Manuale d’uso / di manutenzione del prodotto KX-TDA100 del fabbricante Panasonic
Vai alla pagina of 194
KX-TD A100 Model KX-TD A200 Thank you f or purchasing a P anasonic Hybr id IP-PBX. Please read this manual carefully bef ore using this product and sav e this manual f or future use. KX-TD A100/KX-TD A200: PMPR Software File V ersion 3.0000 or later Hybrid IP-PBX Installation Manual SD Logo is a trademark.
2 Installation Manual System Components System Components T able Category Model No. Description Shelves K X-TDA100 Basic Shelf KX-TDA200 Basic Shel f Main Processing Card Main Pr ocessi ng Card (M PR).
Installation Manual 3 A vailable Pr oprietary T elephones The Hy brid IP-PBX supp or ts all of th e P a nasoni c KX- T7000, K X-TD70 00, and KX-NT se r ies: • Digital/A nalog /IP propr ieta r y tel ephone s (e.g., KX-T 7625, K X-T7630, KX-T7 633, KX -T763 6, KX- NT136) • P or table statio ns (e.
4 Installation Manual Impor tant Noti ce Pr ior to c onnectio n of this produc t, ple ase verif y that the i ntende d operating environment i s su ppor ted.
Installation Manual 5 Impor tant Safety Instructions SAFETY REQUIREMENTS When us ing your tel ephone equi pment, basic s afety precautions should a lwa y s be follow e d to r educe the ri sk of fir e, electr ic shock and in jur y t o person s, inclu ding th e following: 1.
6 Installation Manual SA VE THESE INSTR UCTIONS.
Installation Manual 7 Precaution W ARNING DO NO T REMO VE SD MEMOR Y CARD WHILE PO WER IS SUPPLIED T O THE HYBRID . IP-PBX Doing so ma y cause the Hybrid IP-PBX to fail to star t when y ou tr y to restar t the system.
8 Installation Manual • K ee p the un it awa y fro m heati ng applia nces and devices that ge nerate el ectr ical no ise suc h as fluores cent la mps, motors an d televisions. These no ise sour ces can inter f e re with th e performa nce of the Hybr id IP-PBX .
Installation Manual 9 P assw ord Securit y W arning to the Administrator or Installer regarding the system pass wor d 1. Please provide all syste m pa ss wor ds to the custo mer .
10 Installation Manual When y ou sh ip the pr oduct Careful ly pack and send it pr epai d, adequ ately in sure d and preferably in the or ig inal car ton. A ttach a postage -paid le tter , d etailing the symp tom, to th e outs ide of the car ton. DO NO T s end the pr oduct to the Executiv e or Re gional S ales o ffice s.
Installation Manual 11 Intr oduction This Ins talla tion Ma nual is des igned to ser v e as an overall technic al re f e rence for the Panasonic Hyb r id IP- PBX, K X-TDA100/KX-TDA200. It provides instr ucti ons for installi ng the h ardware, and p rogramming t he Hybr id IP- PBX using the KX -TD A Maint enance Conso le.
12 Installation Manual F .C.C. REQUIREMENTS AND RELEV ANT INFORMA TION 1. Notification to the T elephone Company This equ ipmen t complies with P ar t 68 of the FCC r ule s and the req uiremen ts adopt ed by the ACT A.
Installation Manual 13 If your home ha s speci ally wire d alar m e quipm ent con necte d to the telepho ne line, ensu re the installa tion of thi s equipmen t does not di sable your alarm equipme nt. If you ha ve questions about what will disable ala r m eq uipme nt, consu lt your teleph one co mpany or a q ualifi ed inst alle r .
14 Installation Manual For Cell Station CA UTION Any changes or modi ficat ions not expressl y app rov ed by the par ty res ponsible for complianc e cou ld v o id use r's autho r ity to ope rate this device.
Installation Manual 15 T ab le of Contents 1 Syst em O utline ... ..... .... ..... ..... ..... ..... .... ........ .... ..... ..... ..... ..... .... ..... ..... ... 19 1.1 Syste m H ig hligh ts . ..... .... ..... .... .... ..... .... ..... ...... ....
16 Installation Manual 2.5.5 SLC8 Card (KX-TD A0173) ..... . ........ ............. . ....... .............. ............... .............. ............. . .... 96 2.5.6 EXT -CID Card (KX-TD A0168) ......... ............. ........... . ....... .......
Installation Manual 17 5.1 Revisio n His to ry. .... ..... .... ..... .... .... ..... .... ..... .... .... ....... .... ..... .... ..... .... ..... .... .... ..... .... ..... ... 186 5.1 .1 PMPR S oftwa re Fi le V ersion 1.1 xx x ... .... ..... .... .
18 Installation Manual.
Installation Manual 19 Section 1 System Outline This sec tion p rovides general informati on on the Hyb rid I P- PBX, includi ng the syst em cap acity an d spec ificati ons.
1.1 System Highlights 20 Installation Manual 1.1 System Highlights 1.1.1 System Highlights Netw or king Features The Hy bri d IP-PBX s uppor ts the following pr ivate networ king features : TIE Line Service PBXs c an be con nected via p rivately leased t ele phone lin es for ming a private ne twork .
1.1 Syste m Highlights Installation Manual 21 Third- Party CTI A pplications The Hybr id IP- PBX sup por ts ind ustr y standa rd protoco ls, allowing thi rd-par ty CTI a pplicati ons to be integrated with the PB X and its extensions.
1.2 Basic Sy stem Construction 22 Installation Manual 1.2 Basic System Const ruction 1.2.1 Basic Shelf The bas ic shel f contains an MPR ca rd for controll ing the H ybr id IP- PBX. T o use the system, i nstal l a power supply unit (PSU ) in the P SU Sl ot and optiona l ser vice ca rds in the b asic s helf.
1.2 Basic Sy stem Construction Installation Manual 23 1.2.2 System C onnection Diagram Doorphone & Door Opener BGM/Music On Hold (MOH) Pager/ Speaker Voice Processing System KX-T7636/ KX-T7633 Rem.
1.2 Basic Sy stem Construction 24 Installation Manual PS PC Radio Amplifier Pager/Speaker Doorphone & Door Opener SLT Wireless Phone Fax Machine Hybrid IP-PBX LAN Private IP Network Station Messag.
1.3 Optiona l Equipment Installation Manual 25 1.3 Optional Equipment 1.3. 1 Optio nal Equipme nt Model No. Model Name Description KX-TDA0103 L-T yp e P ower Supply Unit (PSU -L ) P ower Supply Uni t f o r KX-TDA200. T otal power output of 279 W . Safety Class 1 compli ant.
