Manuale d’uso / di manutenzione del prodotto SLV 9128 del fabbricante Paradyne
Vai alla pagina of 32
1 Fram e Saver ® SL V 9128/9128- II Netwo rk Access Module (NAM ) Ins tallat i on Inst r uct ions Document Number 9128-A2-GN 11-50 April 20 02 Product Doc ume ntati on Online Complet e documen tat ion f or this pr oduct is av ail abl e a t w w w . pa ra dy n e.
2 Pa c ka g e Ch ec k li s t V er if y that y our pac kage contai ns t he fo llo wing: ❑ F rameSav er SL V NAM ❑ NAM I/O card ❑ T1 net work c able ❑ F rameSav er SL V 9 128/ 9128-I I Quic k Ref erenc e (Documen t No . 9128- A2- GL10) Be sure to r egi ster y our war ranty at www .
3 Cabl es Y o u May N eed t o O rde r Contac t your sales repr ese ntati v e t o order cab le s. Safet y Inst ruction s Pleas e read the Impor tant Sa f ety Inst ructions on page 27.
4 Instal ling the I/O Card The NAM ’ s I/O card pr ov ides the net wo r k , DSX, DBM, mode m, DTE, and COM port connect io ns. T he I/O c ard inse r ts dire ctly beh ind the NAM that it supports in the access carrier . Pr ocedur e 1. Remo v e th e I/ O ca rd fr om the sh ipping bo x.
5 Ins tall ing th e NAM into a Multi slo t Hou sing The i llu strat ion shows the 14 - slot a cces s car r ier h ousing. CA UT ION: Be sure that y ou instal l the NAM in the cor re ct slot so that it mates w it h it s matchi ng I/O card. Otherwise, y ou coul d damage y our car d.
6 Connecting the COM P ort to an Asynchr onous T erminal A VT100 - compatib le a synchronous terminal or a PC pr ovid ing VT10 0 terminal em ula tion mus t be used to set up acc ess t o and management of the unit.
7 A Quic k G uide t o Co nf iguratio n The F rameSa v e r uni t shou ld oper ate using the def ault (f ac tory-set ) conf i gurat ion opti ons, wi th e xception to t he chang es specified in th ese i nstall at ion ins truc tions . Refer to the f ollowi ng ta ble f or help in nav igating th e menus .
8 About the Installati on Procedures There are t wo methods f or i nstal ling and se tti ng up t he F rameSa v er un it. One person can i nstal l an d set up the u nit.
9 It i s assume d that fr am e rel a y ser vice i s turned on at the site . Pr ocedur e 1. Selec t the Easy Instal l f eature . Main Me nu → Easy Inst all 2. Enter the Node IP Add ress a nd Subnet Mas k. 3. Set TS Access t o DLCI, then select a DLCI on the netw ork interf ace t h at will be used f o r the trou b les hooti ng a ccess link.
10 11. Set u p SNMP l ocal manageme nt (see Sett ing Up Local Managemen t at the Central Sit e on pa ge 13). 12. Set up the modem, and the Cal l Directo ries if trap dia l-out is des ir ed (see Sett ing Up the Modem on pa ge 14). 13. I f the un it is equipped with an I SDN DBM, set up t he DBM (see Sett i ng U p th e ISD N DBM on page 16).
11 Minimal Inst allat ion fo r Ser vi ce Pr ovi ders In the f ollowi ng pro cedures , once the uni t is inst alled and mini mal confi gur atio n is com ple ted using the Easy I nstal l f eat u re, the NOC can comp le te and verif y the setup .
12 Completi ng Setup of the Unit From the NOC Pr ocedur e 1. Access t he remot e F rameSa v er uni t us ing t he dedi cated manag ement l ink, us i ng the Node IP Addr ess that was ent ered (se e Ph ysically Ins tall in g t he Uni t and Se ttin g U p for Re mote Acce ss on pa ge 11).
13 Setting Up Local Managem e nt at the Cen tral Site Pr ocedur e 1. Creat e a DLCI f or the dat a port. Confi gurat ion → Da ta P or t s → DLCI Records 2. S av e the confi gurat ion. 3. Creat e a M anagement PVC usi ng t he d ata po r t DLCI just c reated.
14 A ut oma tic Co nfigur a t ion The F rameSa v e r uni t pr ovide s s e vera l automat ic configur ati on fe atures . F rame Rela y Disco ve r y and configur at ion is one of the se fea tures . Main M e nu → A ut o-Confi gur ati on The de fault dis cov ery mode i s 1M P or t.
15 Setti ng Up C all D irector ies if T rap Dial-O ut Is D esired Pr ocedur e 1. Set up dir ect ory p hone nu m bers . Main Me nu → Control → Modem Call Directories 2.
16 Setting Up the ISDN DBM F rameSav er SL V 9128s and 9128-II s ma y be equi pped wi th an ISDN PRI DBM. These inst ructions ar e for units with ISDN bac kup cap abili t y . The f oll owing gui del ines appl y: Centra l site confi gurat ion guid el ines: — Set up the ISDN DBM phys ical i nte rf ace .
