USE R MAN UA L MODEL 1092 A High Speed, 2-Wire/4-Wire , Sync & Async Short Range Modem Part# 07M1092A- E Doc# 033031U D Revised 03/29/0 0 SALES OFFIC E (301)975-100 0 TECHNICAL SUPPOR T (301)975-100 7 http://ww w .
TABLE OF CONTENT S Sectio n Pag e 1. 0 Warranty Informatio n ............................................................ . 2 1. 1 Radio and TV Interferenc e 1.2. CE Notic e 1. 3 Service 2. 0 General Informatio n ......................................
1.3 SERVIC E All warranty and non-warranty repairs must be returned freigh t prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shippin g containe r . This number may be obtained from Patton Electronic s T echnical Service at : tel: (301)975-100 7 ; email: support@patton.
2.3 1092A SNMP MANAGEMENT SOLUTIONS Model 1092A is SNMP manageabl e when it is connected to a rack-mounted Model 1092ARC . SNMP management is enable d through a 1001MC rack management card located in the Patto n Electronics Rack System. 2.3.1 HTTP/HTML Managemen t The 1001MC maintains HTML pages that can be viewed through a web browse r.
7 3.1.1 Configuration DIP Switch Set “S1 ” Use the eight switches in DIP Switch Set “S1” to configure the dat a rate, asynchronous or synchronous data format, transmit clock sourc e and response to RDL request. The following table summarizes defaul t positions of DIP Switch S1.
9 Switch S1-8: Response to RD L Reques t Use Switch S1-8 to allow Model 1092A to enter the Remote Digita l Loopback diagnostic test when requested to do so by the far end Mode l 1092A For example, when Switch S1-8 is set to “ON”, it will enter RD L mode (See Section 5.
1 1 3.2 CONFIGURING THE SOFT WARE SWITCHE S The Model 1092A features a menu-driven command system tha t allows you to configure the local 1092A. Follow the instructions belo w to configure the Model 1.
1 3 MAIN MENU Option 2: Display Hardware Configuratio n Select Option 2 to display the configuration of the hardware DIP - switches. T o use the Hardware Configuration for the Activ e Configuration, select MAIN MEN U Option 5. Then select “Us e Hardware DIP-Switches”.
1 5 2. Data Forma t Select Option 2 in the SOFTWARE CONFIGUR ATIO N Menu t o select the async or sync data format (See below). 3. Clock Mod e Select Option 3 in the SOFTWARE CONFIGUR ATION Menu t o select the sync clock mode (See below) .
7. DTE Controlled Remote Digital Loo p Select Option 7 in the Menu t o enable DTE control of the Remote Digital Loop Menu (See below). Th e interface by selecting Enable (Option 1). To instruct the 1092A t o ignore this request from the DTE interface, select Disable (Option 2) .
1 9 The Model 1092A Test Modes are described on the following page. To run or terminate a particular test, key in the option to get to tha t screen menu. OF F T erminates all test s 51 1 Initiates the built-in test pattern generator and detector . 511 with Error s Initiates the built-in test pattern generator and detector.
2 1 3. Proper 2-Wir e Pairin g between the two modems is as follows : SIGNA L PIN # PIN # SIGNA L TI P 4 --------------------------------------- - 4 TI P RIN G 5 --------------------------------------- - 5 RIN G 4.
2 3 2) Hold the module with the faceplate toward you and align th e module with the guide slots in the rear panel of the Mode l 1092A. 3 ) While keeping the module’s faceplate parallel with the Mode l 1092A rear panel, slide the module straight in – so that the car d edge contacts line up with the socket inside the chassis.
2 5 4.3.2 Connecting to a DC Power Sourc e The 48 VDC power supply option uses a 3-pin terminal block wit h spring-type connectors. Please refer to the Model 1090 Series Servic e Manual . WARNING ! There are no user-serviceable parts in th e power supply section of the Model 1092A .
been placed in Test Mode. The unit can be placed in test mode by the local or remote user . N S Glow red to indicate that the local Model 1092A has not yet connected with the remote 5.3 TEST MODE S The Model 1092A offers two proprietary loopback test modes, plu s a built-in V .
5.3.3 Using the V .52 (BER) Test Pattern Generato r T o use the V .52 BER tests in conjunction with the Remote Digita l Loopback tests (or with Local Line Loopback tests), follow thes e instructions : 1. Locate the “5 11/511E” toggle switch on the front panel of the 1092A and move it U P .
APPENDIX B PA TTON ELECTRONIC S MODEL 1092A FACTORY REPLACEMEN T PART S AND ACCESSORIE S Patton Electronics Model # Descriptio n IM1/ A .............................. . V .24 with DB25 F IM1/ B .............................. . RS422/RS530 with DB25 F IM1/ C .
3 3 APPENDIX C PA TTON ELECTRONIC S MODEL 1092A INTERFACE PI N ASSIGNMEN T (Continued ) V .35 Interface (M/34F Female Connector ) (DCE Configuration ) Pin # Signa l B .......................... . SGND (Signal Ground ) C .......................... . RTS (Request to Send ) D .
APPENDIX D APPENDIX D PA TTON ELECTRONIC S MODEL 1092A CONTROL PORT PIN ASSIGNMEN T The 1092A control port is an 8 position connecto r, compliant wit h EIA/TIA-561 .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Patton electronic 1092A è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Patton electronic 1092A - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Patton electronic 1092A imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Patton electronic 1092A ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Patton electronic 1092A, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Patton electronic 1092A.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Patton electronic 1092A. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Patton electronic 1092A insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.