1.3 Option al Equipment 26 Installation Manual Note F or the maximum number of o ptional se r vic e cards that can b e insta lled in the Hybri d IP-PBX, r efer to "1.4.3 Syst em Capaci ty". KX-TDA0181 16-P or t Analog T r unk Card (LCO T16) 16-por t analo g CO line card wi th 4 power failure transfer (PFT) ports.
1.4 Specific ations Installation Manual 27 1.4 Speci fications 1.4.1 Gen eral Description Control Bus Or igin al bus (16- bit, 8 M Hz, 10 megabytes p er s econd) Communic a tion Bus H.100 bus confor mity (1 024 time slot s) Switching Non-blocking P ower Input PSU-S 100 V AC to 130 V AC , 1.
1.4 Specific ations 28 Installation Manual Extension Connection Cable SL T 1-pair wire (T , R ) DPT 1-pair wire (D1, D2) or 2-pair wire ( T , R , D1, D2) APT 2-pair wir e (T , R , D1, D2) PT -interfac.
1.4 Specific ations Installation Manual 29 1.4.2 Characteristics T erminal Equipment Loop Limit • PT: KX-T7600 ser ies DPT: 90 Ω ; all othe r DPTs /APTs : 40 Ω • SL T: 600 Ω includi ng set .
1.4 Specific ations 30 Installation Manual 1.4.3 System Capacity Maxim um Optional Service Car ds Ther e are 2 ty pes of opt ion al ser vice ca rds for insta llation: • Cards i nstalle d in the slot.
1.4 Specific ations Installation Manual 31 The following numb er of opti onal s er vi ce car ds ca n be in stall ed in the var ious s lots of the Hy bri d IP-PB X.
1.4 Specific ations 32 Installation Manual Cards Mounted on Other Opt i onal Service Car ds The following number of option al ser vic e cards can b e mounte d on the spec ified oth er opti onal ser vi ce cards . Maxim um T erminal Equipment The following number of items of ter mi nal equip ment c an be s uppor ted by the Hybr id I P-PBX.
1.4 Specific ations Installation Manual 33 MEC Car d Calculation Calcul ate the M EC figure fro m the type a nd total number of ite ms of e quipment to be con nected. If th e MEC figure e xc eeds 6 4 (for KX-TD A 100) or 128 ( f o r KX-TDA200), you need to instal l an M EC card .
1.4 Specific ations 34 Installation Manual P o w er Supply Unit Selection Hybr id IP- PBX nee ds a power supp ly unit ( PSU) s uitable for its confi guration. Ca lculate t he load figure f rom the type and numbe r of item s of eq uipmen t to be c onnected , and de ter mine the typ e of PS U that will be requ ired.
1.4 Specific ations Installation Manual 35 Calculation Exampl e (KX-TD A200) The tota l load fi gure is 96. As this is be tween 6 4 and 128, you s hould install the PSU- M. Howe ver , if you expect e x pansion in the f uture, it m a y b e better to in stall the PSU- L.
1.4 Specific ations 36 Installation Manual.
Installation Manual 37 Section 2 Installation Thi s secti on desc r ibes the pr ocedure s to i nstall the Hyb r id IP - PBX. Deta iled i nstr ucti ons for planning the in stallati on si te, insta lling th e shel v e s and option al s er vic e cards, a nd cabling of per ipheral e quipme nt are pr ovided.
2.1 Bef ore Installation 38 Installation Manual 2.1 Bef ore Inst allation 2.1.1 Before Installation Pleas e read the f ol lowing notes co ncer ning inst allati on and co nnecti on before installi ng the Hy brid IP-PBX and t er minal equipmen t. Be sur e to comp ly wi th all app lica ble laws, regulatio ns, and guidel ines.
2.1 Bef ore Installation Installation Manual 39 3. A void using the sa me AC outlet for compu ters, telex es, and other offi ce eq uipmen t, as n oise generated by such equip ment may hamper system perform ance or inter rup t the sy stem. 4. Use 2-pai r teleph one ca bles when conn ecting P Ts.
2.2 Install ation of the Hybrid IP-PBX 40 Installation Manual 2.2 Insta llation of the Hybrid IP-PBX 2.2.1 Unpac kin g Unpack the box and check the i tems b elow: KX-TDA100 KX-TDA200 Main Unit 1 1 Met.
2.2 Inst allation of the Hybrid IP-PBX Installation Manual 41 2.2.2 Names a nd Location s Inside V iew A. R UN Ind icator B. ALARM Indic ator C. USB P or t D. RS-232C P or t E. PSU Sl ot F. Null Slot (not available f or any option al ser vice car d) G.
2.2 Install ation of the Hybrid IP-PBX 42 Installation Manual 2.2.3 Opening/Clo sing the Front Co ver Opening the Front Co ver 1. Inser t a flathe ad screwdr iver into th e opening (on th e left of the screw cover) and unla tch the screw cover . 2. T ur n the s crew counterclockwise to loosen .
2.2 Inst allation of the Hybrid IP-PBX Installation Manual 43 Closing the Front Co ver 1. Hook the fr ont cover onto the she lf (lin e up the protr usi ons on the cover with the rec eptacle s on th e shelf). Then s lide the front cov er to the left un til it locks.
2.2 Install ation of the Hybrid IP-PBX 44 Installation Manual 2.2.4 Insta lling/Replacing the P ower Suppl y Unit Function Accessories and User -supplied Items Accessories (included): S c rews × 4, AC p ower co rd × 1 User-supplied (not incl ude d): Groundin g wire Note F or d etails ab out frame ground con nection, refer to "2.
2.2 Inst allation of the Hybrid IP-PBX Installation Manual 45 4. T o pro tect the ba ck board from s tatic el ectr icity , do not tou ch par ts o n the ba ck board in the m ain unit and P SU . T o di scharg e stati c elec tric ity , touch ground or wear a gro unding strap .
2.2 Install ation of the Hybrid IP-PBX 46 Installation Manual 3. T ur n the 4 screws clockwise, in the order indi cated by the numb ers 1 to 4, to fix th e PSU. Replacing the P ower Suppl y Unit 1. Unplug the AC po wer cord. 2. T ur n the 4 screws counterc lockwise to loos en the m.
2.2 Inst allation of the Hybrid IP-PBX Installation Manual 47 3. Pull the re lease lev er in the dir ection of the ar row to disc onnect th e PSU from the ba ck board. 4. Replace th e PSU . 5. F ol low the ste ps in "Inst allin g the P ower Suppl y Unit".
2.2 Install ation of the Hybrid IP-PBX 48 Installation Manual 2.2.5 Frame Ground Connection IMPOR T ANT Connect the frame of th e Hybrid IP-PBX to gr ound.
2.2 Inst allation of the Hybrid IP-PBX Installation Manual 49 2.2.6 Install ing/Removing the Optiona l Service Cards CA UTION T o prote ct the back boar d from s tatic ele ctri city , do not touch p ar ts on the back board in th e main unit and on t he optiona l ser v ice ca rds.
