Manuale d’uso / di manutenzione del prodotto HS3802ECH62HE del fabbricante Renesas
Vai alla pagina of 27
2003.12.19 H8/3802 Group FP-64E User System Interface Cable for E6000 Emulator User’s Manual H8/3802 HS3802ECH62HE Renesas Microcom puter Development Envi ronment System H8 Famil y/H8/300L Super Low Power Series Rev.
Cautions Keep safety first in your circ uit designs ! 1. Renesas Technology Corp. put s the maxi mum effort into maki ng semiconduct or product s better and more reliable, but the re is always the possi bility that trouble may occur with them. Trouble with semi conductors may lead to personal injury, fi re or propert y damage.
I IMPORTANT INFORMATION READ FIRST • READ this user's manual before using this u ser system interface cable. • KEEP the user's manual handy for future reference. Do not atte mpt to use the user syste m interface ca ble until you fully under stand its mec h an is m.
II LIMITED WARRANTY Renesas warrants its user system interface cabl es to be manufactured in accordance with published specifications and free from defects in material and/or workmanship. Renesas will re pair or replace any user system interfac e cables determine d to be defective in ma terial and/or workmanship.
III State Law: Some states do not allo w the exclusion or li mitation of implied warranties or liability for incidental o r consequen tial damages, so t he above limitation o r exclus io n may no t ap ply to you. This warr ant y give s yo u spec if ic lega l rig hts, and you ma y have other rig hts wh ic h may va ry fro m state to state.
IV SAFETY PAGE READ FIRST • READ this user's manual before using this u ser system interface cable. • KEEP the user's manual handy for future reference. Do not atte mpt to use the user syste m interface ca ble until you fully under stand its mec h an is m.
V W ARNING Observe the pr ecautions listed below. Failur e to do so will result in a FIRE HA ZARD and will damag e the user system and the emula tor product or will resu lt in PERSONAL INJURY. Th e USER PROGRAM will be LOST. 1. Do not repair or remodel the emulator product b y yourself for e lectric sho ck prevention and quality assurance.
i Preface Thank y ou for pu rchasing this u ser sy stem interface cable (HS3802ECH62H) f or the Ren esas’s origin al m icrocom puter H8/3802, H8/ 38004 group.
ii Contents Section 1 Configuration .................................................................................... 1 Section 2 Connection Procedures ...................................................................... 3 2.1 Connectin g User Sy stem Interf ace Cable to Em ulator Station .
1 Section 1 Configuration CAUTION Use an IC149-064- 175-B51 socket (manuf actured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-64E package IC socket on th e user system. Figu re 1 show s the con figuration of the HS3802EC H62H user sy stem interf ace cable for the FP-64E package.
2 Table 1 lists t he HS3802ECH62H com pon ents. Pleas e mak e sure y ou h ave all of these compon ents w hen un packing. Table 1 HS3802ECH62H Com ponen ts No.
3 Section 2 Connection Procedures 2.1 Conn ecting User System Interf ace Cable to Emulator Stati on W ARNING Observe the precautions listed below. Failure t o do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY.
4 Emulator station Cable body connector User system interface cable E6000 Figure 2 Connecting User System Interface Cable to Em ulator Station.
5 2.2 Conn ecting User System Interf ace Cable to User System W ARNING Always switch OFF the user syst em and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part . Before connecting, make sure that pin 1 on bot h sides are correctly aligned.
6 2.2.3 I nserting Cab le Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for an FP-64E pack age on the u ser system w ith pin 1 on the user system interf ace cable head, and insert th e user sy stem in terface cable head into th e IC socket on the user sy stem, as sh own in figu re 3.
7 Fasten the us er system interface cable h ead to the IC socket f or an FP-64E package on the user system with the four screws (M2 x 12 m m ; w ith fou r flat w ashers ) provided. Each screw sh ould be tighten ed a little at a time, alternatin g betw een screw s on oppos ing corners.
8 2.2.5 Fastening Cable B ody Connect the cable body t o the cable head. Cable body Cable head Remove jig Push the remove jig User system Removing Figure 4 Fastening Cable Body.
9 2.3 Recom mende d Dime nsions for User Syst em M ount Pad Figure 5 show s the recom m ended dim ensions f or the mou nt pad (footprint) f or the user sy stem w ith an IC socket f or an FP-64E pack age (IC149- 064-175-B51: man ufactu red by YA MAIC HI ELECTRONICS C o.
10 2.4 Dimension s for User S ystem Interface Cable Head The dimens ions for the u ser sy stem interf ace cable head are show n in figure 6. Unit: mm Tolerance: ±0.
11 2.5 Resul ting Dimension s after Conn ecting User System Interface Cab le The resulting dim ensions, af ter connecting the user sy stem in terface cable head to the u ser system , are show n in f igure 7. Cable head User system Unit: mm Tolerance: ±0.
12 Section 3 Installing the MCU to the User System CAUTION 1. Check the locat ion of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head.
13 MCU Pin 1 IC socket (IC149-064-175-B51 manufactured by YAMAICHI ELECTRONICS Co., Ltd.) User system Screws (M2 x 6 mm) with flat washers Socket cover Figure 8 Installing M CU to User System.
14 Section 4 Verifying Operation 1. When u sing the H8/3802 g roup E6000 em ulator (HS3800EPI60H), t urn on t he em ulator according to th e procedures described in th e H8/3802 Group E6000 Em ulator User' s Manu al (HS3800EPI60HE).
15 Figure 9 sho ws th e system clock oscillator o n the user system interface cable an d the subclock input specificat ions. R2 270 R1 1 M HCU04 HCU04 To E6000 emulator OSC1 OSC2 System clock oscillator Ω Ω 4.0 V 19 ns max. 19 ns max. 4.0 V 1.35 V 0 V 5.
16 Section 5 Notice 1. Make sure that pin 1 on the us er system IC socket is correctly aligned w ith pin 1 on the cable head before insertin g the cable head in to the user sy stem IC socket. 2. The dimens ions of the recom m ended m ount pad for th e user sy stem IC sock et are differen t from those of the MC U.
H8/3802 Group FP-64E User System Interface Cable For E6000 Emulator User's Manual Publication Date: Rev.3.00, December 19, 2003 Published by: Sales Strategic Planning Div. Renesas Technology Corp. Edited by: Technical Documentation & Information Department Renesas Kodaira Semiconductor Co.
H8/3 802 Grou p FP-64 E User Sy stem Inte rface C able for E600 0 Emul ator User’s Ma nual REJ10B0099-0300H.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Renesas HS3802ECH62HE è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Renesas HS3802ECH62HE - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Renesas HS3802ECH62HE imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Renesas HS3802ECH62HE ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Renesas HS3802ECH62HE, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Renesas HS3802ECH62HE.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Renesas HS3802ECH62HE. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Renesas HS3802ECH62HE insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.