Manuale d’uso / di manutenzione del prodotto 1185 del fabbricante Patton electronic
Vai alla pagina of 12
USER MANU AL MODEL 1184 & MODEL 1185 Kilolight ™ Single Fiber Modems SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www .patton.
T ABLE OF CONTENTS Section Page 1.0 W arranty Information .............................................................2 1.1 Radio and TV Interference 1.2 CE Notice 1.3 Service 2.0 General Information ..................................................
1.3 SERVICE All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container . This number may be obtained from Patton Electronics T echnical Service at (301) 975-1007 , at our web site at http://www .
Switch S1-1 through S1-4 (Model 1 184 :): Async/Sync Data Rate On Model 1 184 Switches S1-1, S1-2, S1-3 and S1-4 set two parameters: synchronous or asynchronous data rate and the maximum transmission distance between two Model 1 184s. Data Max. Distance S1-1 S1-2 S1-3 S1-4 Rate (kbps) in miles (km) On Off Off On 0-19.
Switch S1-1 through S1-4 (Model 1 185) : Async/Sync Data Rate On Model 1 185 Switches S1-1, S1-2, S1-3 and S1-4 set two parameters: synchronous or asynchronous data rate and the maximum transmission distance between two Model 1 185s. Data Max Distance S1-1 S1-2 S1-3 S1-4 Rate (kbps) in miles (km) On Off Off On 0-19.
4.0 INST ALLA TION Once the Model 1 184 or 1 185 is properly configured, it is ready to connect to the fiber interface, to the serial port, and to the power source.
Installing the New QuickConnect™ Module 1) Make sure the power switch is off. Leave the power cord plugged into a grounded outlet to keep the unit grounded. 2) Hold the module with the faceplate toward you and align the module with the guide slots in the rear panel of the Model 1 184/1 185.
5.0 OPERA TION Once the 1 184 or 1 185 is properly configured and installed, it should operate transparently . This sections describes power-up, reading the LED status monitors, and using the built-in loopback tests . 5.1 POWER-UP T o apply power to the Model 1 184/1 185, first be sure that you have read Section 4.
5.3 DIAGNOSTICS Model 1 184 and 1 185 are equipped with V .54 diagnostics that may be used to to evaluate the condition of the local and remote units, as well as the twisted pair link between them: local loopback (LAL) and remote digital loopback (DL).
APPENDIX A SPECIFICA TIONS T ransmission: Asynchronous and Synchronous Clocking: Internal, external or derived from receive signal Distance: 3 miles maximum (4.8km) 1 184 Data Rates: Asynchronous: 0 to 19.2 kbps Synchronous: 4.8, 9.6, 14.4, 19.2, 28.8, 32.
APPENDIX C V .35 Interface Pin Description M/34 Female Connector Pin # Signal B SGND (Signal Ground) C RTS (Request to Send) D CTS (Clear to Send) E DSR (Data Set Ready) F CD (Carrier Detect) H DTR (D.
APPENDIX C (cont) X.21 Interface Pin Description (DB-15 Female Connector) Pin # Signal 1 . . . . . . . . . . . . Frame Ground 2 . . . . . . . . . . . . T (T ransmit Data-A) 3 . . . . . . . . . . . . C (Control-A) 4 . . . . . . . . . . . . R (Receive Data-A) 5 .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Patton electronic 1185 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Patton electronic 1185 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Patton electronic 1185 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Patton electronic 1185 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Patton electronic 1185, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Patton electronic 1185.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Patton electronic 1185. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Patton electronic 1185 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.