2.2 Install ation of the Hybrid IP-PBX 50 Installation Manual 2. Holding th e card a s shown be low , push the rel ease lev er in the direc tion o f the arr ow so that th e card engage s securel y with the co nnecto r on the b ack board. 3. T ur n the 2 screws clockwise to fix the c ard in plac e.
2.2 Inst allation of the Hybrid IP-PBX Installation Manual 51 Cover ing the Blank Sl ots Be sur e to cover each slo t in whi ch no opti onal ser vi ce car d is ins talled by usi ng a B lank Sl ot Cover . CA UTION F ailure to insta ll the Bl ank S lot Cover ma y ca use el ectroma gnetic i nterference.
2.2 Install ation of the Hybrid IP-PBX 52 Installation Manual Handling of the Cables When c ables are co nnecte d to the Hybr id IP-P BX, r un the cables to ei ther the r ight or the left an d then towards the back of the s helf as sh own below . Note F or safety reasons, do n ot stretch, b end, or pinch t he AC pow e r co rd.
2.2 Inst allation of the Hybrid IP-PBX Installation Manual 53 Remo vi ng the Op tional Servi ce Cards 1. T ur n the 2 s crews counter clockwise to loos en them. 2. Pull the releas e lev e r in th e dire ction o f the arrow to discon nect t he ca rd from the b ack board.
2.2 Install ation of the Hybrid IP-PBX 54 Installation Manual 2.2.7 T ypes of Connectors Connector T ype Pin Number Used f or (T wist ed pair cab le) • DHLC8 (KX-TD A01 70) • SLC8 (K X-TDA0173) .
2.2 Inst allation of the Hybrid IP-PBX Installation Manual 55 • IP-GW4 ( KX-T D A04 80) •B a s i c S h e l f •M P R •M P R Connector T ype Pin Number Used f or RS-232C 9 5 6 1 USB 2 1 3 4 Mini.
2.2 Install ation of the Hybrid IP-PBX 56 Installation Manual 2.2.8 Attaching a Ferrite Core A ferrite core must be atta ched wh en: • connec ting IP-G W16 and IP-E XT16 c ards usin g an RJ 45 connec tor , or • connec ting extension c ards us ing an Amphe nol conn ector.
2.2 Inst allation of the Hybrid IP-PBX Installation Manual 57 If you need to o pen the f e rri te core, us e a flat head scr ewdriver to unlat ch the case of the ferrit e core.
2.2 Install ation of the Hybrid IP-PBX 58 Installation Manual 2.2.9 Fastening Ampheno l Conne ctor An Amp henol 5 7JE-ty pe co nnector i s used on som e of the optional s er vi ce car ds.
2.2 Inst allation of the Hybrid IP-PBX Installation Manual 59 Amphenol Connector Pin Assignm ent Chart Below is an Amph enol co nnecto r pin assi gnment char t f or all optiona l ser vi ce card s that use th e Amphen ol connec tor . For more detail s, ref er to the app ropr iate sec tion in " 2.
2.2 Install ation of the Hybrid IP-PBX 60 Installation Manual 2.2.10 W all Mounting (KX-TD A200) CA UTION • Make sure that t he wall the shelf will b e attac hed to is capable of suppor ting at lea st 4 times the weight of the sh elf. • Dri ve mounting screws i nto the wall.
2.2 Inst allation of the Hybrid IP-PBX Installation Manual 61 2. Hook the sh elf ont o the met al bracket, making sure th at the shel f slides down and ont o the hoo ked par ts of the metal brack e t. Use 2 s crews (B) to fix both s ides of th e shelf.
2.2 Install ation of the Hybrid IP-PBX 62 Installation Manual 2.2.11 W all Mounting (KX-TD A100) CA UTION • Make sure that t he wall the shelf will b e attac hed to is capable of suppor ting at lea st 4 times the weight of the sh elf. • Dri ve mounting screws i nto the wall.
2.2 Inst allation of the Hybrid IP-PBX Installation Manual 63 2. Hook the sh elf ont o the met al bracket, making sure th at the shel f slides down and ont o the hoo ked par ts of the metal brack e t. Use 2 s crews (B) to fix both s ides of th e shelf.
2.2 Install ation of the Hybrid IP-PBX 64 Installation Manual 2.2.12 Floor Standing (KX- TD A200 Only) Notes • Do not block the openin gs of the shelf.
2.2 Inst allation of the Hybrid IP-PBX Installation Manual 65 3. Lift the shel f , attach it to the meta l bracket, slide it backwards until it l ocks, and retain it with 2 scr ews (B). 4. Fix the fr ont cover on the shelf (refer to "2.2.3 Opening /Closing the Front Cov er") .
2.2 Install ation of the Hybrid IP-PBX 66 Installation Manual 2.2.13 Surge Protector Installation Overvie w A mass ive electr ical surg e can be c aused if lightn ing s trikes a teleph one ca ble 10 m (33 ft) above ground, or if a teleph one line comes into c ontac t with a power li ne.
2.2 Inst allation of the Hybrid IP-PBX Installation Manual 67 Outsid e Installation If you install a n extension ou tside of the buildin g, the following prec autions a re reco mmende d: a. Install the extension wire unde rground. b. Use a co nduit to protect the wire.
2.2 Install ation of the Hybrid IP-PBX 68 Installation Manual 1. Connect the grounding r od to th e surge p rotector us ing a groun ding wir e with a cr oss-sec tional area of at least 1 .3 mm 2 . 2. Bur y the groundin g rod nea r the p rotector. The grounding wir e sho uld be as shor t as pos sible.
2.3 Inf ormation about the Main Proce ssing Card Installation Manual 69 2.3 I nf ormation about the Main Pr ocessing Car d 2.3.1 MPR Card Function Contains the ma in proc essor for all pr ocesse s, ba.
2.3 Inf ormation about the Main Proce ssing Card 70 Installation Manual • A LITH IUM BA TTER Y IS USED IN THE MPR CARD . THERE IS A RISK OF EXPLOSION IF THE BA TTER Y IS REPLA CED WITH THE I N CORRE C T TYPE. DISPOSE OF USED BA TTERIES A CCORDI NG T O THE MA NUF ACTURER'S INSTR UCTIONS.
2.3 Inf ormation about the Main Proce ssing Card Installation Manual 71 2.3.2 MEC Car d (KX-TD A0105) Function Memo r y expansion c ard to inc rease system data st orage sp ace and d ouble the nu mber of DP Ts, using Digital XDP conn ection. T o be m ounted on the M PR card .
2.3 Inf ormation about the Main Proce ssing Card 72 Installation Manual 2.3.3 RMT Card (KX-TD A 0196) Function Analog modem car d for remote communi cation with the Hybr id IP -PBX.
