crown head II ™ ELECTRIC MARINE TOILET OPERATION, MAINTENANCE, and INSTALLATION INSTRUCTIONS Manufactured after June 2002 THE FOLLOWING ARE CAUTIONARY STATEMENTS THAT MUST BE READ AND FOLLOWED DURING BOTH INSTALLATION AND OPERATION. WARNING: Raritan Engineering Company, Inc.
• Push Button Switch (#164000) Press and hold switch until all waste is cleared from bowl. NOTE: Push Button Switch flushing is shown. Refer to manuals included with Toilet Control (TC12W), Raritime Solid State Timer with Solenoid (#RTC), or Flush Control (#SWF100) for operation Instructions.
MAINTENANCE Cleaning Instructions IMPORTANT: Do not use cleaners that contain ammonia, ethyl acetate, phosphoric acid or concentrated chlorine bleach. These will cause damage to the toilet. Using C.P. (#1PCP22), a bio-enzymatic toilet bowl cleaner (available from Raritan Engineering), will keep the bowl clean and fresh smelling.
WINTERIZING IMPORTANT • Improper winter lay up is a major cause of marine toilet failure. • Use only nontoxic antifreeze. • Flush toilet several times to clear waste from system. • Dispose of all antifreeze in accordance with local and federal regulations.
Pressurized Fresh Water Model Parts Required • 1 1/2" (38mm) I.D. hose, approximately 3 feet (1m) long • Two buckets • Nontoxic antifreeze approximately 1 quart (1 liter) Steps 1. Close discharge seacock 2. Shut off intake water at source. 3.
INSTALLATION Parts Included All Toilets Toilet Bowl (Household or Marine) Seat and Cover Discharge pump assembly Heavy Duty Push Button Switch (#164000) Mounting pads Lower Motor Cover Sea Water Model.
SPECIFICATIONS Base Depth: 10 7/8" (27.6cm) Height: 17 3/8" (44.1cm) Household 17" (43.2cm) Marine Base Width: 10 1/2" (26.8cm) Bowl Width: 14 3/8" (36.6cm) Household 13" (33cm) Marine Bowl Depth: 19 1/4" (48.9cm) Household 16 3/4" (42.
Mounting T oilet Mounting surface must be flat and solid. IMPORTANT: Do not mount where it may be subject to shower spray or other sources of external water. 1. Install seat on toilet. 2. Place toilet where it will be located. Make sure there is room to route hoses.
Mounting Atmospheric Vacuum Breaker (Pressurized Freshwater Model only) 1. Install fittings as shown. 2. Locate mounting area that is a minimum of 6" (15.3cm) above toilet. 3. Secure where top is in horizontal position. Mounting In-Line Strainer (Seawater Models Only) Make sure strainer bowl is tight.
INSTALLATION PLUMBING WARNING: Hazard of Flooding Toilets mounted at or below the waterline must have a vented loop installed in the discharge line. The top of the vented loop must be a minimum of 4" (10cm) above the waterline at the boats greatest angle of heel (see vented loop manufacturer’s instructions).
Intake Lines Pressurized Freshwater Models Install a shut off valve in intake line before water solenoid valve. 1 . Connect hose from pressurized freshwater source to a shut off valve. 2. Connect hose from shut off valve to inlet port of water solenoid valve.
WIRING WIRING WARNING: Hazard of Shock and Fire • Always use proper wire, wire connectors and fuse/circuit breaker. See Specification Chart on page 7. • Secure wire properly. • Do not connect other appliances to toilet circuit. • Make sure power is off before proceeding.
Problem Possible Cause A1. Clogged or restricted discharge line. A2. Too many bends or ells in discharge line. A3. Clogged holding tank or vented loops. A4. Mineral buildup in hoses and fittings. A5. Low voltage. A6. Damage to pump wall. A7. Full holding tank.
Part # Description 1118 Lockwasher (4) 1222AW 90 Degree discharge (opt.) 1222B Straight discharge 1226B 1/4" - 20 S/S Hex Nut (4) 1234 Bowl Gasket 1236AW Bowl Spud Assembly 1236E Bowl Elbow 1237W.
C2M* CH55 CH92 1341 1222AW CH57 CH59 1234 CH38 1226B 1236E 1236AW 1237W, 1244AW, 1244W C246, 247 F149VT C250 CH26 CH18W CH121 CH120 F149VT CH119MW CH27 C290 1222B CH58 CH51 1118 M30 M31 161107 C253 CR.
530 Orange Street, Millville, NJ 08332 USA Telephone: 856-825-4900 FAX: 856-825-4409 www.raritaneng.com Southern Office and Plant: 3101 SW Second Avenue, Fort Lauderdale, FL 33315 USA Telephone: 954-525-0378 FAX: 954-764-4370 L339 0407kgs Specifications Subject to Change Without Notice Printed in U.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Raritan Engineering Crown Head II è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Raritan Engineering Crown Head II - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Raritan Engineering Crown Head II imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Raritan Engineering Crown Head II ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Raritan Engineering Crown Head II, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Raritan Engineering Crown Head II.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Raritan Engineering Crown Head II. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Raritan Engineering Crown Head II insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.