Remote Operation Panel AW-CB400L

please read these instructions completely.

Safety precautions
UNSCREWING. To reduce the risk of electric shock, do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel.
A warning that an apparatus with CLASS I construction shall be connected to a MAINS socket outlet with a protective earthing connection.
1 indicates safety information.


≥Handle the ROP carefully.
Dropping the ROP or subjecting it to strong impact may give rise to malfunctioning or accidents.
≥Use the ROP in an ambient temperature of –10°C to +45°C.
Using the ROP in cold places below –10°C or hot places above 45°C may adversely affect its internal parts.
≥Turn off the power before connecting or disconnecting the cables.
Be absolutely sure to turn off the power before connecting or disconnecting the cables.
Wipe the ROP using a dry cloth. To remove stubborn dirt, dip a cloth into a diluted solution of kitchen detergent, wring it out well, and wipe the ROP gently.
<Caution> ≥Avoid using benzine, paint thinners and other volatile fluids. ≥If a chemical cleaning cloth is to be used, carefully read through the precautions for its use.
≥Maintenance

3 4 2 1
: ;
G
H
A
B
J
1TALLY lamps [1] to [5] When tally signals are supplied to the (L) tally/INCOM connectors [1] to [5] on the rear panel, the lamps with the numbers corresponding to those connectors light up. When tally signals are supplied to the tally connectors [1] to [5] of the pan/tilt control panel, if this control panel is connected to the ROP, the lamps with the numbers corresponding to those connectors also light up.
4MENU button Press this to turn the setting menu ON or OFF.
5LCD panel This displays the current settings.
6CAM CONTROL buttons [1] to [5] If the cameras are connected directly to the ROP, the button lamps corresponding to numbers of the buttons selected light, and the selected cameras can be controlled by pressing buttons [1] to [5]. If the ROP is connected to the pan/tilt control panel for use, the cameras installed to the pan/tilt head which is connected to the pan/tilt control panel can be selected. The buttons corresponding to the selected numbers light, and selected cameras can be controlled. When the ROP is connected to the pan/tilt control panel, the camera selection function can be set to “From pan/tilt control panel only”, “From ROP only” or “From both”, depending on the setting selected by the pan/tilt control panel. For further details, refer to the instruction manual of the pan/tilt control panel.
2LCD CONTRAST control Use this to adjust the contrast of the LCD panel.
3DATA SET button Press DATA SET button and (6) CAM CONTROL buttons [1] to [5] at the same time to synchronize the setting data stored in the cameras selected with the setting data stored in the ROP or vice versa. Press only DATA SET button to synchronize the setting data stored in all cameras connected to the ROP.
≥In the case of the AW-E300, AW-E300A, AW-E600 or
AW-E800A cameras, the data stored in the ROP is transferred to the cameras. In the case of the AW-E350, AW-E650, AW-E655 or AW-E750 cameras, the data stored in the cameras is transferred to the ROP. Data transfer takes two to three or so minutes.
≥Press this button when the ROP is used for the first
time, or when the camera is replaced.

