D YN A-PRO TM CENTRIFUGAL PUMPS WITH INTEGRAL TRAP O W N E R’ S M A N U A L INST ALLA TION, OPERA TION & P ARTS Series MPRA, MPEA, and MPE See P age 3 for Model Numbers Pentair Water Pool and Spa, Inc. Sanford, N.C., Moor p ark, CA, USA Ontario, Canada Herentals, Belgium S771 (Rev.
2 T echnical Suppor t Sanford, North Carolina (8 A.M to 5 P.M.) Phone: (800) 831-7133 Moorpark, California (8 A.M to 5 P.M.) Phone: (800) 831-7133 Fax: (80 0 ) 284-4151 Websites: visit www.pentairpool.com and staritepool.com © 200 8 Pentair Water Pool and Spa, Inc.
3 ‘MPRA ’, ‘MPEA ’ & ‘MPE’ SERIES PUMPS WITH TRAP To avoid unneeded service calls, prevent possible in- juries, and get the most out of your pump, READ THIS MANUAL CAREFULLY! The Sta-R.
4 1. Do not connect system to a high pressure or city water system. 2. Use equipment only in a pool or spa installation. 3. Trapped air in system can cause explosion.
5 Allow pump suction inlet height to be as close to water level as possible. Pump will not lift water more than 10' (3m). Allow use of short, direct suction pipe (To reduce friction losses). Allow for gate valves in suction and discharge piping. Have adequate floor drainage to prevent flooding.
6 W ater V elocity The maximum water velocity through the suction fitting or cover for any suction outlet must not exceed 1.5 feet per second unless the outlet complies with the latest ANSI/ASME Specification for Suction Fittings For Use in Swimming Pools, Spas, Hot Tubs, and Whirlpool Bathtub Applications.
7 Grounding/Bonding Install, ground, bond and wire motor according to local or National Electrical Code requirements. Permanently ground motor. Use green ground terminal provided under motor canopy or access plate (See Figure 4); use size and type wire required by code.
8 T ABLE I - RECOMMENDED CIRCUIT BREAKER AND WIRING D A T A Serv. to Motor - Dist. in Ft. (M) Motor Branch CB Max Load Voltage/ 0-100' 101-200' 201-300' HP Rating Amps Amps Hz/Phase (0-30) (30-60) (60-90) MPRA SERIES – SINGLE SPEED 3/4 20/15 13.
9 OPERA TION NOTICE: NEVER run pump dry. Running pump dry may damage seals, causing leakage and flooding. Fill pump with water before starting motor. Before removing trap cover: 1. STOP PUMP before proceeding. 2. CLOSE GATE VALVES in suction and discharge pipes.
10 For outdoor/unprotected installations: 1. Enclose entire system in a weatherproof enclosure. 2. To avoid condensation/corrosion damage, allow venti- lation; do not wrap system in plastic. 3. Use a 40% propylene glycol/60% water solution to protect pump to -50°F (-46°C).
11 If shaft seal is worn or damaged, repair as follows: Pump D issasem bly/R emo ving Old Seal Disconnect power to pump motor. Be sure valves on suction and return piping are closed before starting work. Release all pressure by opening all vents before starting work.
12 TROUBLESHOOTING GUIDE Read and understand safety and operating instruc tions in this manual before doing any work on pump! Only qualified personnel should electrically test pump motor! FAILURE TO PUMP; REDUCED CAPACITY OR DISCHARGE PRESSURE Suction leaks/lost prime: 1.
13 1 2 3 4 5 6 7 8 8 A 8 B See Bo x A See Bo x A 11 12 13 14 15B 15A 16 17 1 8 19 20 21 22 23 24 9 10 REP AIR P AR TS LIST D YNA-PRO™ POOL PUMP 1/2 thr ough 2-1/2 HP Models Single Speed and T wo Speed Model No.
14 MPEA6G-207L MPEA6F-206L MPE6F-207L MPEAA6G-208L MPEA6D-204L MPEA6E-205L MPE6E-206L MPEA6YG-207L MPE6G-208L Key Part MPE6C-204L MPE6D-205L MPRA6F-206L MPE6YF-207L MPEAA6YG-208L No.
15.
P/N S771 Rev . B 2/8/08.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Pentair MPE è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Pentair MPE - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Pentair MPE imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Pentair MPE ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Pentair MPE, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Pentair MPE.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Pentair MPE. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Pentair MPE insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.