Pelco • 3500 Pelco Way • Clovis, CA 93612-5699 USA • www.pelco.com In North America and Canada: Tel (800) 289-9100 or FAX (800) 289-9150 International Customers: Tel +1 (559) 292-1981 or FAX +1 .
[ 2 ] Pelco Manual C527M-L (3/04).
Pelco Manual C527M-L (3/04) [ 3 ] CONTENTS Section Page IMPORT ANT SAFETY INSTRUCTIONS .................................................................................................. ......... 5 REGULA TORY NOTICES .................................
[ 4 ] Pelco Manual C527M-L (3/04) List of Illustrations Figure Page 1 Wiring Diagram for Local/Remote Keyboards ................................................................................... 10 2 Keyboard Cabling Diagram .........................
Pelco Manual C527M-L (3/04) [ 5 ] IMPORT ANT SAFETY INSTRUCTIONS Read these instructions. Keep these instructions. Heed all warnings. Follow all instructions. Do not use this apparatus near water . Clean only with dry cloth. Do not block any ventilation openings.
[ 6 ] Pelco Manual C527M-L (3/04) REGULA TORY NOTICES This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference re- ceived, including interference that may cause undesired operation.
Pelco Manual C527M-L (3/04) [ 7 ] DESCRIPTION The KBD300A Universal Keyboard has many operational features (refer to T able A) and can be used in nu- merous operational modes: CM6700 Mode: Program and operate the CM6700 Matrix Switcher/Controller Unit (SCU).
[ 8 ] Pelco Manual C527M-L (3/04) T able A. KBD300A Operational Features CM6700/ Direct CM6700 CM6800 Direct Function CM6800 P* ASCII** ASCII** D** Automatically recognize the mode Y es Y es No No No .
Pelco Manual C527M-L (3/04) [ 9 ] INST ALLA TION – CM6700 MODE There are two keyboard ports on the CM6700 SCU. The LOCAL KEYBOARD port is for connecting a single keyboard within a distance of 25 feet (7.6 meters). The REMOTE KEYBOARD(S) port is for connecting additional remote keyboards.
[ 10 ] Pelco Manual C527M-L (3/04) Figure 1. Wiring Diagram for Local/Remote Keyboards Figure 2. Keyboard Cabling Diagram KBDKIT 25-FOOT KEYBOARD DAT A CABLE KBD KBD ADDITIONAL KEYBOARDS USER-SUPPLIED.
Pelco Manual C527M-L (3/04) [ 11 ] INST ALLA TION – CM6800 MODE Y ou can connect up to eight KBD300A keyboards to any of the following ports: For the CM6800-48X8: COM 5 (one direct-powered keyboard .
[ 12 ] Pelco Manual C527M-L (3/04) Figure 3. Data Cables Plugged into COM 5 and 6 (CM6800-48X8 Shown) COM 1 1 2 3 4 5 6 7 8 16 8 7 32 31 4 3 VI DE O O UTPUTS 120/ 230~ 50/ 60 HZ 25 W ATTS COM ALAR M 1.
Pelco Manual C527M-L (3/04) [ 13 ] Connecting KBD300A Remote Keyboards For remote keyboard connections, use COM 5, 6, 7, or 8 for the CM6800-48X8 and COM 4 and 5 for the CM6800-32X6. Each port can support up to eight KBD300A keyboards. Do not exceed 16 total keyboards for the CM6800-48X8 and eight total keyboards for the CM6800-32X6.
[ 14 ] Pelco Manual C527M-L (3/04) Figure 4. Connecting Remote Keyboards (CM6800-48X8 Shown) COM 1 1 2 3 4 5 6 7 8 16 8 7 32 31 4 3 VI DE O O UTPUTS 120/ 230~ 50/ 60 HZ 25 WA TTS COM ALAR M 123 45 678.
Pelco Manual C527M-L (3/04) [ 15 ] INST ALLA TION – CM6700 ASCII MODE One ASCII keyboard can be installed, using either an RS-232 or RS-422 interface.
[ 16 ] Pelco Manual C527M-L (3/04) Set the keyboard DIP switches for ASCII Mode according to the instructions in the Switch Settings section. Plug in the keyboard data cable. Plug the +12 VDC power supply into a suitable outlet. Plug the KBDKIT or KBDKIT -X transformer into a suitable outlet.
Pelco Manual C527M-L (3/04) [ 17 ] RS-422 Interface (CM6700) Refer to Figure 6. Remove the cover from the CM6700 SCU and verify that the DIP switches for COM 2 are set for RS-422. Refer to the COM 2 Port section in the CM6700 Installation/Operation Manual for setting the switches.
[ 18 ] Pelco Manual C527M-L (3/04) KBDKIT RJ-45 WALL BLOCK TERMINALS POWER UP SCU REPLACE COVER SCU COM 2 PIN 12 (RX+) 11 (RX-) 8 (TX-) 7 (TX+) WALL BLOCK TERMINAL 1 (TX+) 2 (TX-) 7 (RX-) 8 (RX+) TO 1.
Pelco Manual C527M-L (3/04) [ 19 ] INST ALLA TION – CM6800 ASCII MODE RS-232 Interface (CM6800) An RS-232/RS-422 converter and power supply (Pelco part number PV130) are required. They are not included and must be ordered separately . Refer to Figures 7 (CM6800-48X8 shown) and 9.
[ 20 ] Pelco Manual C527M-L (3/04) Apply power to the CM6800 (if not already powered). T o initialize the keyboard, wait five seconds after power -up, enter the number for the monitor you are viewing, and press MON. The LED display shows the number entered.
