Manuale d’uso / di manutenzione del prodotto Tape Library PX502 del fabbricante Quantum
Vai alla pagina of 16
PX502 T ape Library Quick Start Guide TA B L E O F C O N T E N T S Introduction ....................................... 1 Notational Conventions ................. 1 Choosing a Location .......................... 2 Rack Space Requirements..............
PX502 T ape Library Quick Start Guide 2 Choosing a Location 0 When choosing an installation site for the PX502, consider the following requirements: • Rack Space Requirements • Environmental Conditions Rack Space Requi rements 0 Ta b l e 1 contains the rack requirements for the PX502 tape library .
PX502 T ape Library Quick Start Guide 3 By following these instructions, you help ensure that the system will continue to be safeguarded after it arrives at the installation site. Unpack and remove the following components from the packing materials (see figure 2 ): 1 Remove the accessories kit and set it aside.
PX502 T ape Library Quick Start Guide 4 T able 2 Rack Hole T ypes Figure Description Square rack holes are the most common type of rack holes. They can accept either cage nuts which mount from the back of the rail or clip nuts which clip on from the side of the rack rail.
PX502 T ape Library Quick Start Guide 5 T able 3 Library Mounting Hardware Qty Figure Description 16 Allen head screws (M5 x 10) for shelf assembly PN 90-87203-01 8 T - nuts (M5) PN 74-87575-01 4 metr.
PX502 T ape Library Quick Start Guide 6 Figure 4 Rack Mount Shelf Depth Requirements b Loosely attach the adjustable rack mount shelves (extenders and shelves) with 4 M5 x 10 Allen screws and T -nuts (see figure 7 ). Use these holes for rack depths of 27 in (68.
PX502 T ape Library Quick Start Guide 7 Figure 6 Rail Adapter T ypes d Attach the appropriate rail adapter to the front and back of the rack mount shelves (right and left) wit h 2 M5 x 10 Allen screws per adapter (see figure 7 ).
PX502 T ape Library Quick Start Guide 8 Figure 8 Installing the Rack Mount Shelves 3 Once the rack mount shelves are secured to the rack, tighten the Allen screws secu ring the adjustable shelves (right and left) together (see figure 9 ).
PX502 T ape Library Quick Start Guide 9 T able 4 Back Mounting Bracket Orientation Once the location is determined, attach the back brackets to each side of the library with four M5 x 8 Allen screws (see figure 10 ). Rack Depth Back Mounting Bracket (Mounting Position) Back Mounting Clamp #1 Holes #2 Holes 24 to 25 in.
PX502 T ape Library Quick Start Guide 10 3 Secure the back of the library to the rack with two mounting clamps (refer to table 4 for information on the correct mounting holes to use) and two M5 x 10 Allen screws on each clamp (see figure 12 ). 4 Secure the mounting clamps to the rack rails with two PHILLIPS screws on each side (see figur e 12 ).
PX502 T ape Library Quick Start Guide 11 • Figure 17 Native Fibre Channel System Controller Board Figure 15 PX502 Cable Configuration (SCSI System Controller Board) Figure 16 PX502 Cable Configuration (Surrogate) N OTE : Quantum ships suffici ent SCSI cables and terminators with the libraries to set up two-drives per SC SI bus.
PX502 T ape Library Quick Start Guide 12 Figure 18 T urning on the Library The power up sequence can take several minutes. The first message displaying will be “ Are the internal packaging materials.
PX502 T ape Library Quick Start Guide 13 5 After the library has powered down, remove the foam restraints by completing the following steps (see figure 20 ): a Detach the tie band holding the two sides of the metal restraints together and remove it from the library .
PX502 T ape Library Quick Start Guide 14 Setting the Library Options 0 T o set the library options: 1 T urn on the library by pushing power button located on the bottom left-hand corner of the OCP (see figure 18 ). 2 The OCP asks you: “ Are the packaging materials removed?” ( YES or NO ).
PX502 T ape Library Quick Start Guide 15 2 Use the up and down arrows to view or edit the time zone, date, and time information. Press Enter to accept the new settings. 3 When you are finished viewing/editing the date and time information, press Exit to return to the Setup screen.
PX502 T ape Library Quick Start Guide United States of America Quantum Corpora tion 141 Innovation Drive Irvine, CA 92612 U.S.A. phone 949.856.7800 fax 949.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Quantum Tape Library PX502 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Quantum Tape Library PX502 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Quantum Tape Library PX502 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Quantum Tape Library PX502 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Quantum Tape Library PX502, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Quantum Tape Library PX502.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Quantum Tape Library PX502. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Quantum Tape Library PX502 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.