Manuale d’uso / di manutenzione del prodotto 525AP del fabbricante Powercom
Vai alla pagina of 17
U P S Uninterruptible Power System Line Interactive UPS 325A/425A/525A/625A Line Interactive Network UPS 425AP/525AP/625AP USER ‘ S MANUAL.
Important safety instructions __________________________________________________________ _____ Thank you for selecting this uninterruptible power system (UPS).
Table of contents __________________________________________________________ ____ 1. Introduction ……… ……… ………… ……… … ..1 2. Safety ………… …………… ………… ………… 2 3. Presentation Front Panel. … ……………… ……………… 3 Rear Panel.
1. INTRODUCTION __________________________________________________________ _____ The product is line interactive UPS with the newest technology and powerful function. The LINE INTERACTIVE ups is with AVR function allows input voltage range from 75% to 125%, including on line voltage boost-up & buck down.
2. Safety __________________________________________________________ _____ CAUTION ! ● To reduce the risk of electric shock, disconnect the UPS from the mains supply before installing a computer interface signal cable. Reconnect the power cord only after signaling interconnections have been made.
3. Presentation __________________________________________________________ ____ FRONT PANEL 3.1 "REPLACE BATTERY" indicator (RED LED) The LED illuminates when the UPS's battery is no longer useful and must be replaced.
__________________________________________________________ __ REAR PANEL 3.5 COMPUTER INTERFACE (425AP/525AP/625AP models only) Provide both RS-232 and relay signal to support NOVELL, UNIX, DOS, WINDOWS and other operating systems. 3.6 OUTPUT POWER RECEPTACLES 3.
4. Installation __________________________________________________________ ____ 4.0 Inspection Inspect the UPS upon receipt. The packaging is recyclable; save it for reuse or dispose of it properly. 4.1 Placement Install the UPS in a protected area with adequate air flow and free of excessive dust.
4.5 Connect the loads Plug the loads into the output connectors on the rear of the UPS. To use the UPS as a master on/off switch, make sure all of the loads are switched on. Caution: Never connect a laser printer or plotter to the UPS with other computer equipment.
5. Operation __________________________________________________________ ____ 5.1 Switch on With the UPS plugged in, press and hold the on/off/test/silence button more than 1 second until "LINE NORMAL" LED lit to switch the ups on. The UPS will perform self-testing each time when it is switched on.
6. Alarm __________________________________________________________ _____ 6.1 "BACK UP" (slow alarm) When in BACK UP mode, the YELLOW LED illuminates and the UPS sounds an audible alarm. The alarm stops when the UPS returns to LINE NORMAL operation.
7. Software options __________________________________________________________ ____ 7.1 UPSMON Software The UPSMON software is applied standard RS-232 interface to perform monitoring functions, and then provides an orderly shutdown of a computer in the event of power failure.
8. Computer Interface Port __________________________________________________________ ____ The computer interface port has the following characteristics:.
9. Battery Replacement __________________________________________________________ ____ Your battery should run any where from 3-5 years before eve needing to be replaced. Please follow the instructions below for easy battery replacement. 1) Unplug unit from AC power source and disconnect all connected equipment.
10. Troubleshooting __________________________________________________________ ____ PROBLEM POSSIBLE CAUSE ACTION TO TAKE On/off/test/silence button not pushed or push too short Press the on/off/test/.
11. Storage __________________________________________________________ ____ 10.1 Storage conditions Store the UPS covered and upright in a cool , dry location, with its battery fully charged.
Typical Recharge Time 4 hours (to 90% of full capacity) Protection Automatic self-test & discharge protection, replace battery indicator Back up Time 10 - 30 minutes (depending on computer load) Net Weight Kg(lbs) 4.7(10.4) 5.8(12.8) 6.2(13.7) 6.5(14.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Powercom 525AP è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Powercom 525AP - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Powercom 525AP imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Powercom 525AP ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Powercom 525AP, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Powercom 525AP.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Powercom 525AP. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Powercom 525AP insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.