17 Modi fying IS DN L ink Profiles Pr ocedur e 1. Selec t Link Profi les, then M odify . The F rameSav e r uni t automat ic ally con fi gur es an ISDN Link Profi le on the firs t ISDN l ink, with HQ_Si te a s the Link Name . F or s ubsequent ISDN L ink Pr ofiles , sel ec t N ew.
18 Conf iguring S NMP T rap Mana ger s and T rap Dial -Out Onc e the F rameSa ver unit is connect ed to the net work, SNMP tra p manager s, SNMP tr aps, and t rap dial-out c an be conf igure d. Pr ocedur e 1. Selec t SNMP T raps. Main Me nu → Configu ra tion → Management and Com m uni cati on → SNMP T rap s 2.
19 Connect ing to a n M 66 Block Use t he optional T1 mass t erm inati on cabl e to connect up t o sev en NAM s t o an M 66 bl ock. The T1 mas s termination cabl e i s a 5- f oot RJ4 8H cable consi sting of a 50-pi n plug- to-s e v en RJ48 C plugs. Pr ocedur e 1.
20 V er ify ing th e En d-t o-E n d Path Afte r install at ion of a remot e si te unit, run an I P Ping t est to ping the NMS at the cent ral sit e an d verify t hat th e enti re p ath fr om t he remot e unit to the NM S i s funct ioni ng. T o run the IP Pi ng tes t, NMS trap mana gers m ust ha v e be en conf igure d f or t he re mote unit.
21 Connecting t o ISDN Pr ocedur e 1. Insert the 8-pi n connecto r on the ISD N ca bl e in to th e DBM int erf ace. 2. Insert the other e nd of the cab l e int o the ISDN se r vice RJ48 C jack . Connecting the Modem Pr ocedur e 1. Insert the 6-pi n connecto r on the modem cab l e into t he MDM in ter f ace .
22 Conn ectin g to Et hernet Pr ocedur e 1. Insert one 8- pin co nnector of the Et hernet c able int o the Ethernet port. 2. Insert the other end of t he cab le int o the Et hernet interf ace of the LAN where the NMS resides. Connectin g to a DTE Pr ocedur e 1.
23 V erifying Connecti o ns and Setup Chec k the modem, DSX, E thernet, DTE, a nd PVC co nnecti ons, as we ll as the ISDN DBM setup if a DBM is instal led. Che cki n g th e Mod em Co nn ect ion Pr ocedur e If P or t Use is set to T er m in a l (d ia l- in ac c e ss): 1.
24 Checki ng the DTE Connec tion P erf or m the se chec k s f or both user data ports. Pr ocedur e 1. V e rif y that the P or t OK LED i s on . If not , m a ke sure bo th ends of the cab le are properl y seated and secur ed. Th en, che c k t he DTE; R TS or DTR coul d be do wn o n the DTE.
25 Checking PVC Conn ections Chec k PVC connecti ons to ve rify that al l PVCs , includi ng managemen t PVCs , are confi gu red, and to se e whe ther the PVC is activ e or not. Pr ocedur e 1. Press Esc t o return to the St atus menu . 2. Selec t PVC Connect ion Stat us .
26 V e rif yi n g the ISDN Line and That Data Can B e Pass ed Between DBMs Pr ocedur e 1. V erif y the I SDN li ne by chec ki ng the DBM Interf ace Status. Main Me nu → Status → DBM Interf ace Statu s Line Statu s shoul d be Act ive . If an in val id ( Inv) st atus is displa y ed, veri fy that y ou enter ed ISDN phy sical opti ons correct ly .
27 Impo rtant Safet y Inst ructi o ns 1. Read a nd fol low all warning noti ces an d inst ructions mark ed on the p rodu ct or incl uded i n th e man ual. 2. If inst alled i n a c ar rier wi th a n AC power supply , thi s prod uct i s i ntended to be used with a 3-wir e gr ounding type plug – a plug which has a groun ding p in.
28 7. Gene ral purpose ca bles ar e provide d wit h thi s prod uct. A UL Li sted/CSA Ce rt ified , mini mum No . 26 A WG, telec ommuni cati ons cab le is provi ded fo r connect ion to the netw ork.
29 EMI Notices UNI TED S T A TES – EM I NO TICE: ! This equi pment has been test ed and f ound to comply with the limits f o r a Class A digi ta l devic e, pur suant to P art 15 of the FCC rules.
30 If y our uni t caus es harm to the t elephone net work, t he tel epho ne company ma y disc ontin ue your ser vice temporari l y . If p ossib le, they will not ify y ou in adv ance. But if adv ance no ti ce is not prac tical , you will be not ifi ed as soon as pos sibl e.
31 Ca nada Notice to Users of th e Canadia n T eleph on e Network The I ndus try Canada l abel identi fies c ert ifie d equi pment. This c er tifi cation m eans t hat the equi pment me ets t el ecommu.
32 W arranty , Sales, Service, and T raining Inf orm a tion Contac t your local sa les represen tati v e , service rep resent ativ e , or dis trib ut or dire ctl y f or any hel p need ed.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Paradyne SLV 9128 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Paradyne SLV 9128 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Paradyne SLV 9128 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Paradyne SLV 9128 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Paradyne SLV 9128, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Paradyne SLV 9128.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Paradyne SLV 9128. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Paradyne SLV 9128 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.