2.4 Inf ormation about the CO Line Car ds Installation Manual 73 2.4 I nf ormation a bout the CO Line Car ds 2.4.1 LCO T8 Card (KX-TD A0180) and L CO T16 Car d (KX- TD A0181) Function Accessories a nd.
2.4 I nform ati on a bou t th e CO Lin e Cards 74 Installation Manual Pin Assignments Amphenol Connector Note Pin assig nments for the pins 9 to 16 and 34 to 41 are for the LCOT16 card only .
2.4 Inf ormation about the CO Line Car ds Installation Manual 75 2.4.2 CID8 Card (KX-TD A0193) Function 8-por t Caller ID signal ty pe FSK/FSK ( with Call Waiting Call er ID [Visua l Calle r ID])/DTMF .
2.4 I nform ati on a bou t th e CO Lin e Cards 76 Installation Manual 2.4.3 T1 Card (KX-TD A0187) Function 1-por t T1 CO line card . EIA/TIA stand ard com plian t.
2.4 Inf ormation about the CO Line Car ds Installation Manual 77 Pin Assignments RJ45 Connector LED Indications No. Signal Name Level [V] Function 1 RX+ (+ ) Rec eiv e data (+ ) 2 RX- (-) Rec eive dat.
2.4 I nform ati on a bou t th e CO Lin e Cards 78 Installation Manual 2.4.4 PRI23 Card (KX-TD A0290) Function 1-por t ISDN Pri mar y Rate In terface card (23 B channels ).
2.4 Inf ormation about the CO Line Car ds Installation Manual 79 Pin Assignments RJ45 Connector LED Indications No. Signal Name Level [V] Function 1 RX+ (+ ) Rec eiv e data (+ ) 2 RX- (-) Rec eive dat.
2.4 I nform ati on a bou t th e CO Lin e Cards 80 Installation Manual 2.4.5 IP-GW4 Card (KX-TD A0480) Function 4-channe l V oIP gatewa y card. Compli ant with V oIP H.323 V . 2 prot ocol, and ITU-T G. 729a, an d G.723.1 CODEC metho ds. G3 f ax suppo r t.
2.4 Inf ormation about the CO Line Car ds Installation Manual 81 LED Indications Indication Color Description CARD ST A TUS Gr een/Re d Card st atus indi catio n • OFF: P ower Off • Gree n ON: No .
2.4 I nform ati on a bou t th e CO Lin e Cards 82 Installation Manual 2.4.6 IP-GW4E Card (KX-TD A0484) Function 4-channe l V oIP gatewa y card. Compli ant with V oIP H.
2.4 Inf ormation about the CO Line Car ds Installation Manual 83 LED Indications Indication Color Description CARD ST A TUS Gr een/Re d Card st atus indi catio n • OFF: P ower Off • Gree n ON: No .
2.4 I nform ati on a bou t th e CO Lin e Cards 84 Installation Manual 2.4.7 IP-GW16 Card (KX-TD A0490) Function 16-chann el V oIP gatewa y car d. Com pliant wit h V oIP H.
2.4 Inf ormation about the CO Line Car ds Installation Manual 85 LED Indications Indication Color Description CARD ST A TUS Gr een/Re d Card st atus indi catio n • OFF: P ower Off • Gree n ON: No .
2.5 I nform ati on a bou t th e Ex tens ion Ca rds 86 Installation Manual 2.5 Inf ormation about the Extension Car ds 2.5.1 CSIF4 Ca r d (KX-TD A0143) a nd CSIF8 Card (KX-TD A0144) Function CSIF4: 4-p or t CS interface card for 4 CSs. CSIF8: 8-p or t CS interface card for 8 CSs.
2.5 Inf ormation about the Extension Card s Installation Manual 87 Editing the CS Name using the KX-TD A Maintenance Console While programming the Hyb rid IP-P BX, we st rongly reco mmend t hat you in.
2.5 I nform ati on a bou t th e Ex tens ion Ca rds 88 Installation Manual LED Indications Indicati on Color Descrip tion CARD ST A TUS Green/Red Ca rd status indica tion • OFF: P ower Off • Green .
2.5 Inf ormation about the Extension Card s Installation Manual 89 2.5.2 DHLC8 Card (KX-TD A0170) Function 8-po r t di gital h ybrid e xtensi on car d for DPTs, APTs , SL Ts, D SS consol es, an d PT - interf ac e CSs, with 2 power f ai lure transfer (PFT) por ts.
2.5 I nform ati on a bou t th e Ex tens ion Ca rds 90 Installation Manual Pin Assignments Amphenol Connector No. Signal Name Function No. Signal Name Function 1 RA SL T Ring por t 1 2 6 T A SL T Tip p.
2.5 Inf ormation about the Extension Card s Installation Manual 91 LED Indications Indication Color Description CARD ST A TUS Gree n/ Orange/Red Card st atus i ndicatio n • OFF: P ower Off • Gree .
2.5 I nform ati on a bou t th e Ex tens ion Ca rds 92 Installation Manual 2.5.3 DLC8 Car d (KX-TD A0171) Function 8-por t digital extension card for DPTs, DSS c onsoles, and PT -interface CSs.
2.5 Inf ormation about the Extension Card s Installation Manual 93 Pin Assignments Amphenol Connector LED Indications No. Signal Name Fun c tion No. Signa l Name Function 1 Reser ved – 26 Res er ved.
2.5 I nform ati on a bou t th e Ex tens ion Ca rds 94 Installation Manual 2.5.4 DLC1 6 Car d (KX-TD A0172) Function 16-por t dig ital extension card f o r DPTs, DSS c onsoles, an d PT -inter f a ce CSs.
2.5 Inf ormation about the Extension Card s Installation Manual 95 Pin Assignments Amphenol Connector LED Indications No. Signal Name Fun c tion No. Signa l Name Function 1 D2A Data por t 1 (Low) 26 D.
2.5 I nform ati on a bou t th e Ex tens ion Ca rds 96 Installation Manual 2.5.5 SLC8 Card (KX-TD A 0173) Function 8-por t extension car d for SL Ts with 2 power failure transfer (PFT) po r ts.
2.5 Inf ormation about the Extension Card s Installation Manual 97 Pin Assignments Amphenol Connector LED Indications No. Signal Name Fun c tion No. Signa l Name Function 1 RA Ring por t 1 26 T A Tip .
2.5 I nform ati on a bou t th e Ex tens ion Ca rds 98 Installation Manual 2.5.6 EXT -CID Car d (KX-TD A0168) Function Sends Caller ID signa ls to e xte nsion por t s.
2.5 Inf ormation about the Extension Card s Installation Manual 99 2.5.7 SLC16 Card (KX-TD A0174) and MSLC16 Card (KX- TD A0175) Function Accessories a nd User-supplied Items Accesso ries (included): S crews × 2, Ferrite core × 1 User- s upplied (not inc luded): Am phenol connec tor Notes • P anas onic SL T with Mes sage W aitin g Lamp (e.