Pelco Manual C527M-L (3/04) [ 21 ] RS-485 Interface (CM6800) Refer to Figures 8 (CM6800-48X8 shown) and 9. Use an existing CM6800 keyboard to program the COM 4, 7, or 8 communication port (CM6800-48X8) or COM 4 communications port (CM6800-32X6). (If there is no other keyboard, use the one you are installing.
[ 22 ] Pelco Manual C527M-L (3/04) COM 1 1 2 3 4 5 6 7 8 16 8 7 32 31 4 3 VI DEO OU TPUTS 120/ 230~ 50/60 HZ 25 W ATTS COM ALARM 123 45 6 78 CONT ROL PTZ OUT AT + T - R + R - T + T - R + R - B 1 2 F 3 COM 4, 7, OR 8 6 NOTE: A SEPARA TE PA TH MUST BE PROVIDED FOR VIDEO TO THE MONITOR.
Pelco Manual C527M-L (3/04) [ 23 ] PIN 1 PIN 8 COM PORTS 1, 2 RS-232 PIN 1 PIN 8 COM PORT 3 M, RS-485 PIN 1 PIN 8 COM PORT 4 RS-485 PIN 1 PIN 8 COM PORTS 5, 6 RS-485 1-----Rx 2-----NC 3-----NC 4 5----.
[ 24 ] Pelco Manual C527M-L (3/04) INST ALLA TION – DIRECT MODE The keyboard is wired directly to a maximum of 16 receivers. Y ou can communicate using Pelco P Protocol or Pelco D Protocol. Direct Mode installation/operation is not the same as CM6700 Mode or CM6800 Mode installation/operation.
Pelco Manual C527M-L (3/04) [ 25 ] Figure 10. Direct Keyboard and Receiver Wiring 6 REPLACE COVER 2 3 4 5 6 7 18 KBD300A 25-FOOT KEYBOARD DATA CABLE TO RECEIVER(S) RX-/RX+ TWISTED PAIR 12 V A C TX- TX.
[ 26 ] Pelco Manual C527M-L (3/04) SWITCH SETTINGS To set the switches on the keyboard (refer to Figure 11): Remove the two screws and the DIP switch cover plate from the rear of the keyboard. Set the switches: • Address (Switches 1-4) Position the switches according to T able B.
Pelco Manual C527M-L (3/04) [ 27 ] PROGRAMMING AND OPERA TION T able D. Keyboard Functions Circled numbers refer to Figure 13. Function Procedure Select Monitor* LED display shows monitor number in run mode. Enter monitor number and press MON to select.
[ 28 ] Pelco Manual C527M-L (3/04) T able D. Keyboard Functions (continued) Function Procedure Patterns Programming and operation varies with the receiver type. Spectra ® domes (before version 3.0) can use one long (1 minute) or two short (0.5 minute) patterns.
Pelco Manual C527M-L (3/04) [ 29 ] T able D. Keyboard Functions (continued) Function Procedure Auxiliaries/ For the CM6700: Relays F1 – F3 control only the auxiliaries built into the CM6700 SCU. These outputs can be programmed for momentary , keyed, latched, or alarm op- eration.
[ 30 ] Pelco Manual C527M-L (3/04) Figure 12. Keyboard Functions T able E. KBD300A Button Functions Reference Number Description 1 LED display 2 Shift key 3 Shift key LED 4A-C Sequence keys: Previous, Next, Hold 5 Function keys F1/Latch, F2/Off, F3/Mom control auxiliaries.
Pelco Manual C527M-L (3/04) [ 31 ] T able F . Operating Scan Functions with V arious Receivers Function Receiver Controlling Auto Random Frame Preset Stop Model Protocol Scan Scan Scan Scan All 15-bit.
[ 32 ] Pelco Manual C527M-L (3/04) Programming Limit Stops Spectra and Esprit can be programmed for scan and manual limit stops. Program left limit before programming right limit. Locate camera at desired limit. Enter the set code from T able G. Hold the PRESET key for two seconds.
Pelco Manual C527M-L (3/04) [ 33 ] Zones The Zone function is available on Esprit and Spectra positioning systems when operated through a CM6700 or CM6800 switch.* This function puts a label on the screen to identify the viewing area. Zones can also be blanked to prevent viewing while the camera is positioned in the zone.
[ 34 ] Pelco Manual C527M-L (3/04) SPECIFICA TIONS GENERAL Keyboard Keypad: Electromechanical Joystick: 3-axis, vector -solving, with twisting, return-to-center head Digital Display: Red LED, 7-segmen.
Pelco Manual C527M-L (3/04) [ 35 ] CM6800 ASCII Mode Interface: RS-485 Protocol: Pelco ASCII Baud: 9600 Communication Parameters: 8 data bits, 1 stop bit, odd parity Direct P Mode Interface: RS-485 Pr.
[ 36 ] Pelco Manual C527M-L (3/04).
Pelco Manual C527M-L (3/04) [ 37 ] REVISION HISTOR Y Manual # Date Comments C527M 11/97 Original version. C527M-A 1/98 Revised manual to include Direct Mode Installation/Operation instructions. Added CM6700 Operations instructions. C527M-B 4/98 Revised installation instructions as a result of hardware changes to the rear panel of the CM6700 SCU.
.
Pelco, the Pelco logo, Camclosure, Esprit, Genex, Legacy , and Spectra are registered trademarks of Pelco. Endura and ExSite are trademarks of Pelco. © Copyright 2004, Pelco.
W orld Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Pelco KBD300A è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Pelco KBD300A - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Pelco KBD300A imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Pelco KBD300A ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Pelco KBD300A, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Pelco KBD300A.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Pelco KBD300A. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Pelco KBD300A insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.