Manuale d’uso / di manutenzione del prodotto 494 del fabbricante Remington Power Tools
Vai alla pagina of 24
® A N I N D E P E N D E N T L A B O R A T O R Y T E S T I N G F O R P U B L I C S A F E T Y G 028 Read this manual and all labels carefully before operating your powder actuated tool. This manual should always accompany the tool and be transferred with it upon change of ownership.
2 101437 Maximum 3" (76 mm) * Not provided with tool Power Load* Trigger Muzzle/Guide Recommended Approved Goggles* Power Fastener* Spall Shield Barrel Assembly REMINGT ON Model 494 Powder Actuat.
3 101437 W arning: Safety Precautions The following pages contain detailed warnings, cautions, and rules of safe operation. Read carefully and become familiar before operating to avoid serious injury.
4 101437 482-12 G 018 G 018 G 018 Safety Precautions 5. ALWAYS make sure the work area is clean from loose material and debris. 2. NEVER place your finger on the trigger until the tool’s muzzle is against the work surface. 1. NEVER place your hand over the muzzle.
5 101437 482-19 482-24 G 018 G 018 G 018 G 018 Safety Precautions 3. ALWAYS store UNLOADED powder actuated tool and power loads in a locked container. Keep power loads of different power levels in separate containers. 4 . NEVER carry or pass a loaded powder actuated tool.
6 101437 TOO HARD Point flattens 482-29 ? ? ? 482-25 TOO BRITTLE Surface shatters 482-30 TOO SOFT Sinks in with average hammer blow 482-28 G 018 G 018 G 018 G 018 Safety Precautions 1. ALWAYS know the thickness and type of base material into which you are fastening.
7 101437 CAST IRON GLASS TILE BRICK 482-33 Safety Precautions 3. NEVER make fastenings in spalled or cracked areas. 2 . NEVER attempt to drive power fasteners into very hard or brittle materials including, but not limited to cast iron, glass, tile, stone, brick, or hardened steel.
8 101437 TOO THIN WELD 482-40 G 018 G 018 Safety Precautions 7. DO NOT drive power fasteners into steel base material less then 3/16" thick, within 2" of a weld, within 1/2" of the edge or within 1" of another power fastener.
9 101437 POWER LOADS POWER LOADS 482-49 GASOLINE GAS OLINE 482-50 G 018 G 018 G 018 G 018 Safety Precautions 2. Should the tool fail to fire, hold the muzzle firmly against the work surface for 30 seconds. Release the trigger and remove pressure on the tool while holding the muzzle against the work surface.
10 101437 482-58 YELLOW? BROWN? GREEN? GRAY? G 018 2. Remington power loads are available in four power levels with gray (1) being the lowest power level and yellow (4) being the highest power level. Always start with the lowest power level (gray-level 1) and increase until a proper fastening is made (see page 13 Selecting Fasteners and Loads).
11 101437 482-59 G 018 Safety Precautions 6. Power fasteners are a permanently installed fixture. An act of demolition is required for their removal. Appropriate safety precautions must be taken. Plastic Flute Shank Head 482-60 7. NEVER use common nails or other materials as fasteners.
12 101437 WHY A POWER FASTENER HOLDS IN CONCRETE The compression bond of the concrete to the power fastener accounts for the majority of the holding power. The fastener dis- places the concrete which tries to return to its original form causing a squeezing effect.
13 101437 FASTENING INTO CONCRETE The proper power fastener length can be determined by adding the thickness of the material to be fastened and the amount of fastener that will actually penetrate the concrete. The concrete must be three times as thick as the intended fastener penetration.
14 101437 Operation 1. Grasp muzzle and slide barrel forward rapidly until it stops. This sets piston into firing position and opens the chamber. 4. Push barrel into housing to the closed position. 3. Select the proper Remington Power Load and insert into the chamber until it stops (see Application Chart on page 23).
15 101437 WATER Operation 5. Place the muzzle of tool perpendicular to work surface without tilting the tool. Push tool against work surface until sliding action of barrel stops. 8. Should the tool fail to fire, hold the muzzle firmly against the work surface for 30 seconds.
16 101437 Tang Tang Spring Tang Cap Buffer Muzzle Cap Piston Barrel Receiver Maintenance T roubleshooting Guide PROBLEM Piston rod hangs out of muzzle cap. Overdriving of power fastener. Piston jammed. Expended power load will not extract. Reduction or loss of power.
17 101437 T roubleshooting Guide (cont.) PROBLEM Tool does not completely depress. Tool does not fire. Opening and closing of barrel or pushing down of the tool, etc. is not smooth but is rough or binds. REMEDY Remove breech and check all parts for correct fit assembly.
18 101437 Parts List – Model 494 KEY PART NO. NO. DESCRIPTION QTY. 1 101123-01 Screw, 1/4"-20 x 1.25 2 2 101122-01 Washer 2 3 101128-01 Handle & Trigger Assembly 1 4 056217 Firing Pin Sprin.
19 101437 Accessories DISASSEMBLY 1. a) Remove tang cap, tang spring, and tang. Slide barrel assembly from receiver. b) Remove muzzle cap from barrel by un- screwing counterclockwise. Barrel Assembly Muzzle Cap Barrel Tang Tang Spring Tang Cap Receiver Receiver Screws Firing Pin Spring Handle and Trigger Assembly Firing Pin Sear Spring Sear 2.
20 101437 T ool Disassembly and Assembly WARNING: Always unload a powder actuated tool before disassembling, replacing barrel, cleaning, or assembling. ! WARNING ICON G 001 ASSEMBLY 1. Place buffer, small end first, in muzzle cap. Push piston all the way into the barrel.
21 101437 Buffer and Piston Replacement ! WARNING ICON G 001 WARNING: Always unload a powder actuated tool before disassembling, replacing barrel, cleaning, or assembling. Breech Receiver Barrel Assembly Slot in Barrel Tang Cap Tang Spring Tang 3. Reinsert barrel assembly slotted side down into receiver.
22 101437 482-81a Two by fours Furring strips Metal electrical junction boxes Conduit clips Shelf brackets 1/4" Plywood or pegboard For fastening this Power load and power fastener application information.
23 101437 Application Chart IMPORTANT • If power fastener goes below the top surface of the board, use penetrating control disc (* see illustration below). • Always wear approved eye and ear protection. 482-90 * Use power fastener with penetration control disc, part number 015549.
Limited W arranty Agreement DESA International warrants the Remington Model 494 Powder Actuated Fastening Tool against defects in materials and workmanship for a period of one (1) year from the date of purchase.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Remington Power Tools 494 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Remington Power Tools 494 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Remington Power Tools 494 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Remington Power Tools 494 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Remington Power Tools 494, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Remington Power Tools 494.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Remington Power Tools 494. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Remington Power Tools 494 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.