2.5 I nform ati on a bou t th e Ex tens ion Ca rds 100 Installat ion Manual Pin Assignments Amphenol Connector LED Indications No. Signal Name Function No.
2.5 Inf ormation about the Extension Card s Installation Manual 101 2.5.8 IP-EXT16 Card (KX-TD A0470) Function 16-cha nnel V oIP extension card . Complian t with Panasonic prop r ietar y pr otocol, a nd IT U-T G.
2.5 I nform ati on a bou t th e Ex tens ion Ca rds 102 Installation Manual LED Indications Indicati on Color Descrip tion CARD ST A TUS Green/Red Ca rd status indica tion • OFF: P ower Off • Green.
2.6 Inf ormation about the Other Cards Installation Manual 103 2.6 Inf ormation about the Other Car d s 2.6.1 OPB3 C ar d (KX-TD A0190) Function Option al 3-sl ot bas e card for mount ing a m aximum o.
2.6 I nform atio n ab out t he Ot her Cards 104 Installation Manual 2.6.2 DPH4 Card (KX-TD A0161) Function 4-por t door phone c ard for 4 door pho nes and 4 door openers.
2.6 Inf ormation about the Other Cards Installation Manual 105 Pin Assignments 8-pin T erminal Bloc k 10-pin T erminal Bloc k No. Signal Name Function 1 DP4 Door pho ne 4 tran smit 2 com4 Door pho ne .
2.6 I nform atio n ab out t he Ot her Cards 106 Installation Manual 2.6.3 EIO4 Card (KX-T D A0164) Function 4-por t externa l input/ou tput ca rd. T o b e moun ted on the O PB3 card.
2.6 Inf ormation about the Other Cards Installation Manual 107 Pin Assignments 8-pin T erminal Bloc k 10-pin T erminal Bloc k No. Signal Name Function 1C 4 b C o n t r o l 4 2 C4 a Cont rol 4 c om 3C 3 b C o n t r o l 3 4 C3 a Cont rol 3 c om 5C 2 b C o n t r o l 2 6 C2 a Cont rol 2 c om 7C 1 b C o n t r o l 1 8 C1 a Cont rol 1 c om No.
2.6 I nform atio n ab out t he Ot her Cards 108 Installation Manual External Sen sor P ower to the externa l sensor is provided fro m the EIO4 ca rd and must be grounded through the EI O4 card as ind icated in the di agram below .
2.6 Inf ormation about the Other Cards Installation Manual 109 2.6.4 EC HO16 Card (KX-TD A0166) Function 16-cha nnel car d for echo canc ella tion du ring conferences.
2.6 I nform atio n ab out t he Ot her Cards 110 Installation Manual 2.6.5 MSG4 Card (KX-TD A 0191) Function 4-cha nnel m essage car d. T o be mounted on the OPB3 c ard.
2.6 Inf ormation about the Other Cards Installation Manual 111 2.6.6 CTI-L INK Card (KX-TD A0410) Function Ether n et card for CTI co mmunica tion v ia 10BAS E-T p or t.
2.6 I nform atio n ab out t he Ot her Cards 112 Installation Manual LED Indications Indicati on Color Descrip tion CARD ST A TUS Green/Red Ca rd status indica tion • OFF: P ower Off • Green O N: N.
2.7 Connectio n of Extensions Installation Manual 113 2.7 C onnection of Ex tensions 2.7.1 Ma xim um C abling Distances of the Extension Wiring (T wisted Cab le) Notice The max imum cabling di stance may vary depen ding on the co nditions.
2.7 Connecti on of Extensions 114 Installation Manual " " indica tes that the extension c ard sup por ts the te rm inal. PT -interface CS DPT APT DSS Console SL T DHLC8 Card MSLC16, S LC16, .
2.7 Connectio n of Extensions Installation Manual 115 2.7.2 P aralle l Connection of the Extensio ns Any SL T can be con nected in parall el wit h an AP T or a DPT as follows. Note In additio n to an S L T , an an s wer ing machine, a fax machine or a m odem (PC ) can be conne cted i n parallel with an APT o r a DP T .
2.7 Connecti on of Extensions 116 Installation Manual Using an EXtr a Device P ort With KX -T7600 Series DPT With Other DPT T o DHLC8 card DPT SL T T o DHLC8 card To S LT 2-conductor wiring cord Connect pins "T" and "R". 4-conductor wiring cord Connect pins "T", "R", "D1" and "D2".
2.7 Connectio n of Extensions Installation Manual 117 2.7.3 Digital EXtra Device P o r t (Digital XDP) Connection A DPT can be connec ted to ano ther DPT on the Digital XDP co nnecti on. In add ition, if the DPT is co nnect ed to a DH LC8 card, it ca n also hav e an SL T con nected in P ara llel m ode or X DP mod e.
2.7 Connecti on of Extensions 118 Installation Manual Using an EXtr a Device P ort SL T Master DPT Slave DPT 4-conductor wiring cord Connect pins "T", "R", "D1" and "D2". 2-conductor wiring cord Connect pins "T" and "R".
2.7 Connectio n of Extensions Installation Manual 119 2.7.4 First P ar ty Ca ll Control CTI Connection CTI con nection b etween a P C and a KX -T7633/ T7636 DP T provides fir st par ty call c ontrol. The CTI connec tion is m ade v ia a USB i nterface (version 2.
2.8 Conn ection of 2.4 GHz Portable Stations 120 Installation Manual 2.8 Connection of 2.4 GHz P or table Stat ions 2.8.1 Overview The following equipm ent is required t o conn ect the wireless system: CS: Cell Station (KX-TD A0142/KX- T0141) KX-TD A014 2 Using a CS IF Card This u nit deter mines the area cov e red by the wi rele ss syst em.
2.8 Conne ction of 2.4 GHz P ortable Station s Installation Manual 121 Please take into c onsiderati on the dista nce betwee n the CSs when s ite planni ng.
2.8 Conn ection of 2.4 GHz Portable Stations 122 Installation Manual 2.8.2 Procedure Overvie w When c onnec ting the wireles s sys tem, us e extreme car e in cond ucting the si te su r ve y . An inco rrectly perform ed si te sur v ey ca n result in poo r se r vice ar ea, fr equent noise, and di scon nection o f call s.
2.8 Conne ction of 2.4 GHz P ortable Station s Installation Manual 123 4. Finish the site surve y Refer to "2.8.6 A fter Site Sur vey". a. Retur n al l DIP s w itches of each CS to t he OFF po sitio n, and s top supp lyin g power . b. T ur n off th e PS.
2.8 Conn ection of 2.4 GHz Portable Stations 124 Installation Manual 2.8.3 Site Planning Choosi ng the best si te for th e CS require s careful planni ng and testing of es sential areas. The best locat ion may not always be conv en ient for inst allati on.
