Manuale d’uso / di manutenzione del prodotto CPF6020 del fabbricante Porter-Cable
Vai alla pagina of 18
Part No. D20814-004 Oilfr ee Compr essors Instruction manual T o learn more about Porter -Cable visit our website at: http://www .porter -cable.com The Model and Serial No. plate is located on the frame. Record these numbers in the spaces below and retain for future reference.
2-ENG CAUTION indicates a potentially hazar dous situation which, if not avoided, may result in minor or moderate injury . This manual contains information that is important for you to know and understand. This infor - mation relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS .
3-ENG RISK OF BURSTING IT IS NORMAL FOR ELECTRICAL CONT ACTS WITHIN THE MOTOR AND PRESSURE SWITCH TO SP ARK. IF ELECTRICAL SP ARKS FROM COMPRESSOR COME INTO CONT ACT WITH FLAMMABLE V APORS, THEY MAY IGNITE, CAUSING FIRE OR EXPLOSION. RESTRICTING ANY OF THE COMPRESSOR VENTILA TION OPENINGS WILL CAUSE SERIOUS OVERHEA TING AND COULD CAUSE FIRE.
4-ENG RISK FROM FL YING OBJECTS IMPORT ANT SAFETY INSTRUCTIONS (cont’d) THE COMPRESSED AIR STREAM CAN CAUSE SOFT TISSUE DAMAGE TO EXPOSED SKIN AND CAN PROPEL DIRT , CHIPS, LOOSE P ARTICLES AND SMALL OBJECTS A T HIGH SPEED , RESUL TING IN PROPERTY DAMAGE OR PERSONAL INJUR Y .
5-ENG RISK FROM MOVING P ARTS RISK OF BURNS RISK OF F ALLING IMPORT ANT SAFETY INSTRUCTIONS (cont’d) WHA T CAN HAPPEN HOW TO PREVENT IT WHA T CAN HAPPEN HOW TO PREVENT IT WHA T CAN HAPPEN HOW TO PREVENT IT MOVING P ARTS SUCH AS THE PULLEY , FL YWHEEL, AND BEL T CAN CAUSE SERIOUS INJUR Y IF THEY COME INTO CONT ACT WITH YOU OR YOUR CLOTHING.
6-ENG CFM: Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measur e of air delivery . PSIG: Pounds per square inch gauge; a unit of measur e of pressure. ASME: American Society of Mechanical Engineers; made, tested, inspected, and register ed to meet the standards of ASME.
7-ENG DESCRIPTION OF OPERA TION Drain V alve (not shown): The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use. Motor Thermal Overload Protector (not shown): The electric motor has an automatic thermal overload protector .
8-ENG INST ALLA TION Installing Handles, Wheel, and Rubber Foot (Fig. 2) THE WHEELS AND HANDLE DO NOT PROVIDE ADEQUA TE CLEARANCE, ST ABILITY OR SUPPORT FOR PULLING THE UNIT UP AND DOWN ST AIRS OR STEPS. THE UNIT MUST BE LIFTED, OR PUSHED UP A RAMP . 1.
9-ENG Location of the Air Compr essor Locate the air compressor in a clean, dry , and well-ventilated area. The air filter must be kept clear of obstructions which could r educe air flow to the air compr essor . The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air .
10-ENG GROUNDING INSTRUCTIONS RISK OF ELECTRICAL SHOCK! In the event of a short circuit, gr ounding reduces the risk of shock by providing an escape wire for the electric current.
11-ENG BREAK-IN PROCEDURES Serious damage may result if the following break-in instructions ar e not closely followed. This pr ocedure is r equir ed befor e the air compressor is put into service. (before the hose is installed), the check valve is r eplaced, or a complete compressor pump is replaced.
12-ENG SERVICE INSTRUCTIONS Air Filter - Inspection and R Air Filter - Inspection and R Air Filter - Inspection and R Air Filter - Inspection and R Air Filter - Inspection and R eplacement eplacement eplacement eplacement eplacement Keep the air filter clean at all times.
13-ENG 5. Unscr ew the check valve using a socket wrench. 6. Check that the valve disc moves freely inside the check valve and that the spring holds the disc in the upper , closed position. The check valve may be cleaned with a strong solvent. 7. Apply sealant to the check valve threads.
14-ENG CAUSE PERFORMING REP AIRS MA Y EXPOSE VOL T AGE SOURCES, MOVING P ARTS OR COMPRESSED AIR SOURCES. PERSONAL INJUR Y MA Y OCCUR. PRIOR TO A TTEMPTING ANY REP AIRS, UNPLUG THE AIR COMPRESSOR AND BLEED OFF ALL AIR T ANK AIR PRESSURE. PROBLEM CORRECTION TROUBLESHOOTING GUIDE Excessive tank pressure - safety valve pops off.
15-ENG CAUSE PROBLEM CORRECTION Motor will not run or restart. Motor overload pr otection switch has tripped. T ank pressure exceeds pr essure switch “cut-in” pr essure. W rong gauge wire or length of extension cor d. Check valve stuck open. Loose electrical connections.
16-ENG Operate safety valve manually by pulling on ring. If valve still leaks, it should be replaced. Possible defect in safety valve. Air leak from safety valve. CAUSE PROBLEM CORRECTION Knocking Noise. Malfunctioning check valve. Remove and clean, or replace.
17-ENG ACCESSORIES Accessories can be found at the stor e from which the unit was purchased or at a local hardware store. PLUMBING COMPONENTS CONNECTORS Connects components that have similar NPT threads; Male or Female. 360 O SWIVEL CONNECTOR Eliminates hose twist and improves tool handling.
18-ENG LIMITED WARRANTY POR TER-CABLE CORPORA TION warrants to the original purchaser that each new air compressor and service part is free fr om defects in material and workmanship and agrees to repair or replace under this warranty any defective pr oduct or part as follows fr om the original date of purchase.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Porter-Cable CPF6020 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Porter-Cable CPF6020 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Porter-Cable CPF6020 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Porter-Cable CPF6020 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Porter-Cable CPF6020, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Porter-Cable CPF6020.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Porter-Cable CPF6020. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Porter-Cable CPF6020 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.