D I R ECT VE NT/ S EALED COMBUST I ON D I R ECT VE NT/ S EALED COMBUST I ON D I R ECT VE NT/ S EALED COMBUST I ON D I R ECT VE NT/ S EALED COMBUST I ON D I R ECT VE NT/ S EALED COMBUST I ON D I R ECT VE NT/ S EALED COMBUST I ON D I R ECT VE NT/ S EALED COMBUST I ON D I R ECT VE NT/ S EALED COMBUST I ON D I R ECT VE NT/ Patterson-Kelley P .
The rm ifi c ® Gas-Fired Boiler Table of Contents 1.0 INTRODUCTION ..................................1 1.1 Code C ompli ance................................ 1 1.1.1 Direct Vent/Sealed Combustion Sy stem .............................................. 1 1.
The rm ifi c ® Gas-Fire d Boiler Introduction Page 1 1.0 INTRODUCTION Direct vent (ANSI Z21.13) is a closed system m ethod of ducting the combustion air di rectly from the outsi de of the bu ilding into the inlet com partm ent of the burner, an d a sealed e xhaust v ent from the combustion chamber to the outdoor s.
Thermific ® Gas-Fired Boiler Introduction/Sa fety Page 2 Exhaust V ent Air Inlet Sidewall 2. Both the com bustion air inle t and flue g as exhaust through the s i dewall. Exhaust V ent Air Inlet Roof 3. The com bustion air inlet from the roof and the flue gas exhaust t hrough the roof.
Thermific ® Gas-Fired Boile r Installation Page 3 Do not manifo ld two (2) or m ore units into a com mon sidewall v ent system withou t provis ions for additiona l forced d raft.
Thermific ® Gas-Fired Boile r Installation Page 4 Whichev er mater ial is use d, the term ination must po int down and must be backed by a metal p late secured to the wall. Importan t: The chosen in let termination m ust be included in the calculation of t he maxim u m allowab l e equivalent length.
Thermific ® Gas-Fired Boile r Installation Page 5 with the appl ication of heat. Re fer to the manufactu rer's instru ctions. W rap the joint w ith aluminum tape which is backed w ith an ad hesive on the contact side.
Thermific ® Gas-Fired Boile r Installation Page 6 3.3.3 Exhaust Vent Connection at the Boiler 6' Min. Pitch toward boiler 1/4" per foot min.
Thermific ® Gas-Fired Boile r Installation Page 7 Whichev er termina tion is chosen, it must be double wall vent ce rtified under UL 1738, or ULC-636. When insta l ling a sid ewall ex haust sy stem the termina tion must be ba cked by a metal pl ate secured to the wall as shown in th e figure.
Thermific ® Gas-Fired Boile r Installation Page 8 If the air inle t and/or exhaust v ent terminal ar e through the sidew all, clea rances from othe r exhaust/inlet, windows, doors, building openings, snow line, etc must be as s hown in the figure ab ove.
Thermific ® Gas-Fired Boile r Installation/Operation Page 9 3.4.3.2 Se ries 15 00, 170 0, 2000 Air Inlet Exhaust V ent Round Damper 90 Elbow o T ransitio n Duct 27" Min. * 31" * 24" 44" Min. * To D r a i n Boot T ee/ 135 T ee o * Dimension s hown above is ba sed on 12" round duc t wor k.
Thermific ® Gas-Fired Boile r Operation/Maintenance Pa ge 10 When the chart is com pleted, set up your boiler' s combustion to the correspondi ng information a t the temperatu re relative during the time of the start up. Enter your 100 º F operationa l range.
Thermific ® Gas-Fir ed Boiler Wiring Diagrams Pa ge 11 6.0 WIRING DI AGRAMS 6.1 O N -O FF S ERIES 700, 1000, 1200 Wiring Dia gram.
Thermific ® Gas-Fir ed Boiler Wiring Diagrams Pa ge 12 6.1 O N -O FF S ERIES 700, 1000, 1200 Logic Diagram.
Thermific ® Gas-Fir ed Boiler Wiring Diagrams Pa ge 13 6.1 A O N -O FF IR I S ERIES 700, 1000, 1200 Wiring Dia gram.
Thermific ® Gas-Fir ed Boiler Wiring Diagrams Pa ge 14 6.1 A O N -O FF IR I S ERIES 700, 1000, 1200 Logic Diagram.
Thermific ® Gas-Fir ed Boiler Wiring Diagrams Pa ge 15 6.1 B L O -H I L O Wiring Dia gram.
Thermific ® Gas-Fir ed Boiler Wiring Diagrams Pa ge 16 6.1 B L O -H I L O Logic Diagram.
Thermific ® Gas-Fir ed Boiler Wiring Diagrams Pa ge 17 6.1 C L O -H I -L O IR I Wiring Dia gram.
Thermific ® Gas-Fir ed Boiler Wiring Diagrams Pa ge 18 6.1 C L O -H I -L O IR I Logic Diagram.
Thermific ® Gas-Fir ed Boiler Wiring Diagrams Pa ge 19 6.1 D O N -O FF S ERIES 1500, 1700, 2000 Wiring Dia gram.
Thermific ® Gas-Fir ed Boiler Wiring Diagrams Pa ge 20 6.1 D O N -O FF S ERIES 1500, 1700, 2000 Logic Diagram.
Thermific ® Gas-Fir ed Boiler Wiring Diagrams Pa ge 21 6.1 E O N -O FF IR I S ERIES 1500, 1700, 2000 Wiring Dia gram.
Thermific ® Gas-Fir ed Boiler Wiring Diagrams Pa ge 22 6.1 E O N -O FF IR I S ERIES 1500, 1700, 2000 Logic Diagram.
Thermific ® Gas-Fir ed Boiler Wiring Diagrams Pa ge 23 6.2 A UXILIARY C ONTROL P ANEL 6.2.1 On- Off Au xiliary C ontrol P anel.
Pa g e 2 4.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Patterson-Kelley DVSCM-02 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Patterson-Kelley DVSCM-02 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Patterson-Kelley DVSCM-02 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Patterson-Kelley DVSCM-02 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Patterson-Kelley DVSCM-02, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Patterson-Kelley DVSCM-02.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Patterson-Kelley DVSCM-02. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Patterson-Kelley DVSCM-02 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.