USER MANUAL MODEL 1080A and MODEL 1080A-64 Universal Synchronous & Asynchronous Short Range Modems SALES OFFICE (301) 975-1000 TECHNICAL SUPPO R T (301) 975-1007 http://ww w .
1.0 W ARRANTY INFORMA TION Patton Electronics warrants all Model 1080A Series components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment.
2.0 GENERAL INFORMA TION Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected by Patton's qualified technicians. If any questions or problems arise during installation or use of this product, please do not hesitate to contact Patton Electronics T echnical Support at (301) 975-1007.
Each Model 1080A Series SRM has three sets of eight switches, yielding 24 total DIP switches. The three sets will be referred to as S1, S2 and S3. As Figure 2 shows, the orientation of all DIP switches is the same with respect to “ON” and “OFF” positions.
Switch S1-8: Carrier Control Method The setting for switch S1-8 determines whether the carrier is “constantly on” or “controlled by RTS”. This setting allows for operation in switched carrier , multipoint and/or hardware handshaking applications.
3.4 CONFIGURA TION SWITCH SET “S3” The DIP switches on S3 set the anti-stream control, local loopback enable, remote loopback enable and receive (input) impedance levels for the Model 1080A Series. Factory default positions of Switch S3 are shown in the table below .
Switch S3-6: RS-232 Initiation of Remote Loopback T est The setting for switch S3-6 determines whether or not the Model 1080A Series’ remote digital loopback test can be initiated by raising pin 21 on the RS-232 interface.
4.1.1 T wo-Wire Cable Connection Via RJ-45 A. The RJ-45 jack on a Model 1080A Series Short Range Modem is prewired for a standard TELCO wiring environment.
4.2.1 Four-Wire Cable Connection Via RJ-45 A. The RJ-45 jack on a Model 1080A/1080A-64 Short Range Modem is prewired for a standard TELCO wiring environment.
4.3 FOUR-WIRE, MUL TIPOINT INST ALLA TION Multipoint operation involves the connection of several terminals to one host port. In such an application, one local Model 1080A/1080A-64 is used as a master unit, and it is connected to several remote Model 1080A/1080A-64s that are acting as slaves.
5.1.4 The “Error” Indicators The “Error” indicator LED has three functions: A. When the 1080A Series unit is in test mode (green “T est” LED is lit), the error LED glows red when bit errors occur . B. When not in test mode (green “T est” LED is off), the error LED is used to indicate an RTS streaming condition.
5.1.4.2 Reading The T est A. If line quality is good, “Error” LED on local modem will not light and “CD” LED will be red. On remote modem “Error” LED will not light and “CD” LED will light green.
A. Activate RDL. This may be done in two ways: First, by moving the front panel toggle switch UP to "Remote". Second, by raising pin 21 on the RS-232 interface (Note: Make sure DIP switch S3-6 is ON; and DIP switch S2-6 is OFF). B. Perform a BER (bit error rate) test on the system.
APPENDIX B P A TT ON MODEL 1080A SERIES F ACT OR Y REPLACEMENT P ARTS AND ACCESSORIES Patton Model # Description 080510ACB .....................120V W all Mount AC Adapter 08059ACI ........................230V AC Adapter (No Power Cord) 07M1080A .....
APPENDIX C P A TT ON MODEL 1080A SERIES INTERF ACE PIN ASSIGNMENT RS-232 FEMALE, D-SUB 25 CONNECTOR (DCE ORIENT A TION) 1- (FG) Frame Ground 2- (TD) T ransmit Data T o 1080A 3- (RD) Receive Data From .
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Patton electronic 1080A-64 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Patton electronic 1080A-64 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Patton electronic 1080A-64 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Patton electronic 1080A-64 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Patton electronic 1080A-64, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Patton electronic 1080A-64.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Patton electronic 1080A-64. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Patton electronic 1080A-64 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.