7DTL button Each time this is pressed, the detail is switched from ON to OFF or vice versa. While the detail is ON, the button lamp is lit; while it is OFF, the button lamp is off. The setting while the detail is ON is set using the menu.
Use this to select the camera’s video output signals. Each time it is pressed, the camera signals are switched from colour bar signals to video signals or vice versa. While colour bar signals are selected, the button lamp is lit; while video signals are selected, it is off.
8SCENE FILE buttons [USER/1/2/3] Use these to select the scene files of the camera.
Use these to select the white balance adjustment mode. ATW: When the ATW button is pressed, the automatic
9GAIN buttons [0dB/L/M/H/AGC] Use these to set the camera gain. The gain-up function can be set to one of four levels using the GAIN 0dB, L, M and H buttons. The gain-up amount can be set for the L, M and H buttons each using the respective menus. When the AGC button is pressed, AGC is activated, and the gain is adjusted automatically in accordance with the light quantity. The maximum AGC gain can be set using the menu.
adjustment mode is established for the white balance, and the ATW button lamp lights. A: When the A button is pressed, the white balance registered in the camera’s AWC A memory is established, and the A button lamp lights. When the (;) AWC button is pressed after pressing the A button, the white balance is automatically adjusted and registered in the camera’s AWC A memory. B: When the B button is pressed, the white balance registered in the camera’s AWC B memory is established, and the B button lamp lights. When the (;) AWC button is pressed after pressing the B button, the white balance is automatically adjusted and registered in the camera’s AWC B memory.
:ABC button
Press this button to adjust the black balance automatically. While the black balance is being adjusted, the button lamp flashes; when the adjustment is completed, it goes off. It lights if the black balance could not be adjusted.
≥The ABC button does not work when colour bars have
>R/B GAIN dials
been selected by the (
These enable the white balance to be adjusted manually after selecting the A or B button among the (=) ATW/A/B buttons and the white balance has been automatically adjusted by pressing the (;) AWC button. When exercising control over the AW-E350, AW-E650, AW-E655 or AW-E750, the change of setting value in the dial’s setting can be switched from “large” to “small” or vice versa by pressing the CONT dial.
When this button is pressed while the A or B button among the (=) ATW/A/B buttons is selected, the white balance is automatically adjusted, and the adjustment is registered in the camera’s AWC A or AWC B memory. While the white balance is being adjusted, the AWC button lamp flashes, and when it is adjusted properly, it goes off. It lights if the white balance could not be adjusted.
?R/B PED dials
These enable the black balance to be adjusted manually after the black balance has been automatically adjusted by pressing the (:) ABC button. When exercising control over the AW-E350, AW-E650, AW-E655 or AW-E750, the change of setting value in the dial’s setting can be switched from “large” to “small” or vice versa by pressing the CONT dial.
≥The AWC button does not work when colour bars have
been selected by the (
screen does not show an image with a white object.
@OPTION SW [A to D] buttons
Refer to “Menu settings” for details on the items which can be set in these OPTION SW buttons.

This enables the total pedestal of the cameras to be set. When exercising control over the AW-E350, AW-E650, AW-E655 or AW-E750, the change of setting value in the dial’s setting can be switched from “large” to “small” or vice versa by pressing the CONT dial.
The INCOM (inter-communication) headset is connected here.
Use this to adjust the volume of the headset’s receiver.
BIRIS [AUTO/MANU/LOCK] button
Use this to select the method for adjusting the lens iris of the cameras selected by the CAM CONTROL buttons. Each time it is pressed, the setting is switched in the sequence of AUTO, MANU and LOCK. AUTO: The cameras automatically adjust the lens iris in
When this button is pressed, the buzzer of the connected controller sounds, and the button lamp lights.
The lens iris can be adjusted by turning this dial while the (B) IRIS [AUTO/MANU/LOCK] button is set to MANU. The iris is opened by turning the dial clockwise and stopped by turning it counterclockwise. By pressing the (C) CONT dial, the response speed can be switched from “fast” to “slow” or vice versa.
accordance with the light quantity, and the button lamp lights. MANU: The lens iris is adjusted manually using the (I)
IRIS dial. At this setting, the button lamp is off. LOCK: The lens iris is locked at the manually adjusted
setting. It cannot be adjusted even by turning the (I) IRIS dial. When the (I) IRIS dial is turned, the button lamp flashes to indicate that the lens iris cannot be adjusted. When the ROP is connected to the pan/tilt control panel, the lens iris control can be set to “From pan/tilt control panel only”, “From ROP only” or “From both”, depending on the setting selected by the pan/tilt control panel. For further details, refer to the instruction manual of the pan/tilt control panel.
When the response speed of the (I) IRIS dial is at “fast”, this lamp lights up; when it is at “slow”, the lamp is off.
Use this for menu setting operations.
When the (E) OPERATE switch is at ON, this lamp lights up green; when it is at OFF, the lamp is off.
EOPERATE [OFF/ON] switch
Camera control is enabled by setting this switch to ON.
When the ROP is connected to the pan/tilt control panel, camera control is not possible unless the OPERATE switch on the pan/tilt control panel is set to ON.

