System 974 0 ™ Soft ware Upgrade ® INST ALLA TION MANUAL C1547M (7/03) CM9740-UPG-8312.
.
CONTENTS Section Page INTRODUCTION .................................................................................................................................................................................................................. 1 SOFTW ARE UPGRADE OVERVIEW .
.
C1547M (7/03) 1 INTRODUCTION The CM9740-UPG-8312 software upgrade kit provides the following items to upgrade System 9740 ™ software: 1 System 9740 Setup Disk, version 3.74 1 System 9740 Operation Disk, version 8.03.012 1 System 9740 Utility Disk, version 8.
2 C1547M (7/03) SOFTWARE UPGRADE OVERVIEW Upgrading System 9740 software to version 8.03.012 involves upgrading CM9740-CC1 software and System Manager software. For proper operation of a 9740 system, however , additional components—such as CM9740-MXB and CM9760-KBD/ CM9760-KBR firmware—must also be upgraded.
C1547M (7/03) 3 UPGRADING SYSTEM 9740 SOFTW ARE IN A SINGLE-NODE SYSTEM NOTE: Any external computer interface (such as an access control system, alarm system, fire system, building management/ control system, or VMX200) that is using the P protocol to communicate with a CM9740-CC1 running version 7.
4 C1547M (7/03) b. Remove the current System Manager program: (1) In the Windows taskbar , click the Start button. (2) Highlight Settings and then click Control Panel .
C1547M (7/03) 5 9. Upgrade the CC1 system software executable file, CM9740.EXE: a. Insert the System 9740 Operation Disk, V ersion 8.03.012, into the disk drive of the CC1. b. Copy the CM9740.EXE executable file from the 9740 directory on the Operation Disk to the C:9740 directory of the CC1.
6 C1547M (7/03) UPGRADING SYSTEM 9740 SOFTW ARE IN A MUL TI-NODE SYSTEM NOTE: Any external computer interface (such as an access control system, alarm system, fire system, building management/ control system, or VMX200) that is using the P protocol to communicate with a CM9740-CC1 running version 7.
C1547M (7/03) 7 b. Remove the current System Manager program: (1) In the Windows taskbar , click the Start button. (2) Highlight Settings and then click Control Panel .
8 C1547M (7/03) 6. Upgrade the CC1 system software executable file, CM9740.EXE: a. Insert the System 9740 Operation Disk, V ersion 8.03.012, into the disk drive of the CC1. b. Copy the CM9740.EXE executable file from the 9740 directory on the Operation Disk to the C:9740 directory of the CC1.
C1547M (7/03) 9 (b) V erify that the 9760NIU.EXE or NET9760.EXE file was renamed to 9760NIU.OLD or NET9760.OLD, respectively , by entering: dir/w (2) Insert the System 9760 Network Disk, version 8.03.012, into the disk drive of the NW1. (3) Copy the executable file, 9760NIU.
10 C1547M (7/03) APPENDIX A. UPGRADING CM9740-MXB FIRMW ARE CAUTION: Only qualified personnel observing electrostatic discharge (ESD) precautions should perform the proce- dure below . Always wear a grounding strap connected to an approved grounding source when working on or near exposed electronic components.
C1547M (7/03) 11 U5 U11 U12 PROM CHIP U12 U10 ALIGNMENT NOTCH U5 U11 U10 RAM CHIP U10 U12 Figure 3. U12 PROM Chip Figure 4. U10 RAM Chip 3. Replace the existing U12 PROM chip on the video output card with the chip supplied in the upgrade kit: a. Locate the existing U12 PROM chip on the video output card (refer to Figure 3).
12 C1547M (7/03) 5. Reinstall the video output card into slot 17 of the matrix bay (refer to Figure 2): a. Align the top and bottom edges of the card with the top and bottom card guides of the matrix bay .
C1547M (7/03) 13 APPENDIX B. CONNECTING AN ASCII COMMUNICA TIONS DEVICE TO THE CM9740-CC1 As stated previously in this manual, version 8.03.012 of CM9740-CC1 software is not compatible with version 3.
14 C1547M (7/03) CONNECTING AN ACD DB9 PORT TO A CM9740-CC1 RJ-45 PORT To connect an ACD DB9 port to a CM9740-CC1 RJ-45 port, refer to Figure 6 and do the following: 1. Connect the 9-pin side of the PV130 converter to a DB9 port of the ACD. 2. If necessary , connect a +12 VDC power supply to the PV130 converter; otherwise, proceed to step 3.
C1547M (7/03) 15 W ARRANTY AND RETURN INFORMA TION W ARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.
World Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Pelco CM9740-UPG-8312 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Pelco CM9740-UPG-8312 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Pelco CM9740-UPG-8312 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Pelco CM9740-UPG-8312 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Pelco CM9740-UPG-8312, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Pelco CM9740-UPG-8312.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Pelco CM9740-UPG-8312. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Pelco CM9740-UPG-8312 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.