2.8 Conne ction of 2.4 GHz P ortable Station s Installation Manual 125 Object Materi al T rans missi on T endency W all Co ncrete Th e thicker they are, the le ss radio wav es penetrate the m. Ferroconcrete Radio wav es ca n penetrat e them, but the more i ron there is, the more radio wav es a re refle cted.
2.8 Conn ection of 2.4 GHz Portable Stations 126 Installation Manual CS Co verage Area The example be low shows the s ize of the coverage area of 1 C S if it is in stall ed in an ar ea with no obs tacle s. Note Radio si gnal streng th lev el s are m easured duri ng the si te sur vey (refer to "2.
2.8 Conne ction of 2.4 GHz P ortable Station s Installation Manual 127 one CS bec omes weak . Howe ver , if a PS moves aw ay from a CS an d there ar e no CSs available for handov er , the PS may go out of range and the call could be lo st.
2.8 Conn ection of 2.4 GHz Portable Stations 128 Installation Manual 2.8.4 Before Site Survey Setting and Installing th e CS T em porarily f or Site Sur vey 1. Switch th e Radio Signal T est switch from O FF to ON. 2. Set t he CS n umber s wit ches as de sired.
2.8 Conne ction of 2.4 GHz P ortable Station s Installation Manual 129 3. After se tting th e DIP switch, con nect an AC adaptor or batter y box to the CS us ing a p ower supply adaptor . Note The AC adaptor should be conne cted to a ver ticall y or iented or floor-mo unted AC outlet .
2.8 Conn ection of 2.4 GHz Portable Stations 130 Installation Manual 2.8.5 Site Surv ey The P S has a Ra dio S ignal T est mo de that m onitor s the s tate of th e radio li nk to the CS. After in stall ing the CSs tem porari ly , set the PS to Ra dio Signa l T e st mode and mea sure each CS cover a ge are a.
2.8 Conne ction of 2.4 GHz P ortable Station s Installation Manual 131 2. Measure the radio sig nal st rength by moving towards and awa y from the CS. a.
2.8 Conn ection of 2.4 GHz Portable Stations 132 Installation Manual b. Overlap the CS coverage areas of at l east 2 CSs at any lo catio n in the insta llati on site. c. Make sure that the radi o signal streng th lev el i s greater than "3" at any loc ation in the se r vic e area required by the user .
2.8 Conne ction of 2.4 GHz P ortable Station s Installation Manual 133 Deleting the Stored Scan Data Using the KX-TD7680 Using the KX-TD7690 Press 1, 9, and POWER for more than 2 seconds. 0 to 9, or # for all data Scan Data No. 1 9 T o the Desired Scan Data No.
2.8 Conn ection of 2.4 GHz Portable Stations 134 Installation Manual 2.8.6 After Site Survey After o btaining the pr oper meas urement resu lts, ex i t Radi o Signal T est mode b ef o re conn ecting the CS to the Hybr id IP -PBX. 1. K eep pr essing the POWER button on the PS un til the P S is tur ned OFF .
2.8 Conne ction of 2.4 GHz P ortable Station s Installation Manual 135 2.8.7 C onnecting a Cell Station to the Hybrid IP-PBX Using a CSI F Card Refer to the following e xam ple to c onnect a CS to th e Hybr id IP- PBX.
2.8 Conn ection of 2.4 GHz Portable Stations 136 Installation Manual Using a DHLC/DLC Card Refer to the follo w ing example to connect a CS to t he Hybr id I P-PBX.
2.8 Conne ction of 2.4 GHz P ortable Station s Installation Manual 137 Connecting the CS 1. Connect the cable from the CS IF/DHLC/DLC card to the CS. 2.
2.8 Conn ection of 2.4 GHz Portable Stations 138 Installation Manual Registering the PS The P S must be r egister ed to the Hybr id IP -PBX be f o re it ca n be us ed. Pr ogramming of both the PS a nd Hybr id IP- PBX is requ ired . A P T with multil ine d isplay (e.
2.8 Conne ction of 2.4 GHz P ortable Station s Installation Manual 139 PS Registratio n When the PS h as not bee n regis tered yet When reg ister ing t he PS for the fir st time, it is pos sible to select the des ired langu age for the displ a y . (Y ou do not nee d to ente r the PS system programming mode wh en regis ter ing for the firs t time.
2.8 Conn ection of 2.4 GHz Portable Stations 140 Installation Manual Setting the System Loc k When a s ystem l ock has been set, th e syste m lock password will be re quired for PS syste m setting . Using the KX-TD7680 Using the KX-TD7690 Choose "Enable/Disable".
2.8 Conne ction of 2.4 GHz P ortable Station s Installation Manual 141 Setting the P erson al Identification Number (PIN) f or PS Registration T o pr ev ent re giste ring the P S to a wrong Hybr id I P-PBX, a PIN for PS registrati on ca n be set to th e Hyb r id IP-PBX.
2.8 Conn ection of 2.4 GHz Portable Stations 142 Installation Manual PS T erminati on Confir m the following before cancelin g the PS r egistration: • The PS is tur ned on.
2.8 Conne ction of 2.4 GHz P ortable Station s Installation Manual 143 2.8.8 W all Mounting 1. Place the reference f or wall mount ing (on the follo w ing page) on the wall to mar k the 2 screw positi ons. 2. Install th e 2 sc rews and washer s (inc luded) i nto the wall .
2.8 Conn ection of 2.4 GHz Portable Stations 144 Installation Manual Reference for W all Mounting Please c opy this page and use as a reference for w al l mou nting.
2.9 Connection of Do orphones, Door Opener s, External Senso rs, and Externa l Relays Installation Manual 145 2.9 C onnection of Doo rphones, Door Opener s, Externa l Sensors, and Ext ernal Relays 2.
2.9 Connecti on of Doorphones, Door Openers , External Sensor s, and External Rela ys 146 Installation Manual 2. P ass the wires through the hole i n the base c ov e r , and attac h the base c over to a wall using 2 sc rews. Note T wo kinds of sc rews are incl uded w ith a KX-T308 65.
2.9 Connection of Do orphones, Door Opener s, External Senso rs, and Externa l Relays Installation Manual 147 2. Attach the ter mi nal blocks to the co nnecto rs of the DPH4/E IO4 card on the Hy brid IP-P BX.
2.10 Connec tion of Pe ripherals 148 Installation Manual 2.10 Connection of P eripher als 2.10.1 Connection of P erip herals BGM/MOH The Hybr i d IP-PBX p rovides Background Mu sic and Musi c on Hold. Up to 2 exter nal mus ic sourc es (e.g., user-s uppli ed radios) c an be c onnected to the H ybr id I P-PBX .
