installing the surround panels (& circuit board). a Remove the circuit board from the rear hopper support. Disconnect the wiring harness from the circuit board (see step “ d ” below for a detailed view).
Installation 15 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Installation into a Masonry Fireplace “ L ” Vent Flex Section Outside air may be drawn from the ash cleanout. “ L ” Vent Storm Collar Vertical Cap Cover Plate (non-combustible) Silicone Seal the cover plate with silicone.
16 Installation Travis Industries 4 0 5 0 5 2 5 1 00-01144 Installation into a Factory Built (Metal) Fireplace “ L ” Vent Flex Section HINT: Paint the interior of the fireplace with latex paint to prevent fireplace odors from entering the home.
Operation 17 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Safety Notice • Read this entire manual (especially the "Safety Precautions" on pages 4 and 5) before using this heater. Failure to follow the instructions may result in property damage, bodily injury, or even death.
18 Operation Travis Industries 4 0 5 0 5 2 5 1 00-01144 Loading Pellets Lift the hopper lid to its vertical position. Pour pellets into the hopper until full. NOTE: The hopper holds approximately 48 to 88 pounds of pellets (depending upon hopper set-up).
Operation 19 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Manual Mode Manual mode requires the user to turn the heater on and off manually. To Start Press the "Manual Start" button. That's it. The stove automatically goes to a medium burn rate and high fan while the igniter starts the fire burning within 10 minutes.
20 Operation Travis Industries 4 0 5 0 5 2 5 1 00-01144 Auto Mode Auto mode allows you to use a thermostat to control room temperature. The stove automatically turns on when the temperature drops below the thermostat setting. Once the stove reaches operating temperature, the stove then runs at the heat output setting selected.
Operation 21 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Restrictor Adjustment The restrictor is used to adjust airflow to the firepot. It should be adjusted to match the heat output setting and burn the pellets at the appropriate rate. This keeps the firepot as clean as possible.
22 Operation Travis Industries 4 0 5 0 5 2 5 1 00-01144 Start-Up Sequence This stove utilizes a start-up sequence whenever the mode switch is changed or the heater is started when cold. This is to ensure proper operation through all possible settings and operational states (hot or cold, pellets burning or not burning, etc.
Operation 23 Travis Industries 4 0 5 0 5 2 5 1 00-01144 "MANUAL AUGER" Button This button turns the auger on. It is used to “ prime ” the auger after the hopper has run out of pellets.
24 Maintenance Travis Industries 4 0 5 0 5 2 5 1 00-01144 Daily Maintenance (whenever using the heater) Inspect the Burn When burning on high, the flames should be bright orange with embers jumping from the firepot. NOTE : the optimal restrictor position will vary over time as soot builds up inside the exhaust system.
Maintenance 25 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Daily Maintenance (whenever using the heater) - Continued Check Firepot for Clinkers If the flames seem to be coming only from the sides, or are orange/black, turn the heater off and check for clinkers.
26 Maintenance Travis Industries 4 0 5 0 5 2 5 1 00-01144 Daily Maintenance (whenever using the heater) - Continued Opening The Door Swing open this panel to access the door latch (use the tool if necessary). Phillips Screwdriver When securing the door, make sure the pawl fits over the bracket before tightening.
Maintenance 27 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Weekly Maintenance (or every 5 bags of pellets) Flyash Removal This heater was designed to allow for easy flyash removal with the included tools. However, to ease maintenance, several pellet stove owners have purchased vacuums specifically made to remove flyash.
28 Maintenance Travis Industries 4 0 5 0 5 2 5 1 00-01144 Weekly Maintenance (or every 5 bags of pellets) - Continued Check Baffles, Ashbox, Ashpan, Dispose Ash If Necessary Removing the Ashpan The ashpan slides out from under the firebox. NOTE : When replacing the ash pan make sure it is pushed all the way in.
Maintenance 29 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Weekly Maintenance (or every 5 bags of pellets) - Continued Sweep Ash Into Ashpan HINT: The more often you clean out the flyash, the more efficient your heater will burn. NOTE: Remove the ashbox prior to conducting the service below.
30 Maintenance Travis Industries 4 0 5 0 5 2 5 1 00-01144 Yearly Maintenance (or every ton) WARNING: Disconnect the power cord prior to conducting service.
Maintenance 31 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Yearly Maintenance (or every ton) - Continued Clean the Exhaust Blower (make sure the heater is cool and unplugged) a Remove the surround panels and access the left side of the heater. Remove the shroud covering the blower motor.
32 Maintenance Travis Industries 4 0 5 0 5 2 5 1 00-01144 Yearly Maintenance (or every ton) - Continued Door Seal ! Air leaks into the firebox will decrease the stove's performance greatly, leading to excessive sooting, inefficient burning, and perhaps a malfunction.
Maintenance 33 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Yearly Maintenance (or every ton) - Continued Adjusting the Door Hinge and Latch • The door hinge and door latches may be adjusted to pull the door closer to the body. The illustration below details how to adjust these components.
34 Maintenance Travis Industries 4 0 5 0 5 2 5 1 00-01144 Yearly Maintenance (or every ton) - Continued Check for Air Leaks Around the Door, Glass, and Ashpan ! Air leaks into the firebox will decrease the stove's performance greatly, leading to excessive sooting, inefficient burning, and perhaps a malfunction.
Normal Operating Sounds 35 Travis Industries 4 0 5 0 5 2 5 1 00-01144 Auger Motor When feeding pellets, you may hear the intermittent buzz of this motor running. Covection Fan The modern high efficiency fan may produce a low hum, particularly on "HIGH".
36 Safety Label Travis Industries 4 0 5 0 5 2 5 1 00-01144 Minimum Clearance to Combustible Materials (Measured from insert top) Adjacent Sidewall A 8.
Limited 7 Year Warranty 37 Travis Industries 4 0 5 0 5 2 5 1 00-01144 To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclosed warranty card and mail it within ten (10) days of the appliance purchase date to: TRAVIS INDUSTRIES, INC.
38 Optional Equipment Travis Industries 4 0 5 0 5 2 5 1 00-01144 Thermostat (Part # 99300650) ! Do not connect 120 VAC to the thermostat circuit of this heater (do not use a household thermostat used for a wall-board or other electical heater). 1 Attach the thermostat wire to the circuit board (see the illustration to the right).
Optional Equipment 39 Travis Industries 4 0 5 0 5 2 5 1 00-01144 ZC Kit (99200149) The optional zc kit allows this insert to be directly into the framing of a house or mobile home.
40 Index Travis Industries 4 0 5 0 5 2 5 1 00-01144 Adjusting the Fan Speed ......................................2 1 Air Leaks ..........................................................3 2 Ashpan (Opening and Disposing Ashes) .................2 8 AUGER ON Light .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Avalon Stoves Indoor Fireplace è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Avalon Stoves Indoor Fireplace - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Avalon Stoves Indoor Fireplace imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Avalon Stoves Indoor Fireplace ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Avalon Stoves Indoor Fireplace, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Avalon Stoves Indoor Fireplace.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Avalon Stoves Indoor Fireplace. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Avalon Stoves Indoor Fireplace insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.