Part No. D21683-0111-1 Oilfr ee Compressor Instruction manual T o learn more about Porter -Cable visit our website at: http://www .porter -cable.com The Model and Serial No. plate is located on the frame. Record these numbers in the spaces below and retain for futur e reference.
2-ENG CAUTION indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury . This manual contains information that is important for you to know and understand. This infor - mation relates to pr otecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS .
3-ENG RISK OF BURSTING IT IS NORMAL FOR ELECTRICAL CONT ACTS WITHIN THE MOTOR AND PRESSURE SWITCH TO SP ARK. IF ELECTRICAL SP ARKS FROM COMPRESSOR COME INTO CONT ACT WITH FLAMMABLE V APORS, THEY MA Y IGNITE, CAUSING FIRE OR EXPLOSION. RESTRICTING ANY OF THE COMPRESSOR VENTILA TION OPENINGS WILL CAUSE SERIOUS OVERHEA TING AND COULD CAUSE FIRE.
4-ENG RISK FROM FL YING OBJECTS IMPORT ANT SAFETY INSTRUCTIONS (cont’d) THE COMPRESSED AIR STREAM CAN CAUSE SOFT TISSUE DAMAGE TO EXPOSED SKIN AND CAN PROPEL DIRT , CHIPS, LOOSE P ARTICLES AND SMALL OBJECTS A T HIGH SPEED , RESUL TING IN PROPERTY DAMAGE OR PERSONAL INJUR Y .
5-ENG RISK FROM MOVING P ARTS RISK OF BURNS RISK OF F ALLING IMPORT ANT SAFETY INSTRUCTIONS (cont’d) WHA T CAN HAPPEN HOW TO PREVENT IT WHA T CAN HAPPEN HOW TO PREVENT IT WHA T CAN HAPPEN HOW TO PREVENT IT MOVING P AR TS SUCH AS THE PULLEY , FL YWHEEL, AND BEL T CAN CAUSE SERIOUS INJURY IF THEY COME INTO CONT ACT WITH YOU OR YOUR CLOTHING.
6-ENG CFM: Cubic feet per minute. SCFM: Standar d cubic feet per minute; a unit of measure of air delivery . PSIG: Pounds per square inch gauge; a unit of measur e of pressur e. ASME: American Society of Mechanical Engineers; made, tested, inspected and register ed to meet the standards of ASME.
7-ENG DESCRIPTION OF OPERA TION Drain V alve (not shown): The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use. Motor Thermal Overload Protector (not shown): The electric motor has an automatic thermal overload protector .
8-ENG INST ALLA TION Location of the Air Compressor Locate the air compressor in a clean, dry , and well-ventilated area. The air filter must be kept clear of obstructions which could reduce air flow to the air compressor .
9-ENG V oltage and Circuit Protection Refer to the specification chart for voltage and circuit protection requirements of your compressor . Use only a fuse or circuit br eaker that is the same rating as the branch circuit on which the air compr essor is operated.
10-ENG BREAK-IN PROCEDURES Serious damage may result if the following break-in instructions are not closely followed. This procedur e is required befor e the air compressor is put into service. (befor e the hose is installed), the check valve is replaced, or a complete compr essor pump is replaced.
11-ENG SERVICE INSTRUCTIONS Air Filter - Inspection and Replacement Hot surfaces. Risk of burn. Compressor heads are exposed when filter cover is removed. Allow compr essor to cool prior to servicing. Keep the air filter clean at all times. Do not operate the compressor with the air filter r emoved.
12-ENG Check V alve Replacement 1. Release all air pressur e fr om air tank and unplug outfit. 2. Remove shroud. 3. Loosen the top and bottom nuts and remove the outlet tube. 4. Remove the pressur e release tube and fitting. 5. Unscrew the check valve using a socket wr ench.
13-ENG CAUSE PERFORMING REP AIRS MA Y EXPOSE VOL T AGE SOURCES, MOVING P ARTS OR COMPRESSED AIR SOURCES. PERSONAL INJUR Y MA Y OCCUR. PRIOR TO A TTEMPTING ANY REP AIRS, UNPLUG THE AIR COMPRESSOR AND BLEED OFF ALL AIR T ANK AIR PRESSURE. PROBLEM CORRECTION TROUBLESHOOTING GUIDE Excessive tank pressur e - safety valve pops off.
14-ENG CAUSE PROBLEM CORRECTION Motor will not run or restart. Motor overload protection switch has tripped. T ank pressur e exceeds pressur e switch “cut-in” pressur e. Wr ong gauge wire or length of extension cord. Check valve stuck open. Loose electrical connections.
15-ENG Operate safety valve manually by pulling on ring. If valve still leaks, it should be replaced. Possible defect in safety valve. Air leak from safety valve. CAUSE PROBLEM CORRECTION Knocking Noise. Defective check valve. Remove and clean, or replace.
16-ENG ACCESSORIES Accessories can be found at the store the unit was pur chased or at a local hardwar e store. PLUMBING COMPONENTS CONNECTORS Connects components that have similar NPT threads; Male or Female. 360 O SWIVEL CONNECTOR Eliminates hose twist and improves tool handling.
17-ENG NOTES.
18-ENG LIMITED WARRANTY PORTER-CABLE CORPORA TION warrants to the original purchaser that each new air compressor and service part is fr ee from defects in material and workmanship and agrees to repair or r eplace under this warranty any defective product or part as follows fr om the original date of purchase.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Porter-Cable CPFC2TV3525VP è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Porter-Cable CPFC2TV3525VP - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Porter-Cable CPFC2TV3525VP imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Porter-Cable CPFC2TV3525VP ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Porter-Cable CPFC2TV3525VP, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Porter-Cable CPFC2TV3525VP.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Porter-Cable CPFC2TV3525VP. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Porter-Cable CPFC2TV3525VP insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.