2.10 C onnection of P eripheral s Installation Manual 149 Pa g e r Up to 2 pag ing devices ( user- supplied ) ca n be co nnecte d to the Hybr id IP -PBX. CA UTION Exter na l P agi ng Jacks are SEL V por ts a nd sho uld only be con necte d to app rov ed SEL V devices.
2.10 Connec tion of Pe ripherals 150 Installation Manual For con necting a printer/P C with a 25-pin RS-232C connecto r RS-232C Signals • Receive Data (RXD): …(input) Conv eys sign als from the pr i nter or t he PC. • T r ansmit Data ( TXD): …(out put) Conv eys si gnals fr om the unit to the pr inter o r the P C.
2.10 C onnection of P eripheral s Installation Manual 151 PC/CT I Ser ver (via USB version 2. 0) The Hy brid IP-PBX is equi pped wi th a USB i nterface. This in terf a ce provide s co mmunication between th e Hybri d IP-PB X and a P C or a CT I ser ver .
2.11 P ower F ailure Connecti ons 152 Installation Manual 2.11 P ower F ailure Conn ections 2.11.1 P o wer Failure Connections When t he power su pply to the Hybr id I P-PBX fails, power failure transfer (PFT) wil l switch from the c urrent connec tion to the P ower F ail ure Conne ction .
2.11 P ower Fa ilure Connections Installation Manual 153 RJ11 Connector Pin Assignments f or CO line Card PFT P orts 1 and 2 PFT P orts 3 and 4 (for LCO T16 car d only) RJ11 Connector Pin Assignments f or Extension Card PFT P orts 1 and 2 PFT P orts 3 and 4 (f or MSLC16/SLC16 card onl y) No.
2.12 Starting the Hybrid IP-PBX 154 Installation Manual 2.12 Star ting the Hybrid IP- PBX 2.12.1 Start ing the Hybrid IP-PBX CA UTION • SD Memor y Card must be ins er t ed in th e SD Me mor y C ard slo t of the M PR card before star tup.
2.12 Starting the Hybrid IP-PBX Installation Manual 155 2. Plug the AC power cord int o the Hyb rid I P-PBX a nd an AC outlet, and tur n on the Hybr id IP- PBX. Th e R UN in dicato r will f lash. Note F or s afety reasons, do not s tretch, b end, or pi nch the AC power cord.
2.12 Starting the Hybrid IP-PBX 156 Installation Manual Conf irmin g the CO Li ne Connect ion After ini tiali zatio n, program the Hybr id IP-P BX an d connec t CO line s to the Hybr id IP -PBX.
Installation Manual 157 Section 3 Guide f or the KX-TD A Maintenance Console Explai ns the ins tall ation p rocedure, str uc ture, and bas ic informati on of th e KX-T D A M ainten ance Cons ole.
3.1 Overvie w 158 Installation Manual 3.1 Ove r vie w 3.1.1 Overview KX-TDA Maintenance Consol e is des igned to ser ve as an overall system programming reference for the Hybr id IP- PBX. T o program and adminis ter th e Hybr id IP- PBX by PC, y o u need t o install the K X-TDA Mainten ance Cons ole on to the PC.
3.2 Conn ection Installation Manual 159 3.2 Connection 3.2.1 Connecti on Serial Interface Connection Note F or pin ass ignments and m aximum cabling dista nce, refer to "2.10.1 Con nectio n of P e riph erals". LAN Connection vi a CTI-LIN K Car d Note F or pin ass ignments and m aximum cabling distanc e, refer to "2.
3.2 Conn ection 160 Installation Manual External Modem Connection After con necti ng the Hybr id IP -PBX and the e x ter nal modem, set the power s wit ch of th e externa l mode m to "ON", th en the exter nal m odem wi ll be in itial ized with the d efault values.
3.3 Insta llation of the KX-TD A Maintenan ce Console Installation Manual 161 3.3 I nstalla t ion of the KX-TD A Maintenance Console 3.3.1 Ins talling a nd Star ting the KX-T D A Maintenance Co nsole .
3.3 Install ation of the KX-TD A Maintena nce Console 162 Installation Manual Starting the KX-TD A Maintenance C onsole and Assigning the Basic Items (Q u ic k Setup) When you star t the KX-TDA Mainte.
3.3 Insta llation of the KX-TD A Maintenan ce Console Installation Manual 163 7. Follow the instr uctio ns of t he wiz ard and a ssign th e basi c items ( Quick Set up). The program menu appea rs. Y ou ma y now begi n programming t he Hybr id IP-PB X.
3.3 Install ation of the KX-TD A Maintena nce Console 164 Installation Manual Notes • Duri ng a l ong pr ogramming se ssion, it is highl y recom mended that you per iodi call y sav e the system dat a to the S D Memor y Card.
Installation Manual 165 Section 4 T r oub leshooting This sec tion p rovides infor mation on the Hybr id I P-PBX and telephone troublesh ooting ..
4.1 T roub leshooting 166 Installation Manual 4.1 T r oublesh ooting 4.1.1 Installation PROBLE M PROB ABLE CA USE SOLUTION Extensi on doe s n ot operat e. Ba d extension c ard. • Exchang e the car d for a known working one . Bad conn ectio n between th e Hybr id IP-P BX an d telep hone.
4.1 T roub leshooting Installation Manual 167 The ALAR M indic ator on the front of the shelf tur n s on red . A majo r sys tem er ror oc curs i n the Hybr id IP-PBX . • See the error log usin g the K X-TDA Mainten ance Cons ole (re f e r to "4.
4.1 T roub leshooting 168 Installation Manual 4.1.2 Connection Connection between the Hybrid IP-PBX and a PT: Connection between the Hybrid IP-PBX and an SL T: Connection between the Hybrid IP-PBX and an SL T that is polar ity-sensitive: CA USE The T/R is connected to the D1/D2.
4.1 T roub leshooting Installation Manual 169 Connection between the central office and the Hybrid IP-PBX: CA USE CO line is connected to the T2/T1. CO line is connected to the T2/R1. SOLUTION Reconnect the CO line to the T1/R1 or T2/R2 of the telephone jack using 2-conductor wiring.
4.1 T roub leshooting 170 Installation Manual 4.1.3 Operation PROBLE M PROB ABLE CA USE SOLUTION • When us ing the speaker phone on an A PT , nothing i s aud ible.
4.1 T roub leshooting Installation Manual 171 • PS st ay s out of service when the CS status is changed from Out of Ser v ice to In Ser vice. • It may take about 20 s for CS to sta r t up after the status ha s been chang ed to In Ser vice. • W ait unt il the CS s tar ts up.
4.1 T roub leshooting 172 Installation Manual 4.1.4 Using th e Reset Button If the Hyb r id IP-P BX does not ope rate proper ly , use the Res et But ton. Be f o re using the Res et But ton, tr y the sy stem feature agai n to co nfir m whe ther ther e definit ely i s a problem o r not.