M
N
O
K CONTROL OUT TO CONTROL PANEL
MCONTROL OUT TO CAMERA connectors
connector When connecting the pan/tilt control panel for operation, connect this connector to the CAMERA CONTROL IN FROM ROP connector on the pan/tilt control panel using the control panel’s connecting cable. The cameras are then controlled through the pan/tilt control panel.
[1] to [5] Connect these to the convertible cameras. Use the connecting cables (optional accessory) AW-CA50T8 or AW-CA50T9 + RS-422/RS-232C converter to connect these connectors to the I/F REMOTE connectors on the convertible cameras.
NDC 12V IN socket
Connect this to the TALLY/INCOM connector on the video switcher or other units. When the TALLY connector is set to the GND level, the (1) TALLY lamp lights. Do not apply a voltage in excess of 5V to this connector.
Connect the AW-PS505 AC adaptor (optional accessory) to this socket. When the ROP is connected to the pan/tilt control panel using the pan/tilt control panel connecting cable, power will be supplied to the ROP from the pan/tilt control panel.
Connect this terminal to ground.
87654321 ?>=
Pin layout as seen from the
back panel of AW-CB400
Use the accessory tally/INCOM connector (D-SUB 15-pin) to connect the tally/INCOM signals to the system. Connect a 4-wire INCOM system to the INCOM connector. When the ROP has been connected to the pan/tilt control panel, the tally/INCOM functions of the ROP and the pan/tilt control panel will be executed if the tally/INCOM signals are connected to the ROP or the pan/tilt control panel.
LTALLY/INCOM connector · OGrounding terminal

$ When connecting the ROP in a system that includes pan/tilt heads, pan/tilt control

AW-CA50T8 or AW-CA50T9 + RS-422/RS-232C converter
AW-PS505
AW-CB400
Cable provided with AC adaptor

$ When connecting the ROP in a system that includes pan/tilt heads, pan/tilt control


When a pan/tilt head system and cameras have been connected to the CONTROL OUT connectors on the pan/tilt control panel and the CONTROL OUT connectors with the corresponding numbers on the ROP, the camera control exercised by the pan/tilt head system connected to the CONTROL OUT connectors on the pan/tilt control panel takes priority, and the camera connected directly to the ROP cannot be controlled.
❈For details on how to connect the pan/tilt heads and pan/tilt control panel, refer to the instruction manual provided with
the pan/tilt control panel.

$ When the distance between the ROP and the pan/tilt control panel is more than 10 meters
The distance between the ROP and the pan/tilt control panel can be extended up to a maximum of about 1000 meters on the following condition using the provided cable (refer following specifications) and/or equivalent cables. (Prepare the cables of required length.)


Ferrite core Ferrite core
Use the twist pair cables.

Japan Aviation Electronics Industry, Ltd. Connector: D02-29PF-N-F0 Contact: D02-22-26P-PKG100 (For AWG 26 to 28) Case: DA-C4-J10
Japan Aviation Electronics Industry, Ltd. Connector: D02-29SF-N-F0 Contact: D02-22-26S-PKG100 (For AWG 26 to 28) Case: DA-C4-J10
Connector used · Connector used

Turn on the power. First set the power switch on the AC adaptor used for the ROP and the AC power switches on the cameras to ON, and set the OPERATE switch on the ROP to ON.
For details on providing cable compensation for the cameras, refer to the instruction manual provided with the cable compensation unit.
If the cameras are to be used in the genlock mode, phase adjustment is required in order to adjust the phases between the cameras and other units. Genlock adjustment is not needed if genlock is not going to be used.
1 Select the first camera to be adjusted by pressing the CAM CONTROL button.
2 Press the MENU button, and display the camera setting menu on the LCD panel.
3 Turn the CONT dial, and display the G/L SETTING menu.
4 Push the CONT dial straight down, and display H PHASE on the bottom line of the LCD.
5 Observe the waveforms of the genlock signal (black burst signal or video signal (VBS)) and video signal output on an oscilloscope, and adjust the CONT dial in such a way that the horizontal phase is adjusted as shown in the figure below.
External sync (genlock) signal input (black burst signal)
Adjust the horizontal phase here.
6 Select the next camera by pressing the CAM CONTROL button, and adjust the horizontal phase of the next camera. Repeat this for all the connected cameras.
Video signal output

