INSTALLATION INSTRUCTIONS UFM Universal Flat Mount NORTH AMERICA EUROPE AUSTRALIA, NEW ZEALAND, OCEANIA (DISTRIBUTOR) 3130 East Miraloma Avenue Anaheim, CA 92806 USA USA and Canada – Phone: 800-368-.
- 2 - - Warnings 2 - Assembly drawing 3 - Flat panel list 4 - Parts list 6 9 h t p e d d a e r h t e h t g n i k c e h C - 0 1 y a l p s i d l e n a p t a l f e h t f o r e t n e c e h t g n i d n i F.
- 3 - 1 6.000 (406 . 4) 16 . 0 0 0 ( 406. 4) 1. 943 (49. 3) 5 .000 (1 2 7 ) 28 . 0 0 0 ( 171. 2) C L 3 .500 ( 88.9) C L 5. 0 0 0 (127) 16 . 0 0 0 ( 406. 4) 24 . 2 9 0 ( 616. 97) 16 . 0 0 0 ( 406. 4) 21. 790 (553 . 4) 1. 2 4 5 ( 31. 75) A B C D E F G H B A F H 21.
- 4 - Flat panel list Hitachi EIKI Electrograph Gateway 32HDT20,CMP307XJ,CMP307XU,32HD T20 CMP401HDU, CMP402HDE, CMP402HDU, CMP4120HDU,CMP4121,CMP4121HDU,CMP4201U, CMP4202U, 42HDW10,42HDT20, 42HD T50,.
- 5 - SONY Sanyo VIEWSONIC Sampo PDP421A: M5 x 20 - ¼” nylon spacer (small) PDP42H1NA: M5 x 20 - ¼” nylon spacer (small) VPW420: M8 x 30 – ½” nylon spacers - sleeves VPW425: M8 x 30 – ¼.
- 6 - (Qt y 8) (Qty 8) M6 x 1 2 M5 x 50 M5 x 16 M5 x 25 M5 x 20 M5 x 12 M4 x 25 M4 x 16 M8 x 70 M8 x 35 (Qty 4) (Qty 4) (Qty 6) (Qty 4) (Qty 6) M8 x 30 M8 x 25 (Qty 4 ) M8 x 2 0 (Qty 6 ) (Qty 6) (Qty 6) (Qty 4 ) (Qty 8) M6 x 20 (Qty 6 ) Parts list This wall m ount is ship ped wit h all proper inst allation har dware and c omponents.
- 7 - 1/4" Ny lon spacers 5/16 " Fl at w a s h er s (metal) 1 " Ny lon s p ac ers 1/4 " N yl on s pac e r s 9/16 " Nylo n s pacers (l arge ) (small) 1/2" Ny lon spacers (.
- 8 - Parts list (con’t) Level (1) 5/16" flat washers (4) 5/16" x 3" La g bolts (4) (used on w ood studs only) Griplates™ (8) Wall plate (1) Mounting brac ket s (left & right) All of these parts are use d to install the mounti ng bracket.
- 9 - Checking the thread depth on your flat panel Inverted flat panel display Thread insert Thread depth indicator Figure 2 Figure 3 Figure 1 Markin g the de p th 1. Insert the thread depth indicator (supplied) through the thread inserts found on the back of the flat panel to make sure the inserts measure the sam e full depth and mark it.
- 10 - C L L C Finding center of the flat panel display Once the flat panel is inverted, use a measuring tape to find the center of your flat panel measuring fro m outside to outside of the chassis. See figure 1. Using a pencil lightly mark the center of your flat panel.
- 11 - Positioning the mounting brackets Inverted flat p anel Nylon spacers if Applicable ( see chart ) on p a g e 4 and 5 Center mar k Bottom of flat panel Install the nylon spacers to the mounting points on the flat panel see figure 3. Lay the left and right m ounting brackets (stamped arrows facing out).
- 12 - C L Bottom of flat panel Align the mounting brackets The mountin g brackets are designe d with a center o f viewing guide on the side of them . See figure 6. Bottom of flat panel Mounting bracket Center of flat panel Center of viewing guide Match the cent er of viewing gui de with the center line you marke d in step 1.
- 13 - DIMPLES FACING UP 3/4" DIMPLES FACING UP DIMPLES FA CING DOWN DIMPLES FAC ING DOW N Securing the mounting brackets The Griplates™ have M4, M5 M6 and M8 hole patterns to fit the hardware that your flat panel requires. EXAMPLE : If your plasma uses M8 x 20 Phillip screws.
- 14 - 16" 16" Finding the wood studs behind the wall structure Using a (commercially available) wood stud finder, locate the 16" or 24" stud centers behind the wall. Once found, make a pencil marking on the center of the wood studs.
- 15 - 16" 16" Marking the mounting points on the wall Place the bottom portion of the wall plate to the reference line and mark the four (4) lag bo lt mounting points through the wall plate slots on the wall. Level the wall plate with the reference arrow pointing up to the ceiling.
- 16 - Securing the wall plate to wood studs Wall p late (4) 5/16" x 3" lag bolts and (4) flat washers (supplied) Level and secure the p late to the wall with the reference arrow facing up to the ceiling. Secure the plate using the four (4) 5/16" lag bolts and flat washers (supplied).
- 17 - Securing the wall plate to a concrete wall Level and secure the plate to the wall with the reference arrow facing up to the ceiling. Use a min dia of 5/16” x 2 ¼” lg concrete wedge anchors (commercially available). See figure 14. Use a minimum diameter of 5/16” x 2 ¼” long wedge anchors (commercially available).
- 18 - AT LEAST (2) QUALIFIED PERSONNEL ARE STRONGLY RECO MMENDED FOR INSTALLATION OF T HIS PRODUCT. FAILURE TO DO SO COULD RESULT IN SERIOUS INJURY AND POS SIBLE DAMAGE TO THE FLAT PANEL.
- 19 - Make any lateral shift adjustment and lock it b y tighten ing the two (2) ¼”-20 Phillips screws found on the bottom of the mounting brackets.
- 20 - PREMIER MOUNTS LIMITED LIFETIME WARRANTY What and Who is Covered by this Limited Warranty and for How Long Premier Mounts warrants this product to be free from defect s in material and workmans hip for the lifetime of the original installation of this product.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Premier Mounts Universal Flat-Only Mount UFM è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Premier Mounts Universal Flat-Only Mount UFM - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Premier Mounts Universal Flat-Only Mount UFM imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Premier Mounts Universal Flat-Only Mount UFM ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Premier Mounts Universal Flat-Only Mount UFM, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Premier Mounts Universal Flat-Only Mount UFM.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Premier Mounts Universal Flat-Only Mount UFM. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Premier Mounts Universal Flat-Only Mount UFM insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.