4.1 T roub leshooting Installation Manual 173 4.1.5 T roub les hootin g b y Error Log When a m ajor sy stem e rror occur s in t he Hybr id IP- PBX, the A LARM i ndicator on the fr ont of the shelf tur ns on red, and the system logs t he error informa tion.
4.1 T roub leshooting 174 Installation Manual 5 Sub Code Fi v e -digi t sub code (1XXYY ) 1: S helf n umber XX: Slot number KX-TDA100: 00 to 06 ( 00: MPR s lot; 01 to 06: F r ee slot) KX-TDA200: 00 to.
4.1 T roub leshooting Installation Manual 175 List o f Errors and Solu tions The tables below list the error s and thei r solu tions. When an error whose error code is ind icate d with "* " oc curs in the Hybr id I P-PBX, the ALA RM ind icato r on the fron t of the she lf tur ns on red, a nd the s ystem l ogs the er ror infor mation .
4.1 T roub leshooting 176 Installation Manual System Start-up and On-line Operation 220 Flas h ROM access err or • Detection of acces sing err or to Flash ROM of option al ser v ice c ard • See if.
4.1 T roub leshooting Installation Manual 177 011* DC power down • AC power do wn • P ower suppl y circ uit (PSU, back board) ma lfunc tion • Dete ction of over current (shor t circ uit on o pti.
4.1 T roub leshooting 178 Installation Manual 023 Sy stem data file v e rsion e rror • Old system fi les on S D Memor y Ca rd • Defectiv e sy stem files on SD Memor y Ca rd • Restore the backup .
4.1 T roub leshooting Installation Manual 179 041* Ex pansi on Memor y Ca rd Fa i l u r e • MEC c ard is not p roper ly conne cted • See if th e corre sponding option al ser vic e car d is in stal.
4.1 T roub leshooting 180 Installation Manual 231 LP R alive check error • Optiona l ser v ice card malfunction : DHLC, DLC , CSIF , T1, PRI, OPB3, CTI- LINK, IP-G W , SLC8, IP- EXT , LCO T • Back.
4.1 T roub leshooting Installation Manual 181 310* P or t Link F ailur e • V oice Pr ocessi ng Syst em malfu nction • P or ts defective on optio nal ser v ice car d: DHLC, DLC • Check the V oice.
4.1 T roub leshooting 182 Installation Manual 355 IP -unit al ive ch eck error • Optiona l ser v ice card malfun ction : IP-E XT • The IP-E XT car d will b e rebo oted automati cally if the error .
4.1 T roub leshooting Installation Manual 183 372 NDSS messag e over I PG W not ificatio n - caused by IPG W Tx reso urce limitati on • Optio nal s er vic e card malf unction: IP-GW • Ignore i f n.
4.1 T roub leshooting 184 Installation Manual 396 IP -GW Run • IP -GW is star ted from a remote m aintena nce PC • This i nforma tion is logge d when IP- GW is sta r ted from a re mote ma intena n.
Installation Manual 185 Section 5 Appendix.
5.1 R evis ion H ist or y 186 Installation Manual 5.1 Revi sion History 5.1.1 PMPR Software File V er sio n 1.1xxx Ne w Options • System Comp onents T able New Contents • 2.7.3 Di gital EXtra Device P or t (Digital XDP) Con nection Change d Contents • 1.
5.1 Re vision History Installation Manual 187 5.1.2 PMPR Software F ile V ersion 2.0xxx Ne w Options • System C omponen ts T able Changed Co ntents • 1.
5.1 R evis ion H ist or y 188 Installation Manual 5.1.3 PMPR Software File V er sio n 3.0xxx Change d Contents • 1.4.3 S ystem Cap acity • 3.3.1 In stall ing and S tar ting the K X-TDA Maintenance.
Installation Manual 189 Inde x.
Index 190 Installation Manual Numerics 16-Chan nel Ec ho C anceller Ca rd (KX-TD A0166) 25, 109 16-Chan nel Vo IP Extens ion C ard (K X-TD A0470 ) 26, 10 1 16-Chan nel VoIP Ga teway Card (KX-TDA 0490).
Index Installation Manual 191 K KX-TD A Maint enanc e Console, Connec tion 159 KX-TD A Main tenanc e Cons ole, Ins tallatio n 161 KX-TD A Mai ntena nce Cons ole, Ove rview 158 KX-TD A Maint enance Con.
Index 192 Installation Manual TDA09 20) 26, 69 Sit e Plann ing, 2. 4 GHz Por tabl e Stati on 124 Site Survey, 2.4 GHz Port able Sta tion 130 Slave DPT, Digi tal XDP 117 SLC16 Card (KX-TDA017 4) 99 SLC.
Index Installation Manual 193.
Panasonic Consumer Electronics Company, Division of Panasonic Corporation of North America One Panasonic Way, Secaucus, New Jersey 07094 Panasonic Puerto Rico, Inc. San Gabriel Industrial Park, Ave. 65 de Infantería, Km. 9.5, Carolina, Puerto Rico 00985 http://www.
Un punto importante, dopo l’acquisto del dispositivo (o anche prima di acquisto) è quello di leggere il manuale. Dobbiamo farlo per diversi motivi semplici:
Se non hai ancora comprato il Panasonic KX-TDA100 è un buon momento per familiarizzare con i dati di base del prodotto. Prime consultare le pagine iniziali del manuale d’uso, che si trova al di sopra. Dovresti trovare lì i dati tecnici più importanti del Panasonic KX-TDA100 - in questo modo è possibile verificare se l’apparecchio soddisfa le tue esigenze. Esplorando le pagine segenti del manuali d’uso Panasonic KX-TDA100 imparerai tutte le caratteristiche del prodotto e le informazioni sul suo funzionamento. Le informazioni sul Panasonic KX-TDA100 ti aiuteranno sicuramente a prendere una decisione relativa all’acquisto.
In una situazione in cui hai già il Panasonic KX-TDA100, ma non hai ancora letto il manuale d’uso, dovresti farlo per le ragioni sopra descritte. Saprai quindi se hai correttamente usato le funzioni disponibili, e se hai commesso errori che possono ridurre la durata di vita del Panasonic KX-TDA100.
Tuttavia, uno dei ruoli più importanti per l’utente svolti dal manuale d’uso è quello di aiutare a risolvere i problemi con il Panasonic KX-TDA100. Quasi sempre, ci troverai Troubleshooting, cioè i guasti più frequenti e malfunzionamenti del dispositivo Panasonic KX-TDA100 insieme con le istruzioni su come risolverli. Anche se non si riesci a risolvere il problema, il manuale d’uso ti mostrerà il percorso di ulteriori procedimenti – il contatto con il centro servizio clienti o il servizio più vicino.