1 Select the first camera to be adjusted by pressing the CAM CONTROL button.
2 Press the MENU button to display the menu on the LCD panel.
3 Turn the CONT dial to display the G/L SETTING menu.
4 Push the CONT dial straight down twice to display SC COARSE on the bottom line of the LCD. The sub carrier phase can now be adjusted coarsely by turning the CONT dial. When the CONT dial is pushed three times, SC FINE appears, and the sub carrier phase can now be adjusted finely by turning the CONT dial.
5 Keep adjusting the SC COARSE and SC FINE phase so that the sub carrier (colour) phase of the video signal output is aligned with the colours of the programme output (split colour bar output) of the video switcher or other unit that serves as the reference. The colour phase can be adjusted more accurately if a vectorscope is used.
6 Select the next camera by pressing the CAM CONTROL button, and adjust the sub carrier phase of the next camera. Repeat this for all the connected cameras.
Colour bars of camera
Colour bars of special effects unit
This adjustment is performed when the pedestal of a multiple number of cameras is to be brought into alignment.
1 Select the first camera to be adjusted by pressing the CAM CONTROL button.
2 Set the lens iris to manual, and stop it down.
3 Use an oscilloscope or waveform monitor to adjust the pedestal level to correspond to the reference level using the total pedestal dial.
4 Select the next camera by pressing the CAM CONTROL button, and adjust the pedestal of the next camera. Repeat this for all the connected cameras.
Adjust the pedestal level to the reference level.

The GAIN information appears first when the OPERATE switch is set to ON.
1Gain setting The gain of the camera selected by the CAM CONTROL button is set on this display. The analogue gain-up value appears on the right of the top line, and the gain information for the lit GAIN button is displayed. The R gain and B gain settings are shown on the bottom line. When the R or B GAIN dial is turned, the R or B gain is incremented or decremented. The value which can be set differs depending on the camera concerned. The values corresponding to white balance A and B can be stored in the memory. When the automatic adjustment mode (ATW among the ATW, A and B buttons) has been selected for the white balance, “– – –” appears on the display, and the gain cannot be set.
When the MENU button is pressed, the display changes in the sequence shown below, after which the display returns to the gain setting screen.
PEDESTAL T: 0
2Pedestal setting The pedestal of the camera selected by the CAM CONTROL button is set on this display. The total pedestal setting is shown on the top line, and the R pedestal and B pedestal settings on the bottom line. When the R or B PED dial is turned, the R or B pedestal is incremented or decremented. The value which can be set differs depending on the camera concerned.
Z DTL setting (when SCENE FILE is set to the USER mode)
Z DTL setting (when 1, 2 or 3 is set for SCENE FILE)
3DTL setting The horizontal detail and vertical detail of the camera selected by the CAM CONTROL button is set on these displays. When USER is selected for SCENE FILE, any value from 0 to 63 can be set as the H DETAIL and V DETAIL level. Press the CONT switch to switch between H and V. When 1, 2 or 3 is set for SCENE FILE, use the CONT dial to switch between HIGH and LOW.
HIGH
4Camera settings The detailed settings of the camera selected by the CAM CONTROL button are set on these displays. Turn the CONT dial to select the setting item, and press it to display the settings on the bottom line. If the CONT dial is turned while the setting is displayed, the setting can be changed. Upon completion of the setting, press the CONT dial to clear the bottom line display, and another setting item can now be selected.
Z Remote operation panel settings
5Remote operation panel settings The controller settings are set on these displays. Operation is the same as that for “4 Camera settings”.
6Exiting the setting menu Press the MENU button to exit the setting menu.

