SHOWER HANDBOOK IMPORTANT: Please retain this booklet for future reference.
CONTENTS Page How to use your shower …………… 2 How your shower works …………… 3 What to do if things go wrong …………… 5 Installation instructions ………….... 6 How to maintain your shower …………… 10 Guarantee …………… 12 How to use your shower 1.
Model 620 - Press button “C”. Th e electricity to the elements is then switched off, water will continue to flow for approximately 5 seconds before switching off. This reduces the temperature of the water in the unit. Switch the electricity off at the ceiling switch or local isolator.
throughout the year from 5 to 20 ° C. This means that in Wi nter, the flow rate will be less than in the Summer to achieve the same outlet temperature. In summer the ‘MED (medium)’ or ‘LOW’ power setti ng may give adequate hot water. The heaters are only switched on when sufficient water is flowing.
Check the spray plate is then free to rotate to give the three settings. In some winter conditions, when the incoming mains water is particularly cold it may be necessary to select the inner or outer spra y pattern only.
a) Water too HOT Water flow restricted by blockage in filter of solenoid valve. Switch o ff water and undo plastic nut on elbow, loosen br ass nut to swing elbow away from solenoid.
c) The handset must not be able to come into contact with any used water in the bath or basin. If it can, even after the hose has been retained by the hose retainer (see diagram 13) , then a vacuum breaker must be fitted.
1. It is recommended that a WRAS (Water Regul ations Advisory Scheme) listed isolating valve is fitted between the rising main and the unit. This will allow the unit to be serviced or exchanged without having to turn off t he water at the mains stop valve.
You may be able to use 6mm² cable if Method 1 (clipped direct) is used. Remember to up-rate the cable if it runs in thermal insulation in a loft, or for a longer distance. 3. A means for disconnection in all poles must be incorporated in the fixed wiring in accordance with the wiring rules.
d) That the holes in the sp ray plate are not blocked. e) Water flow can be adjusted by knob B. 9. DEMONSTRATE OPERATION TO USER 10. LEAVE THESE INSTRUCTIONS WITH THE USER FOR FUTURE REFERENCE. How to maintain your shower It is recommended that the shower unit, riser rail, hose etc.
Diagram 13 11.
Full details of terms and conditions are available on request from: - APPLIED ENERGY PRODUCTS LTD. MORLEY WAY, PETERBOROUGH. PE2 9JJ. Tel +44 (0)1733 456789 Fax: +44 (0) 1733 310606 Website: www.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Redring 620 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Redring 620 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Redring 620 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Redring 620 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Redring 620, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Redring 620.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Redring 620. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Redring 620 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.