2 T ABLE OF CONTENTS 1.0 Warranty Information ................................................................. 4 1.1 FCC Information ........................................................................... 4 1.2 CE Notice .........................
3 A.6 G.703 Distance ........................................................................... 24 A.7 A.7 Connector ............................................................................. 24 A.8 Operating Modes/speed ..........................
4 1.0 W ARRANTY INFORMATION P atton Electronics warrants all Model 1082/F components to be free from def ects, and will—at our option—repair or replace the product should it f ail within one year from the first date of shipment.
5 1.3 SERVICE All warranty and non-w arranty repairs m ust be returned freight prepaid and insured to P atton Electronics. All retur ns must hav e a Return Mater i- als A uthorization number on the outside of the shipping container .
6 2.0 GENERAL INFORMATION Thank you f or your purchase of this P atton Electronics product. This product has been thoroughly inspected and tested and is warranted f or One Y ear par ts and labor .
7 clear channel timing (without byte integ r ity preser vation) o ver the modem link. The 1082/F is capable of handling either netw ork timing or modem timing, thereby realizing netw ork e xtension or network replacement con- figurations. Clock jitter is attenuated according to G.
8 Applications and Associated Timing There are two typical applications that result in two diff erent timing modes f or the G.703 interf ace. These are described in the following sections . Timing of Application 1: Network Loop Extension. In this application, the network supplies the timing for the entire system.
9 The first G.703 interf ace is in Network Timed mode. The second is in Recover Cloc k mode. See Figure 2. Figure 2. Network Loop Extension Configuration Timing of Application 2: Network Replacement. The first modem uses an internal timing source and supplies the timing for the entire system.
10 The first G.703 modem is in Internal Clock mode. The second modem is in Receive Recover mode. See Figure 3. Figure 3. Network Replacement Configuration 2.5 TIMING MODE SELECTIONS Based on the timing arrangements and cloc k sources mentioned abo v e, there are two timing modes in which the interf ace can work.
11 In both cases, the transmitter uses the smoothed cloc k. 2.6 OPERATING MODE SELECTIONS There are two data modes in which the interf ace passes data and timing: • Octet Mode —This mode preser ves the b yte integrity associated with Octet timing.
12 3.0 CONFIGURATION The Model 1082/F is equipped with 8 DIP s witches that enable configu- ration of the unit f or a v ariety of applications. This section describes s witch locations and e xplains the diff erent configurations .
13 Figure 5. DIP switches Figure 5 shows the orientation of the DIP s witches in the “ON” and “OFF” positions. Configuring DIP Switch S1 DIP s witch S1 is where y ou configure the units f or.
14 SW1-1 Octet Function. This s witch determines whether the modem will be set f or clear channel mode or Octet timing. The 1082/F can be used with either another 1082/F , a 1092A/F or a 1092ARC/C/OO modem from P atton. Howe v er , when used in Octet timing mode, the 1082/F must be used with another 1082/F .
15 SW1-6/7 Clock Mode. Use Switches S1-6 and S1-7 to configure the 1082 or Model 1082/144 f or internal, or receive recov er cloc k mode. Note Placing SW1-6 and SW1-7 in the OFF mode performs reset of the hardware/software .
16 4.0 INSTALLATION Once the Model 1082 has been configured, it is ready to connect to the twisted pair interf ace, to the 64K co directional interf ace , and to the power source . This section tells y ou how to mak e these connections. Figure 6. Model 1082/F Rear View 4.
17 The RJ-45 connector on the Model 1082’ s twisted pair interface is polar- ity insensitive and is wired f or a two-wire interface . The signal/pin rela- tionships are shown in Figure 7.
18 4.2 CONNECTING POWER The Model 1082 (all versions) are a v ailab le with Univ ersal A C (100– 240V A C), 120V A C , 230V AC or -48VDC pow er options. This section describes these options. Universal A C Po wer (100–240 V AC) The Model 1082 uses a 5VDC , 2A universal input 100-240V AC , power supply (center pin is +5V).
19 z W ARNING There are no user -serviceable parts in the power supply section of the Model 1082. Fuse replacement should only be performed by qualified service personnel. Contact Patton Electronics T echnical support at +1 (301) 975-1007, via our web site at www .
20 5.0 OPERATION Once the Model 1082 is properly configured and installed, it should oper- ate transparently . This sections describes power-up , reading the LED status monitors, and using the b uilt-in loopback test modes .
21 5.3 T EST MODES The Model 1082 off ers two proprietar y loopback test modes , plus a built- in V .52 BER test patter n generator , to ev aluate the condition of the modems and the communication link. These tests can be activ ated ph ys- ically from the front panel, or via the interf ace.
22 Remote Digital Loopback (RDL) The Remote Digital Loopback (RDL) test chec ks the performance of both the local and remote Model 1082s, and the communication link betw een them. Any characters sent to the remote Model 1082 in this test mode will be returned back to the originating device (see Figure 12).
23 Using the V .52 (BER) test pattern generator T o use the V .52 BER tests in conjunction with the Remote Digital Loop- back tests (or with Local Line Loopbac k tests), do the f ollowing: 1. Locate the 511/511E toggle s witch on the front panel of the Model 1082 and set the toggle to the down position.
24 APPENDIX A MODEL 1082 SPECIFICATIONS A.1 APPLICATIONS 64K G.703 co directional PCM network extension or netw ork replace- ment A.2 T RANSMISSION FORMAT Synchronous A.3 T RANSMISSION LINE Single unconditioned twisted pair A.4 CLOCKING Internal, external or receive loopback A.
25 A.10 TIMING MODES Suppor ts network timing mode or modem timing mode A.11 TRANSMIT LEVEL 2.0V diff erential, into 100 Ohms, nominal A.12 LOAD IMPEDANCE 120 Ohms A.13 INPUT SIGNAL LEVEL 0 to -10dB A.14 JITTER PERFORMANCE CTR 14, G.823. <0.05UI jitter for network e xtension applications A.
26 A.20 ALTITUDE 0–15,000 f eet (0–4,572 meters) A.21 HUMIDITY 5 to 95%, non-condensing A.22 DIMENSIONS 4.125W x 1.625H x 6.0D in. (10.5W x 4.1W x 15.
27 APPENDIX B MODEL 1082 F ACTOR Y REPLACEMENT PARTS AND ACCESSOR IES Model # Description 48V -PSM DC P ower Supply Module 08055DCUI 100-240V A C (+5V ±5% reg.
28 Notes _________________________________________________________ _________________________________________________________ _________________________________________________________ _________________.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Patton electronic 1082/F è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Patton electronic 1082/F - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Patton electronic 1082/F imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Patton electronic 1082/F ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Patton electronic 1082/F, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Patton electronic 1082/F.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Patton electronic 1082/F. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Patton electronic 1082/F insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.