Item Setting Initial value
A.IRIS LEVEL –50 to +50 0
A.IRIS PEAK/AVG P50 to A50 0
TOP CUT,
BTM CUT, L/R CUT
SHUTTER 1/120, 1/250, 1/500, OFF
SYN-SCAN, ELC
SYNCHRO SCAN
DIGITAL GAIN 0, 6, 12, 18, 24, 30dB 0dB
AGC MAX LEVEL OFF, 6, 12, 18, 24, 30,
N/Eye L, N/Eye H
CHARGE TIME 2S, 1S, 1/2S, 1/4S, 1/8S, 1/15S, OFF
CHROMA LEVEL –3 to +3 0
MIDDLE,
FAST1, FAST2
NEGA/POSI POSI, NEGA POSI
H PHASE –206 to +49 0
SC FINE –511 to +511 0
DETAIL BAND 1 to 5 2
NOISE SUPPRESS 0 to 10 3
LEVEL DEPENDENT 0% to 25% 0%
DARK DETAIL 0 to 5 0
CHROMA DETAIL 0 to 15 0
CORNER DETAIL OFF, ON OFF
PRECISION DTL OFF, ON OFF
MATRIX B_Mg GAIN –127 to +127 0
MATRIX B_Mg PHAS –127 to +127 0
MATRIX Mg GAIN –127 to +127 0
MATRIX Mg PHASE –127 to +127 0
MATRIX Mg_R GAIN –127 to +127 0
MATRIX Mg_R PHAS –127 to +127 0
MATRIX R GAIN –127 to +127 0
MATRIX R PHASE –127 to +127 0
MATRIX R_Yl GAIN –127 to +127 0
MATRIX R_Yl PHAS –127 to +127 0
MATRIX Yl GAIN –127 to +127 0
MATRIX Yl PHASE –127 to +127 0
MATRIX Yl_G GAIN –127 to +127 0
MATRIX Yl_G PHAS –127 to +127 0
1/1000, 1/2000, · 1/4000, 1/10000,

Item Setting Initial value
MATRIX G GAIN –127 to +127 0
MATRIX G PHASE –127 to +127 0
MATRIX G_Cy GAIN –127 to +127 0
MATRIX G_Cy PHAS –127 to +127 0
MATRIX Cy GAIN –127 to +127 0
MATRIX Cy PHASE –127 to +127 0
MATRIX Cy_B GAIN –127 to +127 0
MATRIX Cy_B PHAS –127 to +127 0
MATRIX B GAIN –127 to +127 0
MATRIX B PHASE –127 to +127 0
GAMMA 0.35 to 0.55 0.45
WHITE CLIP 95% to 110% 110%
FLARE R 0 to 100 0
FLARE G 0 to 100 0
FLARE B 0 to 100 0
CLEAN DNR OFF, LOW, HIGH OFF
3D-DNR OFF, LOW, MID, HIGH OFF
2D-LPF OFF, LOW, HIGH OFF
FIELD/FRAME FIELD, FRAME FIELD/FRAME
SIGNAL SELECT R/G/B , Y/Pb/Pr, Y/C Y/Pb/Pr
ZEBRA INDICATOR OFF, ON OFF
ZEBRA LEVEL 70% to 110%
SAFETY ZONE 1, 2, 3, 4, 5, OFF 4
❈Concerning the camera setting items
The functions that can be controlled vary depending on the camera connected. If a camera does not support a particular function, its setting will not take effect even if that function appears on the menu. For details on the functions featured by a specific camera, refer to the camera’s instruction manual.
88% to 98%

$ Items which can be selected on the remote operation panel setting display
Item Setting Initial value
OPTION B NOT USE, TELE, WIDE, FAR, NEAR, AF NOT USE OPTION C IR THROUGH, 1/16ND, 1/64ND
BUZZER OFF, ON ON
OPTION A - D settings (NOT USE, TELE, WIDE, NEAR, FAR, AF, IR THROUGH, 1/16ND, 1/64ND)
The following functions can be allocated to the OPTION SW [A] to [D] buttons.
NOT USE: The button’s function is cancelled.
When a convertible camera or AW-E655 camera, into which has been inserted an optional card with the lens I/F card function, has been directly connected to the ROP, it is possible to control the zooming and focusing of the motorized lens. With the TELE setting, the lens is zoomed toward the “TELE” end for as long as the option button is held down. With the WIDE setting, the lens is zoomed toward the “WIDE” end for as long as the option button is held down. With the NEAR setting, the lens is focused toward the “NEAR” end for as long as the option button is held down. With the FAR setting, the lens is focused toward the “FAR” end for as long as the option button is held down.
AF: When a lens provided with the auto focus function is used, the ON and OFF settings of the auto focus function are controlled. Each time the button is pressed, the setting is switched from ON to OFF or vice versa. When the auto focus function is set to ON, the lamp of the button to which this function has been allocated lights; when it is set to OFF, the lamp is off.
IR THROUGH: The motorized filter of the AW-E655 is set to IR THROUGH. When the button is pressed again, it is set to
NORMAL. The lamp of the button lights when the filter is set to IR THROUGH; it is off when another filter is selected.
1/16 ND: The motorized filter of the AW-E655 is set to 1/16ND. When the button is pressed again, it is set to NORMAL. The lamp of the button lights when the filter is set to 1/16ND; it is off when another filter is selected.
1/64 ND: The motorized filter of the AW-E655 is set to 1/64ND. When the button is pressed again, it is set to NORMAL. The lamp of the button lights when the filter is set to 1/64ND; it is off when another filter is selected.
This is used to set for the buzzer inside the remote operation panel to ON or OFF. The buzzer does not sound at the OFF setting. The buzzer sounds when the CALL button is pressed.

<NOTE> ≥The AW-CB400 is 100 mm wide. If it is to be installed in a full-size rack (which accommodates units totaling
420 mm in width), provide panels or other parts to supplement the AW-CB400’s width so that it will fill the rack width-wise. ≥If the AW-CB400 is joined to the AW-RP400, the resulting width will be equivalent to that of the full width of
the rack (which accommodates units totaling 420 mm in width).
1 Remove the rubber caps on the side panels.
2 Use the accessory mounting screws (M4!8 mm) to attach the rack-mounting adaptors. Remove the rubber caps.

Accessory mounting screws (M4!8 mm) 4 pcs
Remove the rubber caps.
Joining the ROP to the AW-RP400 and mounting the joined-up units in a rack
1 Remove the rubber caps on the side panels of the AW-CB400.
2 Attach the accessory join-up screws (stepped screws) to the two places on the side of the ROP which is to be joined to the AW-RP400.
3 Adhere the joining stickers onto the side panels of the AW-RP400 concentrically with the join-up screws.
4 Align the holes of the AW-CB400 with the join-up screws, shift in the direction shown by the arrow, and fit the two units together to make a single integrated unit.
5 Attach the join-up fixture to bottom panels of the AW-RP400 and AW-CB400.
6 Attach the rack-mounting adaptors using the mounting screws (M4!8 mm) provided.
Join-up screws (stepped screws) ❈When the AW-RP400 is to be joined on the left of the AW-CB400.

Mounting screws (accessory) M4!8 mm 4 pcs
Rack-mounting adaptors

The position of the connector panel can be changed from the rear panel to the bottom panel.
Screws (!3)
1 Remove the three screws of the bottom and side panels to remove the blank panel.
Remove the blank panel.
2 Remove the three screws of the rear and side panels to remove the connector panel.
Screws (!3)
3 Secure the blank panel to the rear panel using the screws.
Screws (!3)
4 Remove the two rubber feet of the blank panel.
Attach the blank panel.
Screws (!3)
5 Secure the connector panel to the bottom panel using the screws.
Attach the connector panel.
Connector panel · Rubber feet

1 indicates safety information.
Switch functions: DATA SET, menu, camera control selection, DTL, scene file selection, gain selection, BAR/CAM switching, white balance selection, AWC, ABC, call, lens iris AUTO/MANU/LOCK switching, option switches (1 to 4)
Dimensions (W!H!D): 100!85!266 mm
Weight and Dimensions indicated above are approximate. Specifications are subject to change without notice.
Input connectors · Output connectors · Input/output connectors